Installation Guide

Troubleshooting
17
TROUBLESHOOTING PROCEDURES FOR BREEZE I AND BREEZE II
Issue Cause What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON. 1. Makesurethecircuitbreakerandtheunit’s
power is ON.
2. Thepowerlineandthecablelockingconnector
is not connecting properly.
2. Checkthepowerconnectionwiththeunitis
connected properly.
3. The switch or control board wirings are
disconnected.
3. Makesurethewiringsattheswitchorcontrol
board are connected properly.
4. The wires on control board or switch are loose. 4. Makesurethewiresonthecontrolboardor
switch are connected properly.
5. The switch or control board is defective. 5. Change the switch or control board.
Lightworks,but
blower is not
turning.
1. The blower is defective, possible seized. 1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor. 3. Change the capacitor.
4. The control board or blower switch is defective. 4. Change the control board or blower switch.
The unit is
vibrating.
1. The blower is not secure in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Change the blower wheel.
3. The hood is not secured in place. 3. Checktheinstallationofthehood.
The unit is
whistling.
1.Thelterisnotinthecorrectposition. 1.Adjusttheltersuntilthewhistlingstops.
2. The duct pipe connections are not sealed or
connected properly.
2.Checktheductpipeconnectionstobesureall
connections are sealed properly.
The blower is
working,butthe
lights are not.
1. Defective bulb. 1. Change the bulb.
2. The light bulb is loose. 2. Tighten the light bulb.
3. The light bulb plug is disconnected. 3. Connect the light bulb plug.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cooktop.
1. Adjustthedistancebetweenthecooktopand
thebottomofthehoodwithin24”and32”
range.
2. The wind from the opened windows or opened
doorsinthesurroundingareaarea󰀨ectingthe
ventilation of the hood.
2. Close all the windows and doors to eliminate
theoutsidewindow.
3. Blockageintheductopeningorductwork. 3. Removealltheblockingfromtheductworkor
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
Mesh Filter is
vibrating.
1.Meshlterisloose. 1.Makesurethemetalclipsinthehandleare
notstuck.Orreplacethemeshlter.
2.Filterspingclipisbroken. 2.Uninstallandreinstalllter,pushuponlter
latch.Replacemeshlterifneeded.