TROUBLESHOOTING PROCEDURES FOR BREEZE I AND BREEZE II
Issue Cause What to do
After installation,
the unit doesn’t
work.
1. The power source is not turned ON. 1. Makesurethecircuitbreakerandtheunit’s
power is ON.
2. Thepowerlineandthecablelockingconnector
is not connecting properly.
2. Checkthepowerconnectionwiththeunitis
connected properly.
3. The switch or control board wirings are
disconnected.
3. Makesurethewiringsattheswitchorcontrol
board are connected properly.
4. The wires on control board or switch are loose. 4. Makesurethewiresonthecontrolboardor
switch are connected properly.
5. The switch or control board is defective. 5. Change the switch or control board.
Lightworks,but
blower is not
turning.
1. The blower is defective, possible seized. 1. Change the blower.
2. The thermally protected system detects if the
blower is too hot to operate and shuts the blower
down.
2. The blower will function properly after the
thermally protected system cool down.
3. Damaged capacitor. 3. Change the capacitor.
4. The control board or blower switch is defective. 4. Change the control board or blower switch.
The unit is
vibrating.
1. The blower is not secure in place. 1. Tighten the blower in place.
2. Damaged blower wheel. 2. Change the blower wheel.
3. The hood is not secured in place. 3. Checktheinstallationofthehood.
The unit is
whistling.
1.Thelterisnotinthecorrectposition. 1.Adjusttheltersuntilthewhistlingstops.
2. The duct pipe connections are not sealed or
connected properly.
2.Checktheductpipeconnectionstobesureall
connections are sealed properly.
The blower is
working,butthe
lights are not.
1. Defective bulb. 1. Change the bulb.
2. The light bulb is loose. 2. Tighten the light bulb.
3. The light bulb plug is disconnected. 3. Connect the light bulb plug.
The hood is
not venting out
properly.
1. The hood might be hanging to high from the
cooktop.
1. Adjustthedistancebetweenthecooktopand
thebottomofthehoodwithin24”and32”
range.
2. The wind from the opened windows or opened
doorsinthesurroundingareaareaectingthe
ventilation of the hood.
2. Close all the windows and doors to eliminate
theoutsidewindow.
3. Blockageintheductopeningorductwork. 3. Removealltheblockingfromtheductworkor
duct opening.
4. The direction of duct opening is against the wind. 4. Adjust the duct opening direction.
5. Using the wrong size of ducting. 5. Change the ducting to correct size.
Mesh Filter is
vibrating.
1.Meshlterisloose. 1.Makesurethemetalclipsinthehandleare
notstuck.Orreplacethemeshlter.
2.Filterspingclipisbroken. 2.Uninstallandreinstalllter,pushuponlter
latch.Replacemeshlterifneeded.