Use, Care, and Installation Guide www.zephyronline.com Typhoon AK2100BS, B,W AK2136BS, B,W AK2142BS AK2148BS C TM Airflow Control Technology Hurricane AK2500BS, B, W AK2536BS, B,W C TM Airflow Control Technology Cyclone AK6500BS, B, BS, W AK6536BS, B, BS, W AK6542BS Model number: Serial Number: Date of Purchase: Sales Dealer: JUL18.0401 © Zephyr Ventilation LLC.
INSTALLATION Ductwork Calculation Sheet ................................... Mounting Height & Clearance................................ Ducting Options ........................................................... 6SHFL¿FDWLRQV ............................................................... 3-1/4”x10” Rectangular Ducting Preparation... Preparing Electrical .................................................... Mounting the Range Hood ......................................
Important Safety Notice www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. NOT FOR USE IN OUTDOOR COOKING ENVIRONMENTS. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 90 0 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft. Round, 90 0 elbow x( 6”, 7”, 8”, 10” 9 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mounting height between range top to hood bottom should be no less than 24”. Maximum mounting height should be no higher than 32”. It is important to install the hood at the proper mounting height. Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG ¿UH KD]DUG ZKLOH hoods mounted too high will be hard to reach and ZLOO ORVH LWV SHUIRUPDQFH DQG HI¿FLHQF\ in. ” max.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only.
(30”) 28 1/16”, (36”) 34” (42”) 39 3/4”, (48“) 45 3/4” 1 7/16” elec k/o 8” 6 7/ 1 15/16” 5 1/16” 9 15/16” 3 1/16” 2 3/4” (30”) 11 5/16”, (36”) 12 1/2” (42”) 12 1/2”, (48“) 12 1/2” 8 5/8” (30”) 14”, (36”) 17” (42”) 19 7/8”, (48“) 22 7/8” C/L 9 15/16” 3 1/16” elec k/o (30”) 11 5/16” (36”) 12 1/2” (42”) 12 1/2” (48“) 12 1/2” (30”) 29 3/4”, (36”) 35 3/4” (42”) 41 3/4”, (48“) 47 11/16” C/L FRONT BACK 13 9/16” 7 7/8” 6 7/8” 20 3/4” SIDE 10 2 1/2” TOP 1 3/8” Installation – $.
7/8 4 3/4” ” C/L (30”) 11 3/8” (36”) 14 3/8” (30”) 29 3/4”, (36”) 35 7/8” C/L FRONT BACK 14 3/4” 7” 6 7/8” 2 1/8” SIDE 11 2 1/4” 9 15/16” elec k/o 3 1/16” 1 7/8” TOP Installation – $.
(30”) 27 7/8”, (36”) 33 7/8”, (42”) 39 7/8” 9 15/16” elec k/o 2” 4 1/2” 3 1/16” 1 7/8” 1 7/16” 12” 8 5/8” 8” 5 7/ (30”) 14”, (36”) 17”, (42”) 20” C/L 12” (30”) 29 3/4”, (36”) 35 3/4”, (42”) 41 3/4” C/L FRONT BACK 15 3/8” 5 7/8” 6 3/8” 22 1/4” SIDE 12 2 1/16” 9 15/16” elec k/o 3 1/16” 1 3/8” TOP 5 1/2” Installation – $. 6SHFL¿FDWLRQV www.zephyronline.
3-1/4"x10" Rectangular Vertical Ducting 2. Replace round vertical transition adapter with rectangular transition adapter. Do not secure to hood body yet. 1. Using a Philips-head screwdriver remove the screws and round vertical transition adapter from top of hood body. 3ODFH [ UHFWDQJXODU FROODU RQ WRS RI UHFWDQJXODU transition adapter. Secure rectangular adapter and rectangular collar to hood body using the previously removed screws from step 1.
Installation – 3-1/4”x10” rectangular ducting preparation www.zephyronline.com %\ GHIDXOW WKH 7\SKRRQ DQG +XUULFDQH DUH SUH FRQ¿JXUHG IRU URXQG YHUWLFDO GXFWLQJ %\ GHIDXOW WKH &\FORQH LV SUH FRQ¿JXUHG IRU URXQG YHUWLFDO GXFWLQJ 3-1/4"x10" Rectangular Horizontal Ducting 1. Using a Philips-head screwdriver remove the screws and round vertical transition adapter from the top of the hood. 2.
WARNING $OO (OHFWULFDO ZRUN PXVW E\ SHUIRUPHG E\ TXDOL¿HG HOHFWULFLDQ RU SHUVRQ ZLWK VLPLODU WHFKQLFDO knowledge and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation – Mounting the Range Hood www.zephyronline.com Hood is designed for installation under a kitchen cabinet. See Fig. 1 for details. duct work 3UHSDUH GXFW ORFDWLRQ RQ KRRG YHUWLFDO RU KRUL]RQWDO 5HIHU WR 3DJHV IRU GXFWLQJ options. electrical 2. Measure and cut out duct and electrical openings in cabinet or wall to match up with the hood. Ducting and electrical dimensions can be found on Pages 10-12. Note: Make sure duct opening is large enough to apply aluminum duct tape.
5 Speed Indicators Q 4 Fan Speed Decrease 2 5 4 Lights On/Off 3 6 3 Fan Speed Increase 1 Power / Delay Off Button Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was last turned off at. (Example: Press button to turn off hood when on fan speed 3 and high lights. Press button again and the hood will turn back on at speed 3 and high lights.) Delay Off - With the fan on, press and hold the button for two seconds.
&RQWUROV $&7 9HUL¿FDWLRQ ± AK25 Electronic Touch www.zephyronline.com 2 Lights On/Off 1 Power / Delay Off / 1 2 3 3 Speed Indicators 1 Power / Delay Off Button / / Button will turn power on and off for entire hood (fan and lights.) - Hood will remember the last speed and light level it was last turned off at. (Example: Press / button to turn off hood when on fan speed 3 and high lights. Press / button again and the hood will turn back on at speed 3 and high lights.
3 2 1 2 Lights Off/Dim/Bright 0 2 1 0 1 BLOWER ON/OFF/SPEED SELECTION 0 is off, 1 is low speed, 2 is medium speed and 3 is high speed. 2 LIGHTS OFF/DIM/BRIGHT 0 is off, 1 is dim, and 2 is bright.
Maintenance – Self Cleaning www.zephyronline.com SELF CLEAING FEATURE Zephyr Typhoon, Hurricane and Cyclone hoods are filter-less with a self cleaning feature. The centrifugal blower system automatically liquifies cooking residue in its internal housing. All hoods are equipped with dishwasher safe residue cups to collect cooking residue during the self cleaning function. Cooking residues are often automatically liquified and can accumulate in the residue cups from everyday use.
Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel &OHDQ SHULRGLFDOO\ ZLWK ZDUP VRDS\ ZDWHU DQG FOHDQ FRWWRQ FORWK RU PLFUR ¿EHU FORWK $OZD\V UXE LQ WKH GLUHFWLRQ RI WKH stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR TYPHOON, HURRICANE & CYCLONE Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is 2. Check the power connection with the unit is not connecting properly. connected properly. 3. The switch board and control board wirings are disconnected. 3.
RED BLUE WHITE Model: AK2100/36/42/48B Voltage 120V 60Hz 3A Power consumption Total: 285W Lamp: Max.35Wx2 Fan: 215W RED Motor2 WHITE BLUE Motor1 BLUE WHITE GREEN WHITE BLACK BLUE AC120V THERMALLY PROTECTED 3RZHU FRQVXPSWLRQ VKRZQ DERYH IRU GHIDXOW &)0 EORZHU FRQ¿JXUDWLRQ ACT 390 CFM - Fan Max. 160W @ 2.4A, ACT 290 CFM - Fan Max. 140W @ 2.2A Model: AK2500/36B Voltage 120V 60HZ 2.4A Power consumption Total: 230W Lamp: Max.
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART # Replacement Parts /LJKW %XOE 05 *8 : HDFK Light Bulb Removal Suction Cup 5HVLGXH &XS $. 5HVLGXH &XS $. $. 6DIHW\ *ULOO 6WDLQOHVV $. 6DIHW\ *ULOO %ODFN $. 6DIHW\ *ULOO :KLWH $. 6DIHW\ *ULOO 6WDLQOHVV $. $. 6DIHW\ *ULOO %ODFN $. $. 6DIHW\ *ULOO :KLWH $. $.
Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Ten Year Limited Warranty for Parts: For ten years from the date of your original purchase of the Products, we will provide, fre
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | 26 Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Typhoon AK2100BS, B,W AK2136BS, B,W AK2142BS AK2148BS C TM Ai rfl ow Control Technology Hurricane AK2500BS, B, W AK2536BS, B,W C TM Ai rfl ow Control Technology Cyclone AK6500BS, B,W AK6536BS, B,W AK6542BS Numéro de modèle : Numéro de modèle : Date d’achat : Détaillant: JUL18.0401 © Zephyr Ventilation LLC.
INSTALLATION Feuille de calcul pour le conduit.................................7 Espace libre et hauteur de montage..........................8 Options d’installation pour le conduit.........................9 6SpFL¿FDWLRQV GH OD KRWWH..........................................10-12 Préparation du conduit rectangulaire 3-1/4” x 10”.....13-14 Préparation de l’électricité.........................................15 Montage de la hotte...................................................
Mise en garde de sécurité www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. CET APPAREIL N’EST PAS CONÇU POUR ÊTRE UTILISÉ À L’EXTÉRIEUR. ATTENTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV DWWLFV FUDZO VSDFHV RU garages. OPERATION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison.
Liste du matériel www.zephyronline.
pi 3-1/ 4” x 10” 1 pi rect., droit x( 6” circ., droit 1 pi x( ) = pi 7” circ., droit 1 pi x( ) = pi 3-1/ 4” x 10” 15 pi rect., coude à 90º x( ) = pi 3-1/ 4” x 10” 9 pi rect., coude à 45º x( ) = pi 3-1/ 4” x 10” 24 pi rect., coude plat à 90º x( 3-1/ 4” x 10” 30 pi x( ) = Longueur x Nombre utilisé Pièces de conduit Total Total 30 pi x( ) = pi 6” chapeau de toiture circ. 30 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 1 pi x( ) = pi 6” circ. à 16 pi rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com Si des changements de direction ou des adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. La hauteur de montage minimale ne devrait pas être moins de 24”. La hauteur de montage maximale ne devrait pas outrepasser 32”. in. ” max. 4 2 m ” 32 36” Il est important d’installer la hotte à la hauteur de montage adéquate.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal.
www.zephyronline.
Ø6 7/8 4 3/4” ” 22 1/8” 10 1/4” 1 5/8” (30”) 11 3/8” (36”) 14 3/8” 2 1/4” (30”) 27 7/8” (36”) 34” L/C L/C DEVANT ARRIÈRE 14 3/4” 7” 6 7/8” 2 1/8” CÔTÉ 11 Installation – (30”) 11 3/8” (36”) 14 3/8” (30”) 29 3/4”, (36”) 35 7/8” 2 1/4 ” 9 15/16” elec k/o 3 1/16” 1 7/8” DESSUS
www.zephyronline.
Conduit vertical rectangulaire de de 3-1/4”x10” 2. Avec un tournevis cruciforme, enlevez les vis et l’adaptateur circulaire vertical situés sur le dessus de la hotte. 1. Avec un tournevis cruciforme, enlevez les vis et l’adaptateur circulaire vertical situés sur le dessus de la hotte. 3. Placez le collier rectangulaire de 3-1/4”x10” sur l’adaptateur rectangulaire. Fixez l’adaptateur rectangulaire et le collier rectangulaire à la hotte en utilisant les vis que vous avez enlevées à l’étape 1.
Installation – Préparation du conduit rectangulaire de 3-1/4” x 10” www.zephyronline.com 3DU GpIDXW OHV PRGqOHV 7\SKRRQ HW +XUULFDQH VRQW FRQ¿JXUpV DYHF XQ FRQGXLW FLUFXODLUH YHUWLFDO GH ´ 3DU GpIDXW OH PRGqOH &\FORQH HVW FRQ¿JXUp DYHF XQ FRQGXLW FLUFXODLUH YHUWLFDO GH ´ Conduit vertical rectangulaire de de 3-1/4”x10” 1. Avec un tournevis cruciforme, enlevez les vis et l’adaptateur circulaire vertical situés sur le dessus de la hotte. 2.
AVERTISSEMENT 7RXV OHV WUDYDX[ pOHFWULTXHV GRLYHQW rWUH UpDOLVpV SDU XQ pOHFWULFLHQ TXDOL¿p RX SDU XQH SHUVRQQH possédant l’expérience technique et le savoir-faire nécessaire.
Installation – Montage de la hotte www.zephyronline.com La hotte est conçue pour être installée sous une armoire de cuisine. Consultez la ¿JXUH SRXU REWHQLU SOXV GH GpWDLOV Conduit 1. Préparez la hotte pour un conduit vertical ou horizontal. Rapportez-vous aux pages 11 et 12 SRXU FRQQDvWUH OHV GLIIpUHQWHV RSWLRQV GH FRQGXLW Électricité 2. Mesurez et pratiquez les ouvertures pour passer le conduit et l’électricité dans l’armoire ou le mur.
5 Indicateurs de vitesse 4 Lumières – Allumer/Éteindre Arrêt à retardement Q 4 2 5 Vitesse des ventilateurs – Augmenter 3 6 3 Vitesse des ventilateurs – Diminuer 1 Touche de mise en marche et arrêt à retardement - La touche vous permet d’allumer et d’éteindre la hotte (ventilateurs et lumières) - La hotte garde en mémoire la dernière vitesse et la dernière intensité d’éclairage utilisées.
&RPPDQGHV HW YpUL¿FDWLRQ GH OD 7&'$ ± 7RXFKH pOHFWURQLTXH $. www.zephyronline.com 1 Mise en marche – Arrêt à retardement / 1 2 2 Lumières – Allumer/Éteindre 3 3 Indicateurs de vitesse 1 Touche de mise en marche et arrêt à retardement / - La touche / vous permet d’allumer et d’éteindre la hotte (ventilateurs et lumières) - La hotte garde en mémoire la dernière vitesse et la dernière intensité d’éclairage utilisées.
3 2 1 0 2 Allumées/Veilleuse/Éteintes 2 1 0 1 VENTILATEUR : MARCHE/ARRÊT CHOIX DE VITESSE À 0, le ventilateur est éteint, à 1 il est à basse vitesse, à 2 il est à la vitesse moyenne et à 3 il est à la vitesse élevée. 2 LUMIÈRES : NORMAL/VEILLEUSE/ARRÊT À 0, les lumières sont éteintes, à 1 elles sont en mode veilleuse et à 2 elles sont à forte intensité.
Entretien – Autonettoyage www.zephyronline.
Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. N’utilisez pas de produits à blanchir au chlore ou d’agents nettoyants « orange ». Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
Dépannage www.zephyronline.com PROCÉDURES DE DÉPANNAGE POUR LES MODÈLES TYPHOON, HURRICANE ET CYCLONE Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1.
Transformateur Rouge Noir Moteur2 Blanc Blanc Jaune Blanc Bleu Modèle : AK2100/36/42/48B Tension 120V 60Hz 3A Consommation d’énergie Total : 285W Lampe : Max.
Listes des pièces et des accessoires www.zephyronline.com DESCRIPTION Nº DE PIÈCE Pièces de remplacement Ampoule halogène MR16 (GU10) 35W (unité) Z0B-0023 Pour commander des pièces, visitez-nous en ligne au http://store.zephyronline.
Garantie www.zephyronline.
www.zephyronline.com ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.