Use, Care, and Installation Guide www.zephyronline.com Tempest II AK7500ASX AK7536ASX AK7548ASX Model number: Serial Number: Date of Purchase: Sales Dealer: JAN08.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... Specifications ............................................................... Electrical ......................................................................... Mounting the Range Hood ...................................... Single and Dual Internal Blowers .........................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERATION Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing.
List of Materials www.zephyronline.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6” Round 30 Ft. wall cap with damper x( ) = Ft. 6” Round, straight 1 Ft. x( ) = Ft. 6” Round, roof cap x( ) = Ft. 7”-10” Round, 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect.90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect.45 0 elbow x( ) = Ft. 6” round to 16 Ft. 3-1/ 4” x 10” rect.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 26”. Maximum mount height should be no higher than 36”. 12" It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will lose its performance and efficiency.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside. Use metal ductwork only. Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
12” 2 1/16” *10 ” 4 5/16” 2” 6 7/16” 2 11/16” 18” ext elec blwr k/o k/o 4” 5 9/16” 2 5/16” 1 1/8” 8 9/16” 13 3/16” CL 29 15/16” (30”) 35 15/16” (36”) 47 15/16” (48”) 24” *10” transition used with dual and external blowers. 3/1 6” CL 24” (30”) 30” (36”) 42” (48”) back 8 10 ” 3/8 22 5/16” 14 4 1/4” 3 7/16” ø 9 15/16” 12 3/8” 9 15/16” side 2 3/4” 2 3/16” elec k/o 1 3/16” top 1 3/8” Installation – Specifications www.zephyronline.
WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation – Mounting the Range Hood www.zephyronline.com ! CAUTION: At least two installers are required due to the weight and size of the hood. C/L 1. Measure distance from range top to hood bottom (26” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (12 3/8” from line A) (This is the top of the board used to hang the hood) 4. Mark center line of wood board and align top of board with line B. Secure wood board to studs using (4) M4 wood screws.
Please turn to page 12 for instructions on installing CBI-600B in horizontal ducting mode. 2. Connect male end of blower wire to female plug in the hood. (plug is located inside the hood behind the control panel) 1. Position blower plate over bracket on inside back of hood and pivot up. Secure plate to hood with (2) 10x3/16” screws. (blower pictured is a PBI-1100A) 3. Single Blower – Connect 6” round duct work to blower collar.
Installation – CBI-600B Horizontal Ducting Conversion www.zephyronline.com HORIZONTAL DUCTING IS ONLY AVAILABLE IF USING THE CBI-600B SINGLE INTERNAL BLOWER. 1. Unscrew (4) screws holding blower to plate and remove blower. 2. Cover round blower opening on blower plate with 6” round metal cap included with the CBI-600B. Secure with (3) 3.5x8 screws. 3. Follow instructions on previous page and install blower plate into hood. 4.
7. Attach blower brackets to blower with (4) 10x3/16” screws. (2) screws for each bracket. 8. Place blower into round end of 6” round transition adapter. Attach brackets on blower to blower plate with (4) 3.5x8 screws. (2) screws for each bracket. 9. Attach rectangular starting collar to hood using the (6) screws removed from the rectangular cap in step 4. 13 Installation – CBI-600B Horizontal Ducting Conversion 6. Attach 6” round to rectangular transition adapter to hood with (4) M4x8 screws.
Installation – External Blower Preparation www.zephyronline.com 1. Place 10” round adapter on top of hood and secure with (4) M4x8 screws. Connect 10” round duct work to 10” round adapter. 2. Install threaded end of external blower wiring through external blower wiring knock out located inside the hood. 3. Place cap over threaded end of external blower wiring and secure by turning clockwise. 4.
3 5 Min Delay Off 5 Display (Speed level, Delay Off Indicator) 1 Blower On/Off 2 Adjust 3 Speed Levels 1 Blower On/Off By pressing , the blower is switched On and Off. When switched on, the blower turns on at the same speed it was switched off at. When switched off the entire hood powers off, including the lights. 2 Speed Selection The 3 speed levels are selected by pressing to decrease and to increase speed level. The display indicates speed level selected.
Maintenance – Cleaning and Filter Removal www.zephyronline.com SURFACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. Do not use products containing chlorine bleach or orange cleaners. For heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish and buff out the stainless luster and grain.
CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, stops and falls out. If bulbs are difficult to turn due to prolonged use, firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber/latex glove and turn counter clockwise.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR TEMPEST I AND TEMPEST II Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3.
PART # Replacement Parts Light Bulb MR16 (GU10) 35W (each) Baffle Filter (each) Z0B-0023 50210004 Optional Accessories Single Internal Blower Dual Internal Blower External Blower Heat Lamp Kit (30”) Heat Lamp Kit (36”) Heat Lamp Kit (48”) Back Splash (30”) Back Splash (36”) Back Splash (48”) 12” Duct Cover (30”) 12” Duct Cover (36”) 12” Duct Cover (48”) CBI-600B PBI-1100A CBE-1000 AK0700B AK0706B AK0708B AK0710 AK0716 AK0718 AK0720 AK0726 AK0728 To order parts, visit us online at http://store.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Ten Year Limited Warranty fo