www.zephyronline.com Installation Guide Tempest Recirculating Kit ZRC-0700 ZRC-0736 ZRC-0742 NOV18.0301 © Zephyr Ventilation LLC.
List of Materials www.zephyronline.
1 27 4 " or 9 2 16 " 1 33 4 " 3 or 39 16" 3 1 16 " 3 18 " 7 " 8 1 7 2 " 9 2 16 " 4" Front 15 29 16 " or 15 35 16 " Side 12" 3 or 15 41 16 " Installation – Specifications Top
Installation – Mounting the Diverter Box www.zephyronline.com Mounting the air diverter box FOR USE WITH AK7000BS, AK7500BS, AK7036BS, AK7536BS, AK7042BS and AK7542BS ONLY FOR USE WITH SINGLE INTERNAL BLOWER ONLY NOT COMPATIBLE WITH DUAL INTERNAL BLOWER 1. Position the air diverter box under cabinet. Mark the (4) keyholes for the #6 x 1” screws and electrical knock out opening with a pencil. Remove air diverter box and install the (4) #6 x 1” screws. Do not tighten screws all the way.
Mounting the Bracket and Baffle Filter 1. Insert the charcoal filter bracket into back side of baffle filter (side without handles). The (2) tabs on the bottom of the bracket should be inserted into the baffle filter first. Push the bracket towards the baffle filter to lock bracket in place. There is a clip on top of the bracket that will secure it to the baffle filter. (Fig. C) Repeat this step for each bracket. tab tab Fig. C Mounting the Bracket and Charcoal Filter 1.