User Manual

26
Titan Island Use, Care, and Installation Guide
TITAN ISLAND
WALL
PRO
ACT™ Conversion
Enabling ACT
To enable ACT™:
1. Before hood installation, gain access to PC board by following the steps shown on FIG. M.
2. Change plastic jumper positioning as shown in FIG. N to set the desired maximum blower CFM.
3. Re-install PC board and continue with hood installation.
4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the
hood body below the wiring diagram or in another clearly visible location.
To verify if your installer enabled ACT™:
1. With hood o, hold the On/O button for three seconds. The Display will show if ACT™ is disabled
and set to the maximum CFM or if ACT™ is enabled and set to one of the restricted maximum CFM
levels of 590, 390 or 290.
2. There should also be a foil label located inside the hood body near the wiring diagram that
indicates the blower CFM.
Models: AK76
- Locate PC board box on top of blower housing.
- Remove 4 screws attaching PC board cover.
FIG. M
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
1 3 5 7
2 4 6 8
Jump e r 7-8
DEFAULT POSITION
Max. Blower CFM
590
Jump e r 5-6
Max. Blower CFM
390
Jumper 3- 4
Max. Blower CFM
290
Jumper 1 -2
1 3 5 7
2 4 6 8
PC Board
Jumper Pins
Plastic
Jumper
FIG. N