WWW.ZEPHYRONLINE.COM Monsoon Mini AK9128BS, AK9134BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology JAN21.
CORE MONSOON MINI INSERT 2 Monsoon Mini Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................4-5 Operation ........................................................................................... 6 Electrical Requirements ........................................................
CORE Safety Information MONSOON MINI INSERT READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information MONSOON MINI INSERT READ AND SAVE THESE INSTRUCTIONS Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
CORE Installation Instructions MONSOON MINI INSERT Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting in..
CORE Installation Instructions MONSOON MINI INSERT Mounting Height, Clearance, & Ducting A minimum of 7” round or 3-1/4” x 10” rectangular duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use the ducting calculation sheet (on page 8) to compute total available duct run when using elbows, transitions and caps. ALWAYS, when possible, reduce the number or transitions and turns.
Installation Instructions ZEPHYRONLINE.COM Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
CORE Installation Instructions MONSOON MINI INSERT Ů 263 13” 4” 3-1/ 3” 28- 9-15 /1 3/8 ”, 3 4-3 / /16” , 32 -3/ 16” 6” 6-1/8” /16” 18-1 8” 3/4 View 4-3/4” 2-1/2” 1-1/2” (28”) 14-1/4” (34“) 17-1/4” 2” 8-3/4” Ø6 -3/ 3-1 4” /4” x 10” C/L Top View 4” 4-7/8” 3-1/4” C/L 8-3/4” 8-3/4” Back View 12 Monsoon Mini Use, Care, and Installation Guide
Installation Instructions ZEPHYRONLINE.COM Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
CORE Installation Instructions MONSOON MINI INSERT Mounting the Hood CAUTION At least two installers are required due to the weight and size of the hood. 1. Remove all packing materials and protective film prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel. 2. Cut out an opening in the bottom of the cabinet by following the dimensions in FIG. B.
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood 4. Lift liner into bottom opening of cabinet and secure to interior of cabinet using (12) #8 x 1/2” stainless steel screws; (4) screws in the front and (4) screws in the sides and (4) screws in the back. FIG. D. 5. Finalize installation of electrical and duct work. Seal duct work with certified aluminum duct tape. Power on liner, check for leaks around duct tape and verify proper operation.
CORE Installation Instructions MONSOON MINI INSERT Ducting Preparation If using hood in recirculating mode, skip these steps and turn to the next page. Vertical Ducting (7" Round) 1. Using a flat-head screwdriver, remove both the rectangular and round knock-out plates located on top of hood. 2. Secure 7" round collar to top of hood using (6) M4 x 6 screws. 1. Using a flat-head screwdriver, remove only the rectangular section of the knock-out plate located on top of hood. 2.
Installation Instructions ZEPHYRONLINE.COM Ductless Recirculation Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re-circulated back within the home.
CORE Features & Controls MONSOON MINI INSERT Slide Controls 1 Blower On/OŰ III II I 2 Űħ ħ II 0 I 0 1 BLOWER ON/OFF/SPEED SELECTION ř Űĕ ĕ Ę 2 LIGHTS OFF/DIM/BRIGHT ř Űĕ ĕ Ę 18 Monsoon Mini Use, Care, and Installation Guide
Maintenance ZEPHYRONLINE.COM Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
CORE Maintenance MONSOON MINI INSERT Ų 1. Push in on spring loaded filter handle. 2. Pull down on filter handle to remove filter. Ų Hood Model AK9128BS AK9134BS Part Number 50210041 50210041 Qty. to Order 2 2 To order parts, visit us online at http://store.zephyronline.com. LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts.
Wiring Diagram ZEPHYRONLINE.
CORE Troubleshooting MONSOON MINI INSERT Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. Possible Cause Solutions The power source is not turned ON. Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. The switch board or control board is defective. The wires on control board are loose.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The hood is not venting out properly. Filter is vibrating. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 26” and 36” range. Close all the windows and doors to eliminate the outside wind flow.
CORE List of Parts & Accessories MONSOON MINI INSERT Description Replacement Parts LumiLight LED, 6W Hybrid Baffle Filter (each) Part Number Z0B0049 50210041 Optional Accessories Recirculating Kit Replacement Charcoal Filter 7” Round Damper ZRC-9100A Z0F-C091 AK00067 To order parts, visit us online at http://store.zephyronline.com.
Limited Warranty ZEPHYRONLINE.
CORE Product Registration MONSOON MINI INSERT Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Monsoon Mini AK9128BS, AK9134BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology JAN21.
CORE MONSOON MINI INSÉRER 2 Monsoon Mini Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................4-5 Opération ........................................................................................... 6 Exigences électriques .......................................................
CORE Consignes de sécurité MONSOON MINI INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps. AVERTISSEMENT AVERTISSEMENT - POUR RÉDUIRE LES RISQUES D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES AUX PERSONNES, RESPECTEZ LES SUIVANTS: a) N’utilisez cet appareil que de la manière prévue par le fabricant.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité MONSOON MINI INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. Ź Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
CORE Instructions d’installation MONSOON MINI INSÉRER Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine n..
CORE Instructions d’installation MONSOON MINI INSÉRER Hauteur de montage, dégagement et gaine Un conduit d’au moins 7 po rond ou 3-1/4 po x 10 po rectangulaire doit être utilisé pour maintenir une efficacité maximale du flux d’air. Utilisez toujours uniquement des conduits métalliques de type rigide. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
Instructions d’installation ZEPHYRONLINE.COM Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
CORE Instructions d’installation MONSOON MINI INSÉRER ¯ Ů o 13 p 3p o 283/8 po, 34 263/ 16 p o 9-15 , 32-3/ 16 p /16 po o 4 po 3-1/ 6-1/8 po -3 / 8p /16 18-1 o po (28 po) 14-1/4 po (34 po) 17-1/4 po 8-3/4 po Ø6 -3/ 2 po 4-3/4 po 2-1/2 po 1-1/2 po Vue 3/4 4p 3-1 o /4 p ox 10 p o L/C 4 po 4-7/8 po L/C 8-3/4 po 3-1/4 po Vue de dessus 8-3/4 po Vue arrière 12 Monsoon Mini Guide d’utilisation, d’entretien et d’installation
Instructions d’installation ZEPHYRONLINE.COM Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
CORE Instructions d’installation MONSOON MINI INSÉRER Montage de la hotte ATTENTION Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. 1. Retirez tous les matériaux d’emballage et le film protecteur avant l’installation. Soyez prudent lors de l’installation pour éviter les rayures ou les dommages à l’acier inoxydable. (AK 912 28 -1/ 8) up 2p (A oo u 3 K91 34 4-1 ) /2 po 3.
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte 4. Soulevez la doublure dans l’ouverture inférieure de l’armoire et fixez-la à l’intérieur de l’armoire à l’aide de (12) vis en acier inoxydable n ° 8 x 1/2 po; (4) vis à l’avant et (4) vis sur les côtés et (4) vis à l’arrière. FIG. D. 5. Finaliser l’installation des travaux d’électricité et de conduits. Sceller les conduits avec du ruban adhésif en aluminium certifié.
CORE Instructions d’installation MONSOON MINI INSÉRER Préparation des conduits Si vous utilisez la hotte en mode de recirculation, ignorez ces étapes et passez à la page suivante. Conduit vertical (7 po Ronde) 1. À l'aide d'un tournevis à tête plate, retirez les plaques à défoncer rectangulaire et ronde situées sur le dessus du capot. 2. Fixez le collier rond de 7 po au haut de la hotte à l'aide de (6) vis M4 x 6. 1.
Instructions d’installation ZEPHYRONLINE.COM Recirculation sans conduit La recirculation sans conduit est destinée aux applications où un conduit d’évacuation ne peut pas être installé. Une fois convertie, la hotte fonctionne comme une hotte à recirculation plutôt que comme une hotte aspirante. Les fumées et les gaz d’échappement de la cuisson sont aspirés et filtrés par un ensemble de filtres à charbon en option. L’air est ensuite purifié et remis en circulation dans la maison.
CORE Fonctionnalités et commandes MONSOON MINI INSÉRER Commandes à glissière Veilleuse/Forte intensité Choix de Vitesse III II I II 0 I 0 1 Ventilateur Marche/Arrêt/Choix de Vitesse À 0 l’appareil est éteint; I équivaut à la vitesse lente, II à la vitesse moyenne et III à la vitesse maximale. 2 Lumières Éteindre/Forte intensité/Veilleuse À 0 la lampe est éteinte, I équivaut à la veilleuse et II à la forte intensité.
Entretien ZEPHYRONLINE.COM Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
CORE Entretien MONSOON MINI INSÉRER Ů £ 1. Appuyez sur la poignée du filtre à ressort. 2. Tirez sur la poignée du filtre pour retirer le filtre. Ů £ Modèle de capot AK9128BS AK9134BS Numéro d’article 50210041 50210041 Quantité à commander 2 2 Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com.
Schéma de câblage ZEPHYRONLINE.
CORE Dépannage MONSOON MINI INSÉRER Problème possible Après l'installation, l'appareil ne fonctionne pas. La lumière fonctionne, mais le ventilateur ne tourne pas. L'unité vibre. L'unité siffle. Le ventilateur fonctionne, mais les LED LumiLight ne le sont pas. 22 Cause possible Solutions La source d'alimentation n'est pas allumée. Assurez-vous que le disjoncteur et l’appareil sont sous tension. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement.
Dépannage ZEPHYRONLINE.COM Problème possible Les LED LumiLight clignotent lors du changement de niveau de vitesse. La hotte ne s'échappe pas correctement. Cause possible N/A Il s’agit d’une opération normale et la hotte fonctionne correctement. Utilisation de la mauvaise taille de conduit. Changer le conduit à la bonne taille. La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la plaque de cuisson et le bas de la hotte dans les limites de 26 po et 36 po.
CORE Liste des pièces et accessoires MONSOON MINI INSÉRER La description Pièces de rechange LumiLight LED, 6 W Filtre à chicane Numéro d’article Z0B0049 50210041 Accessoires optionnels Kit de recirculation Filtre à charbon de rechange Amortisseur rond de 7 po ZRC-9100A Z0F-C091 AK00067 Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com.
Garantie limitée ZEPHYRONLINE.
CORE Enregistrement du produit MONSOON MINI INSÉRER Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.