WWW.ZEPHYRONLINE.COM Monsoon Connect AK9428BS, AK9434BS, AK9440BS, AK9446BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology DEC20.
CORE MONSOON C O N N E CT INSERT 2 Monsoon Connect Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information ............................................................................ 4-6 Types of Safety Warnings ................................................................... 4 General Safety ..................................................................................4-5 Operation ........................................................................................... 6 Electrical Requirements ........................................................
CORE Safety Information MONSOON C O N N E CT INSERT READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information MONSOON C O N N E CT INSERT READ AND SAVE THESE INSTRUCTIONS Operation Ź Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. Ź The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
CORE Installation Instructions MONSOON C O N N E CT INSERT Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting n..
CORE Installation Instructions MONSOON C O N N E CT INSERT Mounting Height, Clearance, & Ducting A minimum of 8” round or 10” round duct for vertical ducting must be used to maintain maximum air flow efficiency. A 8” round duct may be used for horizontal ducting. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. Also use calculation (on page 11) to compute total available duct run when using elbows, transitions and caps.
Installation Instructions ZEPHYRONLINE.COM Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Ź Use single wall rigid metal ductwork only. Ź Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
CORE Installation Instructions MONSOON C O N N E CT INSERT Ů (30 (42 ”) 2 ”) 2-3 34 /8 -3/ ”, 8” (36 , (4 ”) 8” 28) 4 3/ 0- 8”, 1/4 ” 12” 3” rem an ote ten na 12” (30 (42 ”) 2 ”) 8-3 40 /8 -3/ ”, ( 8” 36” , (4 ) 8” 34) 4 3/ 6-1 8”, /4 ” 19 * 8” round ducting ** 10” round ducting 8” 3/ (30”) 11-3/16” (36”) 14-3/16” (42“) 17-3/16” (48”) 17-7/8” (30” only) 5-9/16” (36“, 42”, 48“) 6-1/8” 3/4 View 2” *8-1/16” **10-3/8” (30”) 9-1/4” (36”) 11-7/8” (42“) 14-7/8” (48”) 17-7/8” (30”) 9
Installation Instructions ZEPHYRONLINE.COM Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
CORE Installation Instructions MONSOON C O N N E CT INSERT Preparation & Installation CAUTION At least two installers are required due to the weight and size of the liner. 1. Remove all packing materials and protective film prior to installation. Use caution during installation to prevent scratches or damage to the stainless steel. Remove safety screw on top of hood body. 2. Cut out an opening in the bottom of the cabinet by following the dimensions in FIG. B.
Installation Instructions ZEPHYRONLINE.COM Preparation & Installation 1. Remove baffle filters by: 1) Pulling filter toward front of liner. 2) Pivoting rear of filter down. 1 2 1 1 2. Remove grease tray by: 1) Pulling up on tray to release from bottom panel. 2) Lifting tray out of liner body. 2 3. Remove left and right sidespacer panels by removing (2) screws from behind each panel, if applicable.
CORE Installation Instructions MONSOON C O N N E CT INSERT Preparation & Installation 1 Bottom Panel Screws 2 4. Remove bottom panel by: 1) Removing (2) screws from left and right sides of bottom panel. 2) Pulling bottom panel toward front of liner to release from locking tabs. Locking Tabs 5. Secure 8” or 10” round ducting collar to top of insert by (4) M4 x 6mm screws. 6. Vertical ducting preparation is complete. Refer to page 14, step 4 to complete installation.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Preparation 1. Follow steps 1 to 4 from pages 15 and 16. Remove blower molex plug. 2. Remove blower from liner by removing the (4) 3/16” x 3/8” screws from the top of the liner. Set screws aside for later usage. 3. Using a flat head screwdriver, remove 8” round knock-out plate at the back of the liner.
CORE Installation Instructions MONSOON C O N N E CT INSERT Horizontal Ducting Preparation 4. Place top rectangular cover plate over opening on top of the liner. NOTE: Make sure the cover plate tabs are on top of the cover plate as shown. From inside the liner, secure plate to top of liner with (2) 3/16 x 3/8 screws. At this point, install the liner into the cabinet by following the steps on page 14, step 4. After liner installation, continue on page 18. 5.
Installation Instructions ZEPHYRONLINE.COM Horizontal Ducting Preparation 2 1 1 7. Position blower inside liner body as shown by: 1) Rest the bottom horizontal ducting bracket on the two support clips located on the interior back wall of the liner. 2) Pivot top horizontal ducting bracket to meet captive nuts on interior back wall. 8. Secure blower to captive nuts on interior back wall of liner with (8) 3/16” x 3/8” screws, (4) screws for each bracket.
CORE Installation Instructions MONSOON C O N N E CT INSERT PBD-1300B Dual Blower Installation This range hood is equipped standard with a single blower vertical duct option. To convert from single blower vertical ducting to dual blower vertical ducting please following the instructions below. PBD-1300B dual blower kit compatible only with AK9434BS, AK9440BS, and AK9446BS. 1. Remove the baffle filters and if applicable, remove the side panels. Disconnect blower plug. 2.
Installation Instructions ZEPHYRONLINE.COM PBD-1300B Dual Blower Installation 5. Install previously removed blower onto one side of dual blower plate and attach by (4) previously removed screws from step 2. 6. Install blower from PBD-1300B kit onto other side of dual blower plate by (4) 3/16 x 3/8 screws. 7. Dual blower screw mount locations. 8. Remove (5) screws to remove the light panel. Install dual blower PCB inside the hood body.
CORE Installation Instructions MONSOON C O N N E CT INSERT PBD-1300B Dual Blower Installation 9. Refer to page 36-37 section for this step. Connect the wiring from the dual blower including both blower plugs, blower cable 6 pin connector (E), dual blower switch cable (H), black single pin power cord from dual blower (K), and white single pin power cord (F) to dual blower PCB. 10. Place 10” round adapter (included with PBD-1300B) on top of hood and secure with (4) M3.5 x 8 screws.
Features & Controls ZEPHYRONLINE.COM Proximity Controls Power Lights Display & Icons Adjust 6 Speed Levels PROXIMITY SENSOR Ź When approaching the hood while it is powered off, the Power, Fan Decrease, Fan Increase, and Light icons will illuminate, and “HELLO” will appear on the LCD display for 2 seconds. Ź If neither the fan nor lights are turned on within 60 seconds, the icons will turn off, and “GOODBYE” will appear on the LCD display for 2 seconds.
CORE Features & Controls MONSOON C O N N E CT INSERT Proximity Controls DISPLAY ICONS & FUNCTIONS Ů Ź The notification bell icon will illuminate when an action needs to be taken. Tapping the icon will cycle through the notifications. The notification bell will remain illuminated until all notifications are resolved. The notification bell will not illuminate when the hood and controls are powered off.
Features & Controls ZEPHYRONLINE.COM Proximity Controls Ļ Ů Ź Airflow Control Technology (ACT™) allows the installer to set the maximum fan CFM to align with local codes and regulations. When the fan is off, press and hold for 3 seconds to display ACT™ status. Ź ACT 290 = 3 speeds, ACT 390 = 4 speeds, ACT 590 = 5 speeds. Grease Filter Clean Reminder Ź After 60 hours of fan use, the notification bell icon will illuminate.
CORE Features & Controls MONSOON C O N N E CT INSERT Zephyr Connect Your range hood is compatible with our Zephyr Connect app. All you need is a WiFi connection with access to the Internet that can reach the location of your range hood. Zephyr Connect allows you to control your range hood from anywhere using a mobile device or your Amazon Alexa or Google Home smart speaker. Zephyr Connect also includes real time diagnostics and provides you with important product information.
Features & Controls ZEPHYRONLINE.
CORE Features & Controls MONSOON C O N N E CT INSERT Optional RF Remote Control To order the RF remote control, the part number is 14000005. The blue antenna wire needs to be extended for optimal signal. Please refer to section, Mounting the Hood, for instructions. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Features & Controls ZEPHYRONLINE.COM Optional RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. D. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote. Maximum remote control communication distance is 15 feet from the liner. FIG.
CORE Maintenance MONSOON C O N N E CT INSERT Hood & Filter Cleaning Surface Maintenance Ź Do not use corrosive detergents, abrasive detergents or oven cleaners. Ź Do not use any product containing chlorine bleach or any product containing chloride. Ź Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
Maintenance ZEPHYRONLINE.COM Ų ĕ Ę ė 1. Place filter into top groove of the liner as shown and pull towards front of liner using handles. 2. Pivot back of filter upwards so it is angled in the liner. 3. Push filter into channel on back of liner to lock into place. 1 2 FIG. F Removing the Grease Tray Grease tray has a hooked lip that attaches to bottom panel top edge. Remove grease tray by: 1. Pull up on tray to release from bottom panel. FIG. G1 2. Pull tray out of liner body.
CORE Maintenance MONSOON C O N N E CT INSERT LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. H): 1. Remove baffle filters. 2. Remove light panel by five screws. 3. Disconnect LED light quick connector. 4. Push in the two side clips on the ends of the LED light. 5. Push LED light through the light panel opening. Push the clip FIG.
ACT™ Conversion ZEPHYRONLINE.COM ů Ĭ Ļĭ Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of three most commonly specified CFM levels; 590, 390, or 290 CFM. The usage of ACT™ may not be necessary for your installation.
CORE ACT™ Conversion MONSOON C O N N E CT INSERT Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. I. 2. Change plastic jumper positioning as shown in FIG. J to set the desired maximum blower CFM. 3. Re-install PC board and continue with hood installation. 4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location.
ACT™ Conversion ZEPHYRONLINE.COM Enabling ACT™ 1. PC board located behind the light panel. 2. (If applicable) Remove both spacer panels by 2 screws for each spacer panel. 3. Remove 5 screws attaching light panel. FIG. I Jumper Pins 2 4 6 8 Plastic Jumper 1 3 5 7 Jumper 7-8 DEFAULT POSITION 2 4 6 8 2 4 6 8 2 4 6 8 2 4 6 8 1 3 5 7 PC Board 1 3 5 7 1 3 5 7 1 3 5 7 Jumper 5-6 Max. Blower CFM 590 Jumper 3-4 Max. Blower CFM 390 Jumper 1-2 Max. Blower CFM 290 FIG.
CORE Wiring Diagram MONSOON C O N N E CT White Black Green INSERT AK9428BS, AK9434BS, AK9440BS Wiring Diagram Body Black Black Red Motor Single Blower Body White Black Green White LED LED ANT WIFI MOTOR-2 WHITE WHITE WIFI MOTOR-1 K WHITE WHITE BLACK WHITE BLACK BLACK BLACK B/W WHITE BLACK BLACK B/W Dual Blower A. Wi-Fi connection wire C. Power wire for expansion PCB D. Power wire for expansion PCB E. Blower connection wire F. Blower connection wire G.
Wiring Diagram ZEPHYRONLINE.COM Green White Black AK9446BS Wiring Diagram Body Black Black Red Motor Single Blower Body White Black Green White LED WIFI LED LED LED ANT B/W K BLACK WHITE WHITE WHITE BLACK BLACK WHITE BLACK BLACK B/W Dual Blower MOTOR-1 BLACK MOTOR-2 WHITE WHITE WIFI A. Wi-Fi connection wire B. LED PCB wire C. Power wire for expansion PCB D. Power wire for expansion PCB E. Blower connection wire F. Blower connection wire G. Control connection wire H.
CORE Troubleshooting MONSOON C O N N E CT INSERT Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. Possible Cause Solutions The power source is not turned ON. Make sure the circuit breaker and the unit’s power is ON. The power line and the cable locking connector is not connecting properly. The switch board or control board wirings are disconnected. The switch board or control board is defective. The wires on control board are loose.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The hood is not venting out properly. The unit turns on by itself. Filter is vibrating. RF Remote control does not work. Possible Cause Using the wrong size of ducting. Change the ducting to the correct size. The hood might be hanging to high from the cook top. Adjust the distance between the cook top and the bottom of the hood within 24” and 34” range. Close all the windows and doors to eliminate the outside wind flow.
CORE Troubleshooting MONSOON C O N N E CT INSERT Possible Problem The range hood won’t connect to Wi-Fi. User cannot change Wi-Fi connections. Cannot bind the hood to my Zephyr Connect account. Zephyr Connect app won’t register user inputs. Zephyr Connect app stuck on “Loading”. 40 Possible Cause The user’s router or modem is turned off. The user’s router is connected to a 5 GHz wireless frequency. The user’s coaxial cables are loose. Solutions Turn on the router or modem. Connect to the 2.
List of Parts & Accessories ZEPHYRONLINE.COM Description Replacement Parts LumiLight LED, 6W Baffle Filter (each) Optional Accessories RF Remote Control Part Number Z0B0047 50210039 14000005 To order parts, visit us online at http://store.zephyronline.com.
CORE Notes MONSOON C O N N E CT INSERT 42 Monsoon Connect Use, Care, and Installation Guide
Limited Warranty ZEPHYRONLINE.
CORE Product Registration MONSOON C O N N E CT INSERT Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Monsoon Connect AK9428BS, AK9434BS, AK9440BS, AK9446BS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology DEC20.
CORE MONSOON C O N N E CT INSÉRER 2 Monsoon Connect Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité ....................................................................... 4-6 Types d’avertissements de sécurité ..................................................... 4 Sécurité générale...............................................................................4-5 Opération ........................................................................................... 6 Exigences électriques .......................................................
CORE Consignes de sécurité MONSOON C O N N E CT INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité MONSOON C O N N E CT INSÉRER LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération Ź Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. Ź Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine in..
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Hauteur de montage, dégagement et gaine Un conduit d’au moins 8 po rond ou 10 po rond pour les conduits verticaux doit être utilisé pour maintenir une efficacité maximale du débit d’air. Un conduit rond de 8 po peut être utilisé pour les conduits horizontaux. Utilisez toujours des conduits métalliques de type rigide uniquement. Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
Instructions d’installation ZEPHYRONLINE.COM Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. Ź Utilisez uniquement des conduits métalliques rigides à paroi simple.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER ¯ Ů 12 p (30 (42 po) po 22) 3 3/ 48 3/ po, 8p o, (36 p (48 o) po 28) 4 3/ 0- 8 p 1/4 o po , o 3p o an dis tenn tan e à ce 12 po * 8 po conduit rond ** 10 po conduit rond o 8p 3/ 19 (30 po) 9-1/4 po (36 po) 11-7/8 po (42 po) 14-7/8 po (48 po) 17-7/8 po 7-11/16 po 10-3/8 po entrée defoncable entrée defoncable Ø* 7 ** 9 -11/16 -15 p /16 o po L/C *9-1/2 po **14-3/16 po 5-1/2 po L/C Vue arrière 12 (30 po) 9-1
Instructions d’installation ZEPHYRONLINE.COM Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Préparation et installation AVERTISSEMENT Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la doublure. 1. Retirez tous les matériaux d’emballage et le film protecteur avant l’installation. Soyez prudent lors de l’installation pour éviter les rayures ou les dommages à l’acier inoxydable. Retirez la vis de sécurité sur le dessus du corps de la hotte. 2.
Instructions d’installation ZEPHYRONLINE.COM Préparation et installation 1. Retirez les filtres déflecteurs en: 1) Tirant le filtre vers l’avant de la doublure. 2) Pivotement de l’arrière du filtre vers le bas. 1 2 1 1 2. Retirez le plateau à graisse en: 1) Tirant sur le plateau pour le dégager du panneau inférieur. 2) Soulever le plateau hors du corps de la doublure. 2 3. Retirez les panneaux d’entretoise latéraux gauche et droit en retirant les (2) vis derrière chaque panneau.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Préparation et installation 1 Vis du panneau inférieur 2 4. Retirez le panneau inférieur en: 1) Retirez les (2) vis des côtés gauche et droit du panneau inférieur. 2) Tirer le panneau inférieur vers l’avant de la doublure pour le dégager des languettes de verrouillage. Verrouillage des onglets 5. Fixez le collier de conduit rond de 8 po ou 10 po au sommet de l’insert à l’aide de (4) vis M4 x 6 mm. 6.
Instructions d’installation ZEPHYRONLINE.COM Préparation des conduits horizontaux 1. Suivez les étapes 1 à 4 des pages 15 et 16. Retirez le bouchon molex du ventilateur. 2. Retirez le ventilateur de la gaine en retirant les (4) vis 3/16 ”x 3/8” du haut de la gaine. Mettez les vis de côté pour une utilisation ultérieure. 3. À l’aide d’un tournevis à tête plate, retirez le rond de 8 ”ou 3 1/4” x10 ”rect. plaques à défoncer à l’arrière de la doublure.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Préparation des conduits horizontaux 4. Placez la plaque de recouvrement rectangulaire supérieure sur l’ouverture au-dessus de la doublure. REMARQUE: assurezvous que les languettes de la plaque de recouvrement se trouvent sur le dessus de la plaque de recouvrement, comme illustré. De l’intérieur de la doublure, fixez la plaque au dessus de la doublure avec (2) vis 3/16 x 3/8.
Instructions d’installation ZEPHYRONLINE.COM Préparation des conduits horizontaux 2 1 1 7. Positionnez le ventilateur à l’intérieur du corps de la gaine comme indiqué par: 1) Posez le support de conduit horizontal inférieur sur les deux clips de support situés sur la paroi arrière intérieure de la gaine. 2) Faites pivoter le support de conduit horizontal supérieur pour qu’il rencontre les écrous captifs sur la paroi arrière intérieure. 8.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Installation de deux ventilateurs PBD-1300B Cette hotte de cuisinière est équipée de série d’une option de conduit vertical à un seul ventilateur. Pour passer d’un conduit vertical à une seule soufflante à un conduit vertical à double soufflante, veuillez suivre les instructions ci-dessous. Kit double soufflante PBD-1300B compatible uniquement avec AK9434BS, AK9440BS, ou AK9446BS. 1.
Instructions d’installation ZEPHYRONLINE.COM Installation de deux ventilateurs PBD-1300B 5. Installez le ventilateur précédemment retiré sur un côté de la plaque de ventilateur double et fixez-le à l’aide des (4) vis précédemment retirées de l’étape 2. 6. Installez le ventilateur du kit PBD-1300B sur l’autre côté de la plaque de ventilateur double à l’aide de (4) vis 3/16 x 3/8. 7. Emplacements de montage de deux vis de ventilateur. 8. Retirez les (5) vis pour retirer le panneau lumineux.
CORE Instructions d’installation MONSOON C O N N E CT INSÉRER Installation de deux ventilateurs PBD-1300B 9. Reportez-vous à la section page 36-37 pour cette étape. Connectez le câblage du double ventilateur, y compris les deux fiches du ventilateur, le connecteur à 6 broches du câble du ventilateur (E), le câble du commutateur du ventilateur double (H), le cordon d’alimentation noir à une broche du double ventilateur (K) et le cordon d’alimentation blanc à une broche (F) au PCB double ventilateur. 10.
Fonctionnalités et commandes ZEPHYRONLINE.COM Contrôles de proximité Allumer Lumières ű Ù Ajuster 6 niveaux de vitesse CAPTEUR DE PROXIMITÉ Ź Lorsque vous vous approchez de la hotte lorsqu’elle est hors tension, les icônes d’alimentation, de diminution du ventilateur, d’augmentation du ventilateur et d’éclairage s’allument et «BONJOUR» apparaît sur l’écran LCD pendant 2 secondes. Ź Les icônes restent allumées pendant que le capteur de proximité détecte quelqu’un près de la hotte.
CORE Fonctionnalités et commandes MONSOON C O N N E CT INSÉRER Contrôles de proximité Lumières Ź Appuyez sur l’icône des lumières pour changer le niveau d’éclairage de 1, 2, 3, désactivé. AFFICHER ICÔNES et FONCTIONS Ů Ź L’icône de la cloche de notification s’allumera lorsqu’une action doit être entreprise. Appuyez sur l’icône pour parcourir les notifications. La cloche de notification restera allumée jusqu’à ce que toutes les notifications soient résolues.
Fonctionnalités et commandes ZEPHYRONLINE.COM Contrôles de proximité ¯Ů Ļ Ź La technologie de contrôle du flux d’air (ACT™) permet à l’installateur de régler le CFM maximum du ventilateur pour s’aligner sur les codes et réglementations locaux. Lorsque le ventilateur est éteint, appuyez et maintenez pendant 3 secondes pour afficher l’état ACT™. Ź ACT 290 = 3 vitesses, ACT 390 = 4 vitesses, ACT 590 = 5 vitesses.
CORE Fonctionnalités et commandes MONSOON C O N N E CT INSÉRER Zephyr Connect Votre hotte de cuisine est compatible avec notre application Zephyr Connect. Tout ce dont vous avez besoin est une connexion WiFi avec accès à Internet qui peut atteindre l’emplacement de votre hotte. Zephyr Connect vous permet de contrôler votre hotte de cuisine de n’importe où à l’aide d’un appareil mobile ou de votre enceinte intelligente Amazon Alexa ou Google Home.
Fonctionnalités et commandes ZEPHYRONLINE.
CORE Fonctionnalités et commandes MONSOON C O N N E CT INSÉRER Télécommande RF en option Pour commander la télécommande RF, la référence est 14000005. Le fil d’antenne bleu doit être rallongé pour un signal optimal. Veuillez consulter la section, Montage de la hotte, pour les instructions. Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité peut annuler le droit de l’utilisateur à utiliser cet équipement.
Fonctionnalités et commandes ZEPHYRONLINE.COM Télécommande RF en option Caractéristiques de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. D. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile. Remarque: le support de télécommande ne charge pas la télécommande RF.
CORE Entretien MONSOON C O N N E CT INSÉRER Ů Entretien de surface Ź N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. Ź N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. Ź N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
Entretien ZEPHYRONLINE.COM Ů ¯ů ĕ Ę ė 1. Placez le filtre dans la rainure supérieure de la doublure comme illustré et tirez vers l’avant de la doublure à l’aide des poignées. 2. Faites pivoter l’arrière du filtre vers le haut pour qu’il soit incliné dans la doublure. 3. Poussez le filtre dans le canal à l’arrière de la doublure pour le verrouiller en place. 1 2 FIG.
CORE Entretien MONSOON C O N N E CT INSÉRER LumiLight LED Dans le cas peu probable où votre LumiLight LED tombe en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées. Retrait de la LED LumiLight (FIG. H): 1. Retirer les filtres déflecteurs. 2. Retirez le panneau lumineux par cinq vis. 3. Débranchez le connecteur rapide de la lumière LED. 4.
Conversion ACT™ ZEPHYRONLINE.COM Technologie de contrôle du débit d’air (ACT™) Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuisinière peut déplacer. ACT™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de kits d’air d’appoint coûteux. ACT™ permet à l’installateur de régler facilement la vitesse maximale du ventilateur à l’un des trois niveaux CFM les plus couramment spécifiés; 590, 390 ou 290 CFM.
CORE Conversion ACT™ MONSOON C O N N E CT INSÉRER Activer ACT™ Pour activer ACT™: 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes illustrées à la FIG. I. 2. Changez le positionnement du cavalier en plastique comme illustré à la FIG. J pour régler le CFM maximum souhaité du ventilateur. 3. Réinstallez la carte de circuit imprimé et poursuivez l’installation de la hotte. 4.
Conversion ACT™ ZEPHYRONLINE.COM Activer ACT™ 1. Carte électronique située derrière le panneau lumineux. 2. (Le cas échéant) Retirez les deux panneaux d'espacement par 2 vis pour chaque panneau d'espacement. 3. Retirez les 5 vis fixant le panneau lumineux. FIG.
CORE Schéma de câblage MONSOON C O N N E CT AK9428BS, AK9434BS, AK9440BS Schéma Blanc Noir Vert INSÉRER Corps Noir Rouge Noir Souffleur simple Moteur Corps ANT Blanc Noir Vert Blanc LED LED WIFI BLANC BLANC NOIR A. Fil de connexion Wi-Fi C.Câble d’alimentation pour PCB d’extension D.Câble d’alimentation pour PCB d’extension E. Fil de connexion du ventilateur F. Fil de connexion du ventilateur G. Fil de connexion de contrôle H. Circuit imprimé à double ventilateur pour passer le fil I.
Schéma de câblage AK9446BS Schéma Blanc Noir Vert ZEPHYRONLINE.COM Corps Noir Rouge Noir Souffleur simple Moteur Corps ANT Blanc Noir Vert Blanc LED WIFI LED LED LED BLANC BLANC NOIR BLANC NOIR NOIR BLANC NOIR NOIR NOIR Double ventilateur K BLANC/NOIR MOTEUR-1 BLANC/NOIR MOTEUR-2 BLANC BLANC WIFI A. Fil de connexion Wi-Fi B. Fil de carte PCB de LED C.Câble d’alimentation pour PCB d’extension D.Câble d’alimentation pour PCB d’extension E. Fil de connexion du ventilateur F.
CORE Dépannage MONSOON C O N N E CT INSÉRER Problème possible Après l'installation, l'appareil ne fonctionne pas. La lumière fonctionne, mais le ventilateur ne tourne pas. L'unité vibre. L'unité siffle. Le ventilateur fonctionne, mais les LED LumiLight ne le sont pas. 38 Cause possible Solutions La source d'alimentation n'est pas allumée. Assurez-vous que le disjoncteur et l’appareil sont sous tension.
Dépannage ZEPHYRONLINE.COM Problème possible La hotte ne s'échappe pas correctement. Cause possible Utilisation de la mauvaise taille de conduit. Changer le conduit à la bonne taille. La hotte est peut-être suspendue trop haut de la table de cuisson. Ajustez la distance entre la plaque de cuisson et le bas de la hotte dans les limites de 24 po et 34 po. Fermez toutes les fenêtres et portes pour éliminer le vent extérieur.
CORE Dépannage MONSOON C O N N E CT INSÉRER Problème possible Cause possible La hotte ne se connecte Le routeur ou le modem de pas au Wi-Fi. l’utilisateur est désactivé. Le routeur de l’utilisateur est connecté à une fréquence sans fil de 5 GHz. Les câbles coaxiaux de l’utilisateur sont desserrés. Le Wi-Fi sur le téléphone de l'utilisateur est désactivé. L'utilisateur se connecte au mauvais réseau Wi-Fi. La hotte n'est pas à portée de la connexion Wi-Fi. Des obstacles bloquent la force du signal Wi-Fi.
Liste des pièces et accessoires ZEPHYRONLINE.COM La description Pièces de rechange LumiLight LED, 6 W Filtre à chicane (chacun) Numéro d’article Z0B0047 50210039 Accessoires optionnels Télécommande RF 14000005 Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com.
CORE Remarques MONSOON C O N N E CT INSÉRER 42 Monsoon Connect Guide d’utilisation, d’entretien et d’installation
Garantie limitée ZEPHYRONLINE.
CORE Enregistrement du produit MONSOON C O N N E CT INSÉRER Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.