Installation Instructions
Ducting Options
Use single wall rigid metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct
Tape.
Fire Hazard: NEVER exhaust air or terminate ductwork into
spaces between walls, crawl spaces, ceilings, attics, or garages.
All exhaust must be ducted to the outside, unless using the
recirculating option.
WARNING
Roof Cap
6” or 10”
round duct*
30” to 72”
above cooking
surface
* 6”: CBI-290C, CBI-600A
* 10”: CBI-290C, CBI-600A, PBI-1100B
CBE-1000A, PBN-1000A
external blower
Air Return
Vent**
Optional Recirculating Kit
Attic or crawl space
Blower
housing
30” to 72”
above cooking
surface
30” to 72”
above cooking
surface
30” to 72”
above cooking
surface
In-line
blower
Roof Pitch w/
Flashing & Cap
10” round
duct
Blower
housing
10” round
duct
6” round
duct
Blower options are from top, side or front
of blower housing
** Air return vent must be a minimum of 6 feet from hood. Recirculating kit, ZRC-01LX, is only
compatible with single internal blower models, CBI-290C and CBI-600A.