Use and Care Manual
10
1.  Measure from range top to hood bottom and mark line A.  
(24” minimum from range top) .
2.  Plum and mark center line.
3.  Mark mounting height line B. (15-7/8” from line A)
4.  Mark mounting spread from C/L. (8-15/16”) 
5.  Fasten (2) 6 x 1-1/2” screws into studs on line B but 
do not tighten all the way. Note: wood blocking may 
need to be added behind the drywall if no studs are 
present. Wall anchors may also be used, check local 
codes for compliance. Failure to use suitable wall 
anchors and screws to hold the weight of the hood 
could result in personal injury or damage to cooking 
surface or counter.
6.  Remove (2) screws securing junction box to the top of 
the blower housing. Remove junction box (FIG. B #1).
7.  Remove the mesh lter. Hang hood onto the mounting 
screws and hand tighten each screw. (FIG. A #1) Secure 
third 6 x 1-1/2” screw with washer through inside of hood 
into wall for extra support. (FIG. A #2) 
8.  Center and attach duct cover mounting bracket to wall 
just below the ceiling or sot using (2) 6 x 1” screws. 
(FIG. A #3)
9. Install duct work and seal with aluminum duct tape*. 
Re-install junction box with cable lock and install the 
electrical. (FIG. B #2)
10. Power up hood to verify all functions and check for leaks 
around duct tape.
11. Place telescopic duct covers onto hood and extend 
inner (top) duct cover upwards and secure to duct cover 
bracket using (2) M3.5 x 8 screws. 
12. Reinstall aluminum mesh lter.
 * If using hood in recirculating mode you must secure the 
air diverter plate onto wall before installing duct work and 
duct covers. Turn to page 12 for more details.
15 
7/8
”
Brackets are 
pre-installed
8 
15/16
”
24” Min.
1
2
A
B
3
Duct Cover Bracket
CAUTION: At least two installers are
required due to the weight and size of the
hood.
!
WARNING:  Electrical  wiring  must  be  done  by  a  qualified  person(s)  in
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
!
Cable Lock
A cable locking connector (not supplied) might 
be required by local codes. Check with local 
requirements and codes, purchase and install 
appropriate connector if necessary.
Installation – Mounting the Hood, BMI
Cable Lock
2
1
FIG. B
FIG. A