WWW.ZEPHYRONLINE.COM Okeanito COK-E36CSX, COK-E42CSX, COK-E48CSX, COK-E36CBGX, COK-E42CBGX, COK-E48CBGX EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DEC21.
DESIGNER O K E A N I TO WA L L 2 Okeanito Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information............................................................................. 4-6 Types of Safety Warnings.................................................................... 4 General Safety...................................................................................4-5 Operation............................................................................................ 6 Electrical Requirements.........................................................
DESIGNER Safety Information O K E A N I TO WA L L READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
DESIGNER Safety Information O K E A N I TO WA L L READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. ► The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
DESIGNER Installation Instructions O K E A N I TO WA L L Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round duct work must be used to maintain maximum air flow efficiency with the 290/600 CFM internal blower. A minimum of 8” to 10” round duct work must be used with the 1000 CFM remote blower. A n. mi x. B ma C n. mi x. D ma in. ” max. 4 2 ”m 36 Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%.
DESIGNER Installation Instructions O K E A N I TO WA L L Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. ► Use single wall rigid metal ductwork only. ► Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM Hood Specifications (36”) 5” (42“) 8” (48“) 3-1/2” 19-3/4” 10” Bottom View (36”) 26-1/16” (42“) 26-1/16” (48“) 41” 14-1/2” 19-3/4” Front View 21” 36”, 42”, 48” duct cover 6” C/L Standard Duct Cover min. : 30-1/2” max. : 49-1/2” 13-1/2” 10” 5-1/8” 8” collar C/L Side View 4-1/4” 6” collar C/L Top View 22-3/4” Okeanito Use, Care, and Installation Guide Z1C-00OK Extension min. : 44” max.
DESIGNER Installation Instructions O K E A N I TO WA L L Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Installation Instructions ZEPHYRONLINE.COM Internal Blower Preparation 1. Position internal blower inside hood body so internal blower collar protrudes through 6” round flange opening. 2. Secure internal blower to internal blower flange by (4) M4*16 screws from internal blower hardware. 3. Position capacitor box inside hood body and secure by (2) M4*8 screws from internal blower hardware. 4. Secure ground wire from capacitor box to ground wire rivet nut next to capacitor box. 5.
DESIGNER Installation Instructions O K E A N I TO WA L L Remote Blower Preparation 1. Remove internal blower flange from motor housing by (6) screws. 2. Install remote blower 8” round collar. Attach by (4) M4*8 screws. 3. Install threaded cable lock and remote blower wiring harness through the remote blower wiring knockout. Attach by (4) M4*8 screws.
Installation Instructions ZEPHYRONLINE.COM Mounting the Range Hood Top 8-1 C 6” 1/1 6” gap between bracket and wall C/L L C/ B 14-1/2” 9-11/16” A min. 26” max. 36” C/L Bottom FIG. B FIG. C FIG. D 1. Measure from cooking surface to desired hood bottom, level and mark line A. (26” minimum from cooking surface) 2. Plum and mark center line. . n i Follow center line up to the ceiling, measure and mark ceiling bracket . line C, 6” out from maxmount ” the wall onto the ceiling. FIG. C.
DESIGNER Installation Instructions O K E A N I TO WA L L Mounting the Range Hood Back View 10-9/16” 9-15/16” Upper duct cover attachment screw locations 1-7/8” 7/8” remote blower knockout C/L FIG. E electrical knockout FIG. F Set screw Front Back FIG. G 10. Attach wall bracket to wall by (3) M4*38 screws with washers. NOTE: Wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check with local codes for compliance.
Features & Controls ZEPHYRONLINE.COM Touch Controls 1 Blower On/Off 5 Display (speed level, delay off, filter clean) 2 Adjust 3 Speed Levels 6 Mood Light On/Off 4 Lights Low/Medium/High/Off 3 5 Min Delay Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 1. 2. Speed Selection to decrease fan speed. 3, 2, 1. - Press - If fan is on Speed 1 and is pressed, the fan will power off. - Press to increase fan speed. Fan On, 1, 2, 3.
DESIGNER Features & Controls O K E A N I TO WA L L Touch Controls Baffle Filter Clean Reminder A set of baffle filters are fitted by the factory, these baffle filters are intended to filter out residue from cooking. The filters need not be replaced on a regular basis but are required to be kept clean. The Baffle Filter Clean reminder function in the microprocessor will automatically indicate by a flashing F when the baffle filters need to be cleaned after every 60 hours of use.
Maintenance ZEPHYRONLINE.COM Hood & Grease Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
DESIGNER Maintenance O K E A N I TO WA L L Removing the Grease Filter (FIG. H) 1. Pull filter towards front of the range hood using handles. 2. Pivot the back of the filter downward. 1 3. Push filter to the rear and remove. 2 3 FIG. H Swivel LumiLight LED In the unlikely event that your swivel LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. I) 1. Remove grease filters. 2.
Wiring Diagram ZEPHYRONLINE.COM VOLTS COK-E36/42/48CSX COK-E36/42/48CBGX 120 HZ MAX AMPS 60 CBI-290C 0.8 CBI-390A 2.1 CBI-600A 2.
DESIGNER Wiring Diagram O K E A N I TO WA L L COK-E36/42/48CSX COK-E36/42/48CBGX VOLTS HZ MAX AMPS 120 60 CBE-1000 6.2 PBN-1000A 5.
Troubleshooting ZEPHYRONLINE.COM Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. The unit is vibrating. Possible Cause Solutions The power source is not turned ON. The power line and the cable locking connector is not connecting properly. The switch board and control board wirings are disconnected. Make sure the circuit breaker and the unit’s power is ON. Check the power connection with the unit is connected properly.
DESIGNER Troubleshooting O K E A N I TO WA L L Possible Problem The hood is not venting out properly. Possible Cause Solutions Using the wrong size of ducting. The hood might be hanging to high from the cook top. Filter is vibrating. 24 The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood. Blockage in the duct opening or ductwork. There are too many turns within the ducting. Filter is loose.
List of Parts & Accessories ZEPHYRONLINE.COM Description Replacement Parts Baffle Filter (each) LED Bulb, 4W Swivel LumiLight LED, 6W Optional Accessories Duct Cover Extension Single Internal Blower External Blower In-line Blower Part Number 50210036 P12010008 Z0B0052 Z1C-00OK CBI-290C / CBI-600A CBE-1000 PBN-1000A To order parts, visit us online at http://store.zephyronline.com.
DESIGNER Notes O K E A N I TO WA L L 26 Okeanito Use, Care, and Installation Guide
Limited Warranty ZEPHYRONLINE.COM Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.
DESIGNER Product Registration O K E A N I TO WA L L Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Okeanito COK-E36CSX, COK-E42CSX, COK-E48CSX, COK-E36CBGX, COK-E42CBGX, COK-E48CBGX EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation DEC21.
DESIGNER O K E A N I TO MUR 2 Okeanito Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité........................................................................ 4-6 Types d’avertissements de sécurité...................................................... 4 Sécurité générale................................................................................4-5 Opération............................................................................................ 6 Exigences électriques.......................................................
DESIGNER Consignes de sécurité O K E A N I TO MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps.
Consignes de sécurité ZEPHYRONLINE.
DESIGNER Consignes de sécurité O K E A N I TO MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. ► Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
DESIGNER Instructions d’installation O K E A N I TO MUR Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine A n. mi x. B ma C n. mi x. D ma n. mai x. om p 24 po 36 Un minimum de conduits ronds de 6” doit être utilisé pour maintenir une efficacité maximale du débit d’air avec le ventilateur interne de 290/600 CFM. Un minimum de conduits ronds de 8” à 10” doit être utilisé avec le ventilateur à distance de 1000 CFM.Les conduits flexibles peuvent restreindre le débit d’air jusqu’à 50%.
DESIGNER Instructions d’installation O K E A N I TO MUR Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. ► Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM Spécifications de la hotte (36 po) 5 po (42 po) 8 po (48 po) 3-1/2 po (36 po) 26-1/16 po (42 po) 26-1/16 po (48 po) 41 po 21 po 14-1/2 po 10 po Vu de dessous 19-3/4 po 19-3/4 po Vue de face 36 po, 42 po, 48 po Recouvrement de conduit standard min. : 30-1/2 po max. : 49-1/2 po 13-1/2 po 10 po 5-1/8 po L/C du collier de 8 po L/C du recouvrement Vue de côté 4-1/4 po L/C du collier de 6 po 6 po Vue de dessus Pièce de prolongement Z1C-00OK min.
DESIGNER Instructions d’installation O K E A N I TO MUR Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette l’insert doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
Instructions d’installation ZEPHYRONLINE.COM Préparation du ventilateur interne 1. Positionnez le ventilateur interne à l’intérieur du corps de la hotte de manière à ce que le collier du ventilateur interne dépasse de l’ouverture à bride ronde de 6 po. 2. Fixez le ventilateur interne à la bride du ventilateur interne à l’aide de (4) vis M4*16 du matériel du ventilateur interne. 3.
DESIGNER Instructions d’installation O K E A N I TO MUR Préparation du ventilateur à distance 1. Retirez la bride interne du ventilateur du boîtier du moteur à l’aide de (6) vis. 2. Installez le collier rond de 8 po du ventilateur à distance. Fixez par (4) vis M4 * 8. 3. Installez le verrou de câble fileté et le faisceau de câblage du ventilateur à distance à travers l’orifice défonçable du câblage du ventilateur à distance. Fixez par (4) vis M4 * 8.
Instructions d’installation ZEPHYRONLINE.COM Montage de la hotte de cuisinière C 6 po 8-1 1/1 6p o C/L Sommet espace entre le support et le mur L C/ B 9-11/16 po 14-1/2 po A min. 26 po max. 36 po C/L Bas FIG. B FIG. C FIG. D 1. Mesurez de la surface de cuisson au fond de la hotte désiré, nivelez et marquez la ligne A. (26 po minimum de la surface de cuisson) 2. Prune et marquer la ligne médiane. n..
DESIGNER Instructions d’installation O K E A N I TO MUR Montage de la hotte de cuisinière 10-9/16 po Vue arrière 9-15/16 po Emplacements des vis de fixation du couvercle de conduit supérieur 1-7/8 po 7/8 po Entrée défonçable Entrée défonçable du ventilateur à L/C pour l’électricité distance FIG. E FIG. F vis de réglage Devant Arrière FIG. G 10. Fixez le support mural au mur à l’aide de (3) vis M4*38 avec rondelles.
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles 1 Ventilateur Marche/Arrêt 5 Afficheur (Vitesse, arrêt à retardement, nettoyage des filtres) 2 Choix de 3 vitesses 6 Lumière d'ambiance activée/désactivée 4 Lumière: Bas/Moyen/Élevé/Désactivé 3 Arrêt à retardement (5 min.) 1. Ventilateur : Marche/Arrêt Appuyez sur pour allumer ou éteindre le ventilateur. Lorsque vous l’allumez, le ventilateur se met en marche à la vitesse 1. 2.
DESIGNER Fonctionnalités et commandes O K E A N I TO MUR Commandes tactiles Indicateur de nettoyage des filtres déflecteurs Un ensemble de filtres déflecteurs est installé par le fabricant. Ces filtres déflecteurs ont pour fonction de filtrer les résidus de cuisson. Ils ne nécessitent aucun remplacement sur une base régulière, mais ils doivent être gardés propres.
Entretien ZEPHYRONLINE.COM Nettoyage de la hotte et du filtre à graisse Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. ► N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
DESIGNER Entretien O K E A N I TO MUR Retrait du filtre à graisse (FIG. H) 1. Tirez le filtre vers l’avant de la hotte à l’aide des poignées. 2. Faites pivoter l’arrière du filtre vers le bas. 1 3. Poussez le filtre vers l’arrière et retirez-le. 2 3 LumiLight LED pivotante FIG. H Dans le cas peu probable où votre LumiLight LED pivotante tomberait en panne, veuillez contacter Zephyr pour commander des pièces de rechange.
Schéma de câblage ZEPHYRONLINE.COM VOLTS COK-E36/42/48CSX COK-E36/42/48CBGX 120 HZ Ampérage maximal 60 CBI-290C 0.8 CBI-390A 2.1 CBI-600A 2.
DESIGNER Schéma de câblage O K E A N I TO MUR COK-E36/42/48CSX COK-E36/42/48CBGX VOLTS HZ Ampérage maximal 120 60 CBE-1000 6.2 PBN-1000A 5.
Dépannage ZEPHYRONLINE.COM Problème possible Après l’installation, l’appareil ne fonctionne pas. Cause possible Solutions La source d’alimentation n’est pas allumée. La ligne électrique et le connecteur de verrouillage du câble ne se connectent pas correctement. Les câblages du tableau de commande et du tableau de commande sont déconnectés. Assurez-vous que le disjoncteur et l’alimentation de l’unité sont allumés. Vérifiez que la connexion d’alimentation avec l’unité est correctement connectée.
DESIGNER Dépannage O K E A N I TO MUR Problème possible Cause possible Le ventilateur fonctionne, mais pas les lumières. Le connecteur de la lumière LED est déconnecté. Lumière LED défectueuse. La hotte ne s’évacue pas correctement. Utiliser la mauvaise taille de conduit. Le filtre vibre. 24 Solutions Connectez le connecteur de la lumière LED. Changer la lumière LED. Changez le conduit à au moins 6 po ou plus pour le ventilateur interne et 8 po ou plus pour le ventilateur externe.
Liste des pièces et accessoires ZEPHYRONLINE.COM La description Pièces de rechange Filtre à chicane (chacun) Ampoule LED, 4W LumiLight LED, 6W Accessoires optionnels Rallonge de couvercle de conduit Ventilateur interne simple Ventilateur externe Ventilateur en ligne Numéro d’article 50210036 P12010008 Z0B0052 Z1C-00TP CBI-290C / CBI-600A CBE-1000 PBN-1000A Pour commander des pièces, visitez-nous en ligne à http://store.zephyronline.com.
DESIGNER Remarques O K E A N I TO MUR 26 Okeanito Guide d’utilisation, d’entretien et d’installation
Garantie limitée ZEPHYRONLINE.COM Garantie limitée POUR OBTENIR UN SERVICE SOUS GARANTIE OU POUR TOUTE QUESTIONS LIÉES AU SERVICE Les clients des États-Unis doivent appeler le: 1-888-880-8368 ou nous contacter à: zephyronline.com/contact Clients du Canada, veuillez appeler: 1-800-361-0799 ou par courriel: service@distinctive-online.
DESIGNER Enregistrement du produit O K E A N I TO MUR Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.