Use and Care Manual
Table Of Contents
13
Trapeze Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Internal Blower Preparation
2.  Secure internal blower to internal 
blower flange by (4) M4*16 screws 
from internal blower hardware.
1.  Remove internal blower flange 
from motor housing by (6) screws.
3.  Secure AC power wiring box to 
internal blower flange by (2) M4*8 
screws.
5.  Connect 9 pin molex connector 
from capacitor cable to 9 pin 
molex connector from internal 
blower.
4.  Secure ground wire to underside 
of internal blower flange by (1) 
3/16*3/8 screw and (1) washer.
6.  Re-install internal blower flange 
to motor housing by (6) screws 
previously removed from step 1.
8.  Connect 6 pin molex connector 
from capacitor cable to 6 pin 
molex connector from control 
box. Connect 2 pin plug from AC 
power cable to 2 pin plug from 
control box. Secure cables to 
hood interior with zip ties and zip 
tie holders.
7.  Secure motor housing to hood 
body by (12) M4*6 screws.
9.  Secure capacitor box to internal 
hood body by (2) M4*8 screws 
and secure ground wire by (1) 
3/16*3/8 screws.