Trapeze Use, Care, and Installation Guide
ZEPHYRONLINE.COM
Installation Instructions
Mounting Height, Clearance, & Ducting
A minimum of 6” round duct work must be used to maintain 
maximum air flow eciency with the 290/600 CFM internal 
blower. A minimum of 8” to 10” round duct work must be used 
with the 1000 CFM remote blower.
Always use rigid type metal ducts only. Flexible ducts could 
restrict air flow by up to 50%.
Also use calculation (on page 8) to compute total available duct 
run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or transitions and 
turns. If long duct run is required, increase duct size. 
If turns or transitions are required; install as far away from insert 
duct output and as far apart, between the two as possible.
Minimum mount height between range top to insert bottom 
should be no less than 24”.
Maximum mount height should be no higher than 36”.
It is important to install the insert at the proper mounting height. 
Inserts mounted too low could result in heat damage and fire 
hazard; while inserts mounted too high will be hard to reach and 
will lose its performance and eciency.
min. A
max. B
        Standard   Extension
Hood Heights      Duct Cover   Duct Cover
 minimum (A)   34”    47“
 maximum (B)   51-
1/2” 72”
Ceiling Heights
 minimum (C)  94” (7’ 10”) 107“ (8‘ 11”)
 maximum (D) 123-
1/2” (10’ 3-1/2“) 144” (12’)
36”
24” min.
36” max.
min. C
max. D
If available, also refer range manufacturer’s height clearance requirements and recommended insert 
mounting height above range.
For shipment and installation damages:
 ► Please fully inspect unit for damage before installation.
 ► If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or 
replacement.
 ► If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
 ► If the unit is damaged by the installer (if other than the customer), repair of replacement must be 
made by arrangement between customer and installer.