WWW.ZEPHYRONLINE.COM Savona ZSA-E30FB, ZSA-E30FW, ZSA-E30FS, ZSA-E30FBS, ZSA-M90FB, ZSA-M90FW, ZSA-M90FS, ZSA-M90FBS Anzio ZAN-E24DS, ZAN-E30DS, ZAN-E30DBS, ZAN-M90DS ZAN-M90DBS Ravenna ZRV-E30CGC, ZRV-E30CGG, ZRV-E30CBSGG, ZRV-M90CGC, ZRV-M90CGG, ZRV-M90CBSGG Roma ZRO-E30FS, ZRO-M90FS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology MAR22.
CORE Z S A , Z A N , Z R V, Z R O WA L L 2 Savona, Anzio, Ravenna, Roma Use, Care, and Installation Guide
Contents ZEPHYRONLINE.COM Page Safety Information............................................................................. 4-6 Types of Safety Warnings.................................................................... 4 General Safety...................................................................................4-5 Operation............................................................................................ 6 Electrical Requirements.........................................................
CORE Safety Information Z S A , Z A N , Z R V, Z R O WA L L READ AND SAVE THESE INSTRUCTIONS Your safety and the safety of others are very important. We have provided many important safety messages in this manual for your appliance. Always read and obey all safety messages. WARNING WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a) Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
Safety Information ZEPHYRONLINE.COM READ AND SAVE THESE INSTRUCTIONS WARNING WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWINGa: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. b) NEVER PICK UP A FLAMING PAN – You may be burned.
CORE Safety Information Z S A , Z A N , Z R V, Z R O WA L L READ AND SAVE THESE INSTRUCTIONS Operation ► Always leave safety grilles and filters in place. Without these components, operating blowers could catch onto hair, fingers and loose clothing. ► The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, maintenance and suitable use of the product.
List of Materials ZEPHYRONLINE.
CORE Installation Instructions Z S A , Z A N , Z R V, Z R O WA L L Ducting Calculation Sheet Equivalent number length x used = Duct pieces 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 900 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 450 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 900 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft.
Installation Instructions ZEPHYRONLINE.COM Mounting Height, Clearance, & Ducting A minimum of 6” round duct must be used to maintain maximum air flow efficiency. A n. mi . B n mi x. C a m D n. mi . E n mi x. F a m in. ” max. 4 2 ”m 34 ” If turns or transitions are required; install as far away from hood duct output and as far apart, between the two as possible. If available, also refer range manufacturer’s height clearance requirements and recommended hood mounting height above range.
CORE Installation Instructions Z S A , Z A N , Z R V, Z R O WA L L Ducting Options WARNING Fire Hazard: NEVER exhaust air or terminate ductwork into spaces between walls, crawl spaces, ceilings, attics, or garages. All exhaust must be ducted to the outside, unless using the recirculating option. ► Use single wall rigid metal ductwork only. ► Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Installation Instructions ZEPHYRONLINE.COM ZSA Hood Specifications TOP C/L 3-7/16” 6” 1/2” FRONT SIDE 7-7/16” 9” STANDARD min. ducted - 29” min. recirc. - 32” max. - 45” 1” 11-15/16” Z1C-01SA, Z1C-01SAB Z1C-01SAW, Z1C-01SABS EXTENSIONS min. ducted - 45-1/2” min. recirc. - 50” max.
CORE Installation Instructions Z S A , Z A N , Z R V, Z R O WA L L ZAN Hood Specifications 3-15/16” 9-1/2” TOP 1” 1-3/16” 6” 1” FRONT SIDE 10-5/8” 6-1/4” 10-3/8” (24”) 23-7/8”, (30”) 29-7/8”, (36”) 35-1/2” 12 Z1C-00AN, Z1C-00ANBS EXTENSIONS min. ducted - 43” min. recirc. - 47” max. - 81” 5-5/16” 17-7/8” 1-3/16” STANDARD min. ducted - 27” min. recirc. - 31” max.
Installation Instructions ZEPHYRONLINE.COM ZRV Hood Specifications TOP 6” AC In FRONT 3-15/16” 9-1/2” 1-1/8” SIDE 10-3/8” 6-1/4” 10-9/16” STANDARD min. ducted - 23” min. recirc. - 27-1/2” max. - 42 1/2” 15-5/16” Z1C-00RV, Z1C-00RVBS min. ducted - 41” min. recirc. - 46” max.
CORE Installation Instructions Z S A , Z A N , Z R V, Z R O WA L L ZRO Hood Specifications 6” 2-5/8” 2-3/8” 5-5/8” 3-9/16” TOP C/L FRONT SIDE 14-1/8” 11” (36”) 35-7/16”, (30”) 29-15/16” 14 Z1C-00RO EXTENSION min. ducted - 41” min. recirc. - 45” max. - 77” 3” 10-5/8” STANDARD min. ducted - 26-1/2” min. recirc. - 30-1/2” max.
Installation Instructions ZEPHYRONLINE.COM Electrical Supply WARNING Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring. For personal safety, remove house fuse or open circuit breaker before beginning installation. Do not use extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
CORE Installation Instructions Z S A , Z A N , Z R V, Z R O WA L L Mounting the Hood CAUTION Duct Cover Bracket At least two installers are required due to the weight and size of the hood. 1. Measure from range top to hood bottom and mark line A (24” minimum from range top). 2. Plum and mark center line. 24” min. 3. Mark hood height line B. ZAN : 18-7/16” from line A ZSA : 9-1/2” from line A ZRV : 15-7/8” from line A ZRO : 11-3/8 from line A 4. Mark mounting spread from C/L.
Installation Instructions ZEPHYRONLINE.COM Mounting the Hood 12. ZRV : Lilft glass canopy and place on top of hood body, secure glass canopy to hood body by (4) 3/16 x 1/4 screws. Hand tighten screws. 13. * If using hood in recirculating mode you must secure the air diverter plate onto wall before installing duct work and duct covers. You will also need to install charcoal filters and brackets. Turn to page 18 for more details.
CORE Installation Instructions Z S A , Z A N , Z R V, Z R O WA L L Recirculating Kit Installation (required if no ducting is used) 1. Purchase recirculating kit per the part number on the table. 2. Secure air diverter plate to wall below duct cover bracket. Run 6” ducting from top of hood and secure to air diverter plate (FIG. C). 3. ZAN: Remove aluminum mesh filters from hood. Secure charcoal filters to back side of aluminum mesh filter by 3 brackets (FIG C2). 4.
Features & Controls ZEPHYRONLINE.COM ICON Touch Controls Power / Delay Off Adjust 5 Speed Levels Lights Low/High/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
CORE Features & Controls Z S A , Z A N , Z R V, Z R O WA L L ICON Touch Controls 3 LIGHTS BUTTON - Lights have two levels, Low and High. - From off, press one time for Low. Press again for High. Press again to power lights off. 4 DISPLAY INDICATORS Mesh Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the mesh filters. - To reset: With hood off: hold the button for three seconds.
Features & Controls ZEPHYRONLINE.COM Optional RF Remote Control To enable RF remote control capabilities, the remote control accessory kit is required. The part number for the kit is RC-0002. FCC Caution To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example use only shielded interface cables when connecting to computer or peripheral device.
CORE Features & Controls Z S A , Z A N , Z R V, Z R O WA L L Optional RF Remote Control RF Remote Features The RF remote control is equipped with a magnet on the back for easy storage. The remote may be placed on any magnetic surface such as a refrigerator or the Zephyr remote holder, FIG. D. The remote holder can be inserted into a standard electrical outlet for easy storage. Note: The remote holder does not charge the RF remote. Maximum remote control communication distance is 15 feet from the liner.
Maintenance ZEPHYRONLINE.COM Hood & Filter Cleaning Surface Maintenance ► Do not use corrosive detergents, abrasive detergents or oven cleaners. ► Do not use any product containing chlorine bleach or any product containing chloride. ► Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth. Always rub in the direction of the stainless steel grain.
CORE Maintenance Z S A , Z A N , Z R V, Z R O WA L L Installing the Grease Filters (FIG. F): 1. Pull down on filter latch to release the filter tabs. 2. Pull down on front of filter to remove the grease filters. FIG. F LumiLight LED In the unlikely event that your LumiLight LED fails, please contact Zephyr to order replacement parts. See the list of parts and accessories page for part numbers and contact information. LED Removal (FIG. G): 1. Remove grease filters. 2.
ACT™ Conversion ZEPHYRONLINE.COM Airflow Control Technology (ACT™) Some local codes limit the maximum amount of CFM a range hood can move. ACT™ allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT™ enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels; 390 or 290 CFM. The usage of ACT™ may not be necessary for your installation.
CORE ACT™ Conversion Z S A , Z A N , Z R V, Z R O WA L L Enabling ACT™ To enable ACT™: 1. Before hood installation, gain access to PC board by following the steps shown on FIG. H. 2. Change plastic jumper positioning as shown in FIG. I to set the desired maximum blower CFM. 3. Re-install PC board and continue with hood installation. 4. Remove the appropriate foil CFM sticker included with the hood literature and place inside the hood body below the wiring diagram or in another clearly visible location.
Wiring Diagram ZEPHYRONLINE.COM ZSA, ZAN, ZRV, ZRO Wiring Diagram Volts Hz 120 60 Max Amps 4 Green Body Red Motor Red Yellow Blue Brown Grey Yellow Yellow Yellow White Yellow Control White Black Green Body For 30” & 36” models only REMARKS: CONDENSER 12.5+12.5uF 250VAC FIT AC120V 60Hz Power consumption shown for default CFM blower configuration ACT 390 CFM - Fan Max. @2.3A ACT 290 CFM - Fan Max. @1.
CORE Troubleshooting Z S A , Z A N , Z R V, Z R O WA L L Possible Problem After installation, the unit doesn’t work. Light works, but blower is not turning. The unit is vibrating. Possible Cause The power source is not turned ON. The power line and the cable locking connector is not connecting properly. The switch board or control board is defective. The switch board or control board wirings are disconnected. The blower is defective, possibly seized.
Troubleshooting ZEPHYRONLINE.COM Possible Problem The hood is not venting out properly. Filter is vibrating. RF Remote control does not work. Possible Cause Solutions Using the wrong size of ducting. Change the ducting to the correct size The hood might be hanging to high from the cook top. Adjust the distance between the cooktop and the bottom of the hood within 24” to 34” range. Close all the windows and doors to eliminate the outside wind flow.
CORE List of Parts & Accessories Z S A , Z A N , Z R V, Z R O WA L L Description Replacement Parts LumiLight LED, 6W ZSA ZRV ZRO Charcoal Filter (each) ZAN Charcoal Filter (each) ZSA Aluminum Mesh Filter (each) ZAN Aluminum Mesh Filter (each) ZRV Aluminum Mesh Filter (each) ZRO Aluminum Mesh Filter (each) Part Number Z0B0050 Z0F-C002 Z0F-C091 50200011 50200059 50200044 50200053 ZSA Optional Accessories SS Extension Duct Cover BLK Extension Duct Cover WHT Extension Duct Cover BLK SS Extension Duct Cover
Limited Warranty ZEPHYRONLINE.COM Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS United States Customers please call: 1-888-880-8368 or contact us at: zephyronline.com/contact Canada Customers please call: 1-800-361-0799 or Email: service@distinctive-online.
CORE Product Registration Z S A , Z A N , Z R V, Z R O WA L L Congratulations on the purchase of your Zephyr product! Please take a moment to register your new Zephyr product at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
WWW.ZEPHYRONLINE.COM Savona ZSA-E30FB, ZSA-E30FW, ZSA-E30FS, ZSA-E30FBS, ZSA-M90FB, ZSA-M90FW, ZSA-M90FS, ZSA-M90FBS Anzio ZAN-E24DS, ZAN-E30DS, ZAN-E30DBS, ZAN-M90DS ZAN-M90DBS Ravenna ZRV-E30CGC, ZRV-E30CGG, ZRV-E30CBSGG, ZRV-M90CGC, ZRV-M90CGG, ZRV-M90CBSGG Roma ZRO-E30FS, ZRO-M90FS EN Use, Care, and Installation Guide FR Guide d’utilisation, d’entretien et d’installation C TM Airflow Control Technology MAR22.
CORE Z S A , Z A N , Z R V, Z R O MUR 2 ZSA, ZAN, ZRV, ZRO Guide d’utilisation, d’entretien et d’installation
Table des matières ZEPHYRONLINE.COM Page Consignes de sécurité........................................................................ 4-6 Types d’avertissements de sécurité...................................................... 4 Sécurité générale................................................................................4-5 Opération............................................................................................ 6 Exigences électriques.......................................................
CORE Consignes de sécurité Z S A , Z A N , Z R V, Z R O MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Votre sécurité et celle des gens qui vous entourent sont très importantes. Ce manuel contient de nombreux messages de sécurité relatifs à votre appareil. Lisez tous les messages et conformez-vous-y en tout temps.
Consignes de sécurité ZEPHYRONLINE.
CORE Consignes de sécurité Z S A , Z A N , Z R V, Z R O MUR LISEZ ET CONSERVEZ CES INSTRUCTIONS Opération ► Laissez toujours les grilles de sécurité et les filtres en place. Sans ces composants, les soufflantes en fonctionnement pourraient s’accrocher aux cheveux, aux doigts et aux vêtements amples. ► Le fabricant décline toute responsabilité en cas de non-respect des instructions données ici pour l’installation, la maintenance et l’utilisation appropriée du produit.
Liste de matériel ZEPHYRONLINE.
CORE Instructions d’installation Z S A , Z A N , Z R V, Z R O MUR Feuille de calcul pour le conduit d’aération Longueur x Nombre utilisé Pièces de conduit = 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" pi 16 pi 6” circ. à rect. de 3-1/4" x 10", coude à 90º pi 7” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect.
Instructions d’installation ZEPHYRONLINE.COM Hauteur de montage, dégagement et gaine A n. mi . B n mi x. C a m D n. mi . E n mi x. F a m in..
CORE Instructions d’installation Z S A , Z A N , Z R V, Z R O MUR Options de conduits ATTENTION Risque d’incendie: NE JAMAIS évacuer l’air ni terminer de conduits dans des espaces entre les murs, les vides sanitaires, les plafonds, les greniers ou les garages. Tout l’échappement doit être canalisé vers l’extérieur, à moins d’utiliser l’option de recirculation. ► Utilisez uniquement des conduits métalliques rigides à paroi simple.
Instructions d’installation ZEPHYRONLINE.COM ZSA Spécifications de la hotte HAUT C/L 3-7/16 po 6 po 1/2 po DE FACE CÔTÉ 7-7/16 po 9 po 11-15/16 po LA NORME min. canalisé - 29 po min. recirc. - 32 po max. - 45 po 1 po Z1C-01SA, Z1C-01SAB Z1C-01SAW, Z1C-01SABS PROLONGATIONS min. canalisé - 45-1/2 po min. recirc. - 50 po max.
CORE Instructions d’installation Z S A , Z A N , Z R V, Z R O MUR ZAN Spécifications de la hotte 3-15/16 po 9-1/2 po HAUT 1” 1-3/16 po 6 po 1 po CÔTÉ 10-3/8 po 10-5/8 po 6-1/4 po DE FACE (24 po) 23-7/8 po (30 po) 29-7/8 po (36 po) 35-1/2 po 12 5-5/16 po 17-7/8 po 1-3/16 po LA NORME min. canalisé - 27 po min. recirc. - 31 po max. - 48-1/2 po RALLONGES Z1C-00AN, Z1C-00ANBS min. canalisé - 43 po min. recirc. - 47 po max.
Instructions d’installation ZEPHYRONLINE.COM ZRV Spécifications de la hotte HAUT o 6p AC In DE FACE 3-15/16 po 9-1/2 po 1-1/8 po CÔTÉ 10-3/8 po 6-1/4 po 10-9/16 po LA NORME min. canalisé - 23 po min. recirc. - 27-1/2 po max. - 42 1/2 po 15-5/16 po Z1C-00RV, Z1C-00RVBS min. canalisé - 41 po min. recirc. - 46 po max.
CORE Instructions d’installation Z S A , Z A N , Z R V, Z R O MUR HAUT 6p 5-5/8 po 2-3/8 po o 3-9/16 po ZRO Spécifications de la hotte 2-5/8 po C/L DE FACE CÔTÉ 14-1/8 po 11 po (36 po) 35-7/16 po, (30 po) 29-15/16 po 14 PROLONGATION Z1C-00RO min. canalisé - 41 po min. recirc. - 45 po max. - 77 po 3 po 10-5/8 po LA NORME min. canalisé - 26-1/2 po min. recirc. - 30-1/2 po max.
Instructions d’installation ZEPHYRONLINE.COM Fourniture électrique ATTENTION Le câblage électrique doit être effectué par des personnes qualifiées conformément à tous les codes et normes applicables. Cette hotte doit être correctement mise à la terre. Coupez l’alimentation électrique à l’entrée de service avant le câblage. Pour votre sécurité personnelle, retirez le fusible de la maison ou ouvrez le disjoncteur avant de commencer l’installation.
CORE Instructions d’installation Z S A , Z A N , Z R V, Z R O MUR Montage de la hotte AVERTISSEMENT Support de couvercle de conduit Au moins deux installateurs sont nécessaires en raison du poids et de la taille de la hotte. 1. Mesurez du haut de la cuisinière au bas de la hotte et marquez la ligne A (minimum de 24 po à partir du haut de la cuisinière). 2. Ligne médiane prune et marque. 24 po min. 3. Marquez la hauteur de la hotte ligne B.
Instructions d’installation ZEPHYRONLINE.COM Mounting the Hood 10. Allumez la hotte et vérifiez s’il y a des fuites autour du ruban adhésif. 11. Placez les couvercles de conduit télescopiques sur la hotte et étendez le couvercle de conduit intérieur (supérieur) vers le haut et fixez-le au support de couvercle de conduit à l’aide de (2) vis M4 x 8. Réinstallez les filtres à mailles. 12.
CORE Instructions d’installation Z S A , Z A N , Z R V, Z R O MUR Installation du kit de recirculation (requis si aucun conduit n’est utilisé Pour des instructions d’installation détaillées, veuillez vous référer au manuel inclus avec le kit de recirculation. Le kit comprend les filtres à charbon, les supports de filtre à charbon et la plaque de dérivation d’air.
Fonctionnalités et commandes ZEPHYRONLINE.COM Commandes tactiles ICÔNE Mise en marche/Arrêt à retardement Choix de 5 vitesses Lumières: faible / élevée / éteinte Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
CORE Fonctionnalités et commandes Z S A , Z A N , Z R V, Z R O MUR Commandes tactiles ICÔNE 3 TOUCHE DE CONTRÔLE DES LUMIÈRES - Il existe deux intensités: basse et haute. - Lorsque les lumières sont éteintes, appuyez une fois pour les allumer à faible intensité. Appuyez à nouveau pour les mettre en hauteur. Appuyez à nouveau pour les désactiver.
Fonctionnalités et commandes ZEPHYRONLINE.COM Télécommande RF en option Pour activer les capacités de télécommande RF, le kit d’accessoires de télécommande est requis. Le numéro de pièce du kit est RC-0002. Attention FCC Pour assurer la conformité continue, tout changement ou modification non expressément approuvé par la partie responsable de la conformité peut annuler le droit de l’utilisateur à utiliser cet équipement.
CORE Fonctionnalités et commandes Z S A , Z A N , Z R V, Z R O MUR Télécommande RF en option Caractéristiques de la télécommande RF La télécommande RF est équipée d’un aimant à l’arrière pour un rangement facile. La télécommande peut être placée sur n’importe quelle surface magnétique telle qu’un réfrigérateur ou le support de télécommande Zephyr, FIG. D. Le support à distance peut être inséré dans une prise électrique standard pour un rangement facile.
Entretien ZEPHYRONLINE.COM Nettoyage de la hotte et du filtre Entretien de surface ► N’utilisez pas de détergents corrosifs, de détergents abrasifs ou de nettoyants pour four. ► N’utilisez aucun produit contenant un agent de blanchiment chloré ou un produit contenant du chlorure. ► N’utilisez pas de laine d’acier ou de tampons à récurer abrasifs qui pourraient rayer et endommager la surface.
CORE Entretien Z S A , Z A N , Z R V, Z R O MUR Installation des filtres à graisse (FIG. F): 1. Tirez sur le loquet du filtre pour libérer les languettes du filtre. 2. Tirez sur le devant du filtre pour retirer les filtres à graisse. FIG. F LumiLight LED Dans le cas peu probable où votre LED LumiLight tomberait en panne, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la page de la liste des pièces et accessoires pour les numéros de pièces et les coordonnées.
Conversion ACT™ ZEPHYRONLINE.COM Technologie de contrôle du flux d’air (ACT™) Certains codes locaux limitent la quantité maximale de CFM qu’une hotte de cuisine peut déplacer. ACT™ vous permet de contrôler le CFM maximum du ventilateur de certaines hottes de cuisinière Zephyr Ventilation sans avoir besoin de trousses d’air d’appoint coûteuses. ACT™ permet à l’installateur de régler facilement la vitesse maximale du ventilateur sur l’un des deux niveaux CFM les plus couramment spécifiés ; 390 ou 290 PCM.
CORE Conversion ACT™ Z S A , Z A N , Z R V, Z R O MUR Activer ACT™ Pour activer ACT™ : 1. Avant l’installation de la hotte, accédez au tableau de circuits imprimés en suivant les étapes indiquées sur la FIG. H. 2. Modifiez la position du cavalier en plastique comme indiqué sur la FIG. I pour régler le CFM maximum désiré du ventilateur. 3. Réinstallez la carte de circuit imprimé et continuez l’installation de la hotte. 4.
Schéma de câblage ZEPHYRONLINE.COM ZSA, ZAN, ZRV, ZRO Schéma Volts Hz 120 60 Max Amps 4 Corps Vert Rouge Blanc Jaune Jaune Jaune Moteur Rouge Jaune Bleu Marron Gris Jaune Contrôler Blanc Noir Vert Corps Pour les modèles 30 po et 36 po uniquement REMARQUES : CONDENSEUR 12.5+12.5uF 250VAC FIT AC120V 60Hz Consommation d’énergie indiquée pour la configuration par défaut du ventilateur CFM ACT 390 CFM - Ventilateur max. @2.3A ACT 290 CFM - Ventilateur Max. @1.
CORE Dépannage Z S A , Z A N , Z R V, Z R O MUR Problème possible Après l'installation, l'unité ne fonctionne pas. Cause possible Solutions La source d'alimentation n'est pas allumée. La ligne d'alimentation et le connecteur de verrouillage du câble ne se connectent pas correctement. Le tableau de commande ou le tableau de commande est défectueux. Les câblages du tableau de commande ou du tableau de commande sont déconnectés. Assurez-vous que le disjoncteur et l’appareil sont sous tension.
Dépannage ZEPHYRONLINE.COM Problème possible Cause possible Solutions La hotte ne s'échappe Utilisation de la mauvaise taille de Changer la gaine à la bonne taille pas correctement. conduit. La hotte est peut-être suspendue trop haut de la table de cuisson. Réglez la distance entre la table de cuisson et le bas de la hotte dans une plage de 24 po à 34 po. Fermez toutes les fenêtres et portes pour éliminer le vent extérieur.
CORE Liste des pièces et accessoires Z S A , Z A N , Z R V, Z R O MUR La description Pièces de rechange LumiLight LED, 6W Filtre à charbon ZSA ZRV ZRO (chacun) Filtre à charbon ZAN (chacun) Filtre à mailles en aluminium ZSA (chacun) Filtre à mailles en aluminium ZAN (chacun) Filtre à mailles en aluminium ZRV (chacun) Filtre à mailles en aluminium ZRO (chacun) Numéro d’article Z0B0050 Z0F-C002 Z0F-C091 50200011 50200059 50200044 50200053 Accessoires optionnels ZSA SS Couverture de conduit d’extension BL
Garantie limitée ZEPHYRONLINE.COM Garantie limitée POUR OBTENIR UN SERVICE SOUS GARANTIE OU POUR TOUTE QUESTIONS LIÉES AU SERVICE Les clients des États-Unis doivent appeler le: 1-888-880-8368 ou nous contacter à: zephyronline.com/contact Clients du Canada, veuillez appeler: 1-800-361-0799 ou par courriel: service@distinctive-online.
CORE Enregistrement du produit Z S A , Z A N , Z R V, Z R O MUR Nous vous félicitons d’avoir acheté une produit Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle produit au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.