Owner Manual

14
www.zephyronline.com
'XFWOHVVUHFLUFXODWLRQLVLQWHQGHGIRUDSSOLFDWLRQVZKHUHDQH[KDXVWGXFWZRUNLVQRWSRVVLEOHWREHLQVWDOOHG
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust
IURPFRRNLQJDUHGUDZQDQG¿OWHUHGE\DVHWRIRSWLRQDOFKDUFRDO¿OWHUV7KHDLULVWKHQSXUL¿HGDQGUH
FLUFXODWHGEDFNZLWKLQWKHKRPH
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct
ZRUNLISRVVLEOH7KHKRRGLVPRVWHႇHFWLYHDQGHႈFLHQWDVDQH[KDXVWKRRG2QO\ZKHQWKHH[KDXVWRSWLRQ
is not possible should you recourse to converting the hood into a recirculating hood.
:KHQFRQYHUWHGWREHDUHFLUFXODWLQJKRRGDVHWRIFKDUFRDO¿OWHUVDUHUHTXLUHGRQWRSRILWVVWDQGDUG
DOXPLQXPPHVK¿OWHUVHW2UGHUDFFRUGLQJWRLWVSDUWQXPEHUEHORZ7KHVWDQGDUGDOXPLQXPPHVK¿OWHUVDUH
LQWHQGHGWRFDSWXUHUHVLGXHIURPFRRNLQJDQGWKHRSWLRQDOFKDUFRDO¿OWHUVKHOSWRSXULI\IXPHVH[KDXVWHGIURP
FRRNLQJIRUUHFLUFXODWLRQ
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
.LWLQFOXGHVFKDUFRDO¿OWHU¿OWHUDWWDFKPHQWFOLSDQGDLUGLYHUWHUSODWH
Hood Models Part No. Filters in pkg.
ZAZ ZRC-02AZ 2
ZLC ZRC-00LC 1
ZRM-E36DS ZRC-02RM 2
ZRM-E42DS ZRC-01RM 3
ZRE ZRC-00RE 2
3XUFKDVHUHFLUFXODWLQJNLWSHUWKHSDUWQXPEHUDERYH
2. Secure air diverter plate to top support frame. Open sides of air diverter plate should face left and right
to direct air through the louver holes located on the top duct cover. Run 6” ducting from top of hood and
secure to air diverter plate.
 5HPRYHPHVK¿OWHUVIURPKRRG,QVWDOOFKDUFRDO¿OWHUVDVUHIHUHQFHGZLWKWKHPDQXDOLQFOXGHGZLWK
UHFLUFXODWLRQNLW
5H,QVWDOOPHVK¿OWHUV
7XUQRQFKDUFRDO¿OWHUFKDQJHLQGLFDWRURQFRQWUROSDQHO5HIHUWRGHWDLOVRQSDJH7KH
PLFURSURFHVVRULQWKHFRQWUROVZLOOLQGLFDWHWKHQHHGWRFKDQJHWKHFKDUFRDO¿OWHUDIWHUKRXUVRI
FRQWLQXRXVXVH2UGHUUHSODFHPHQWFKDUFRDO¿OWHUVSHUWKHOLVWEHORZ
&KDUFRDO¿OWHUVPXVWEHUHSODFHGDIWHUHYHU\KRXUVRIXVHRUDSSUR[LPDWHO\HYHU\WRPRQWKV
EDVHGRQDQDYHUDJHRIKUVRIGDLO\FRRNLQJWLPH
NOTE: For more details refer to manual included with recirculation kit.
Charcoal Filter Replacements
Hood Model Part No. Qty to Order
ZAZ Z0F-C091 2
ZLC Z0F-C092 1
ZRM-E36DS Z0F-C002 2
ZRM-E42DS Z0F-C002 3
ZRE Z0F-C002 2
'2127:$6+&+$5&2$/),/7(56&KDUFRDO¿OWHUVPD\QHHG
WREHFKDQJHGPRUHRIWHQGHSHQGLQJRQFRRNLQJKDELWV
Installation – Ductless Recirculating