Use, Care, and Installation Guide www.zephyronline.com Genova ZGE-E30AS ZGE-E36AS ZGE-E30AS290 ZGE-E36AS290 Model number: Serial Number: APR19.0501 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... +RRG 6SHFL¿FDWLRQV ................................................... Preparing the Cabinet ............................................... Installing the Hood ...................................................... Ductless Recirculation ..............................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. Hood not intended for installation over an outdoor grill. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Installing the Hood www.zephyronline.com 0RXQWLQJ KHLJKW IURP WRS RI FRRNLQJ VXUIDFH WR bottom of hood should be no less than 24” and no more than 32”. It is important to install the hood at the proper mounting height. Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG ¿UH KD]DUG ZKLOH KRRGV mounted too high will be hard to reach and will ORVH SHUIRUPDQFH DQG HႈFLHQF\ If available, also refer to range manufacturer’s height clearance requirements and recommended KRRG PRXQWLQJ KHLJKW DE
1(9(5 H[KDXVW DLU RU WHUPLQDWH GXFW ZRUN LQWR VSDFHV EHWZHHQ ZDOOV FUDZO VSDFHV FHLOLQJ DWWLFV RU JDUDJHV All exhaust must be ducted to the outside, unless using the recirculating option. 8VH VLQJOH ZDOO ULJLG 0HWDO GXFWZRUN RQO\ )DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL¿HG 6LOYHU 7DSH RU 'XFW 7DSH Ducting Options Example roof pitch w/ flashing & cap side wall cap w/ gravity damper soffit or crawl space ductless recirculating ductless recirculating 7 soffit Ins
front of hood side of hood 1 9 2 " 242mm 3" 76mm 15 29 16 " 760mm 1 1" 8 28mm 11" 280mm 1 5" 8 41mm 11 19 16 " 500mm 7 35 8 " 912mm 1 11 4 " 286mm 6" 153mm 3 1 to 1 " 4 " 8 6mm 35mm top of hood junction box 5 8 " 16mm blower outlet 1 7 16 " 180mm 3 7 4 " 197mm m 3m 15 6" 1 5 17 2 " to 18 8 " 445mm 473mm Installation – +RRG 6SHFL¿FDWLRQV www.zephyronline.
7 3/4” 19-7/8” 8” 7/ 9- 1- 9/ 16 ” C/L Fig.1 front edge glass handle Fig.2 1. 'HWHUPLQH DQG PDUN FHQWHU OLQH RQ ZDOO DQG FDELQHW ERWWRP ZLWK D SHQFLO ,I WKH FDELQHW ERWWRP LV UHFHVVHG ZRRG EORFNLQJ PXVW EH LQVWDOOHG WR HQVXUH SURSHU DOLJQPHQW RI WKH KRRG ZLWK WKH FDELQHW ERWWRP :RRG EORFNLQJ VKRXOG EH ÀXVK within cabinet bottom. 3. Follow the dimensions in Fig.1 and cut-out the bottom of your cabinet to create an opening IRU WKH KRRG WR ¿W WKURXJK ,I \RX KDY
Installation – Installing the Hood www.zephyronline.com ! WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring. 1) Prepare electrical wiring and ducting in cabinet. Location of junction box and blower outlet can be found on page 8. Fig.3 Fig.4 2) Unscrew the (10) screws from front panel and place the panel aside, Fig.3.
Fig.7 Fig.8 3ODFH ORZHU LQVWDOODWLRQ EUDFNHWV XQGHU XSSHU LQVWDOODWLRQ EUDFNHWV ORFDWHG RQ OHIW DQG ULJKW VLGHV RI KRRG ERG\ Fig.7. Note: The wider portion of the lower installation EUDFNHW VKRXOG EH DW WKH ERWWRP 7) From inside the hood, secure (1) M4x8 screw into HDFK ORZHU LQVWDOODWLRQ EUDFNHW 7KH SRVLWLRQ RI WKLV screw is adjustable to accomodate various cabinet ERWWRP WKLFNQHVVHV )LJ 'R QRW IXOO\ WLJKWHQ VFUHZ \HW 2 1 A B Fig.
Installation – Installing the Hood www.zephyronline.com A Fig.11 Fig.12A 10) Place 6” round ducting over blower collar and secure with aluminum duct tape. If using hood in ductless recirculating mode turn to page 13. ,QVWDOO HOHFWULFDO ZLULQJ 1RWH $ FDEOH ORFN QRW LQFOXGHG PD\ EH UHTXLUHG E\ ORFDO FRGHV &KHFN with local requirements and codes, purchase and install appropriate connector if necessary.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct ZRUN LI SRVVLEOH 7KH KRRG LV PRVW HႇHFWLYH DQG HႈFLHQW DV DQ H[KDXVW KRRG 2QO\ ZKHQ WKH H[KDXVW RSWLRQ is not possible should you recourse to converting the hood into a recirculating hood.
Features & Controls – Touch Controls www.zephyronline.com Blower On/Off Display (speed level, delay off, filter clean/replace) Lights Normal/Dim/Off Speed Selection 5 Min Delay Off NOTE: Blower and lights will automatically shut off when the glass is closed. The hood also has a built in memory function that will automatically turn the blower and lights on at the last setting when the glass is pulled open. Blower will not operate while the glass is closed but the lights will still function.
Whether your hood is installed as an exhaust or purifying unit, a decorative mesh filter is fitted by the factory. This mesh filter is intended to filter out residue from cooking. It need not be replaced on a regular basis but is required to be kept clean. After every 30 hours of use the Filter Clean Reminder function in the microprocessor will automatically remind you by a flashing F when the mesh filter needs to be cleaned. The filter can be cleaned by hand with non-abrasive soap or in a dishwasher.
Features & Controls – Remote Control (Optional) www.zephyronline.com FCC Caution: 7R DVVXUH FRQWLQXHG FRPSOLDQFH DQ\ FKDQJHV RU PRGL¿FDWLRQV QRW H[SUHVVO\ DSSURYHG E\ WKH SDUW\ responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.
Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel &OHDQ SHULRGLFDOO\ ZLWK ZDUP VRDS\ ZDWHU DQG FOHDQ FRWWRQ FORWK RU PLFUR ¿EHU FORWK $OZD\V UXE LQ WKH direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. '2 127 WRXFK EXOE XQWLO VZLWFKHG Rႇ DQG FRROHG 7RXFKLQJ KRW EXOEV FRXOG FDXVH VHULRXV EXUQV 0DNH VXUH DOO SRZHU LV WXUQHG Rႇ DQG EXOEV DUH QRW KRW 5HPRYH E\ WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH %XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV stops and falls out. ,I EXOEV DUH GLႈFXOW WR WXUQ GXH WR SURORQJHG XVH ¿UPO\ DWWDFK D JODVV VXFWLRQ FXS DSSUR[LPDWHO\ WKH GLDPHWHU RI WKH EXOE
Maintenance – Wiring Diagram 3.5A 3.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR GENOVA Issue Cause What to do After installation, the unit doesn’t ZRUN 1. The power source is not turned ON. 0DNH VXUH WKH FLUFXLW EUHDNHU DQG WKH XQLW¶V power is ON. 7KH SRZHU OLQH DQG WKH FDEOH ORFNLQJ FRQQHFWRU is not connecting properly. &KHFN WKH SRZHU FRQQHFWLRQ ZLWK WKH XQLW LV connected properly. 3. The switch board and control board wirings are disconnected.
PART# Replacement Parts Light Bulb GU10 50W (each) Decorative Mesh Filter Z0B0020 50200036 Optional Accessories Recirculating Kit Replacement Charcoal Filter (each) RF Remote Control Bloom GU10 LED ZRC-00GE Z0F-C0GE 14000005 Z0B0040 To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
www.zephyronline.com Zephyr Ventilation, LLC (rHIHUUHG WR KHUHLQ DV ³ZH´ RU ³XV´ ZDUUDQWV WR Whe original consumer purchaser (referred to herein DV ³\RX´ RU ³\RXU´ RI =HSK\U SURGXFWV WKH ³3URGXFWV”) that such Products will be free from defects in materials or ZRUNPDQVKLS DV IROORZV Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parts (including LED light bulbs, if applicable) to replace
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 23 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Genova ZGE-E30AS ZGE-E36AS ZGE-E30AS290 ZGE-E36AS290 Numéro de modèle : Numéro de série : APR19.0501 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Feuille de calcul pour le conduit ........................... Espace libre et hauteur de montage ................... Options d’installation pour le conduit .................. 6SpFL¿FDWLRQV GH OD KRWWH......................................... Préparation de l’armoire........................................... Installation de la hotte.................................... Reprise d’air sans conduit ....................................... 5 6 7 8 9 10-12 13 COMMANDES &RPPDQGHV j HႉHXUHPHQW ......
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
Liste du matériel www.zephyronline.
= 1 pi x( ) = pi 6 po, 7 po, 8 po, 10 po circ., droit 1 pi x( ) = pi 3-1/ 4 po x 10 po rect., coude à 90º 15 pi x( ) = pi 3-1/ 4 po x 10 po rect., coude à 45º 9 pi x( ) = pi 3-1/ 4 po x 10 po rect., coude plat à 90º 24 pi 3-1/ 4 po x 10 po rect., droit x( 7 po to 6 po or 25 pi 8 po to 7 po circ. reducteur conique x( 15 pi 6 po, 7 po, 8 po circ. bouchone de l’air x( 6 po, 7 po, 8 po, 10 po circ.
Installation – Espace libre et hauteur de montage www.zephyronline.com Il est important d’installer la hotte à la hauteur de montage adéquate.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
Installation – 6SpFL¿FDWLRQV GH OD KRWWH www.zephyronline.
7 3/4” 19-7/8” 98” 7/ 1- 9/ 16 ” C/L Fig.1 Fig.2 1. Calculez et marquez la ligne centrale sur le mur et sur le bas de l’armoire avec un crayon. 2. Si le bas de l’armoire est enfoncé, vous devrez installer des blocs de bois pour aligner correctement le bas de l’armoire avec la hotte. Les blocs de bois devraient arriver à ras du bas de l’armoire. 3. Respectez les dimensions de la Fig.1 et coupez le bas de l’armoire pour créer une ouverture permettant l’installation de l’armoire.
Installation – Installation de la hotte www.zephyronline.com 1) Préparez le câblage électrique et le conduit dans l’armoire. Les emplacements de la boîte de connexion et l’ouverture de refoulement de ventilateur sont indiqués à la page 8. Fig.3 Fig.4 2) Dévissez les (10) vis du panneau avant et laissez le panneau de côté, Fig.3. Vous aurez maintenant accès à l’intérieur de la hotte. 3) Ouvrez les portes de l’armoire.
Fig.7 Fig.8 6) Placez les supports d’installation inférieurs sous les supports d’installation supérieurs situés sur les côtés gauche et droit du boîtier de la hotte, Fig.7. Note : La partie plus large des supports d’installation inférieurs devrait se trouver au bas de la hotte. ¬ SDUWLU GH O¶LQWpULHXU GH OD KRWWH ¿[H] YLV 0 [ GDQV chaque support d’installation inférieur. La position de ces YLV HVW DMXVWDEOH HW V¶DGDSWH j GLႇpUHQWHV pSDLVVHXUV GH dessous d’armoire, Fig.8.
Installation – Installation de la hotte www.zephyronline.com A Fig.11 Fig.12A 10) Placez le conduit circulaire de 6” par-dessus le collier GX YHQWLODWHXU HW ¿[H] OH WRXW DYHF GX UXEDQ j FRQGXLW HQ aluminium. Si vous utilisez la hotte en mode de reprise d’air, allez à la page 13. 11) Secure (2) 1 “vis à bois (A) dans les trous de vis sur les F{WpV JDXFKH HW GURLW GH O¶RXYHUWXUH GX ¿OWUH $LQVL SRXUUD le corps de la hotte à la base du cabinet et de prévenir le capot de se déplacer après installation.
Nous recommandons de TOUJOURS évacuer l’air à l’extérieur de la maison en utilisant le conduit en place ou, s’il y a SRVVLELOLWp HQ LQVWDOODQW XQ QRXYHDX FRQGXLW /D KRWWH HVW SOXV HႈFDFH ORUVTX¶XWLOLVpH FRPPH V\VWqPH G¶pYDFXDWLRQ G¶DLU 9RXV QH GHYULH] UHFRXULU j OD FRQ¿JXUDWLRQ GH UHSULVH G¶DLU TXH ORUVTX¶LO HVW LPSRVVLEOH G¶LQVWDOOHU XQ FRQGXLW G¶DpUDWLRQ /RUVTXH OD FRQ¿JXUDWLRQ GH UHSULVH G¶DLU HVW FKRLVLH XQ ¿OWUH j FKDUERQ GRLW rWUH LQVWDOOp VXU OH ¿OWUH j WDPLV GpFRUDWLI &RPPDQGH] OHV HQ YRXV U
Commandes - &RPPDQGHV j HႉHXUHPHQW www.zephyronline.
15 Commandes – ,QGLFDWHXU GH FKDQJHPHQW GHV ¿OWUHV j FKDUERQ
COMMANDES – ,QGLFDWHXU GH QHWWR\DJH GHV ¿OWUHV j WDPLV PpWDOOLTXHV www.zephyronline.
FRQWLQXH WRXWH PRGL¿FDWLRQ DSSRUWpH VDQV O¶DSSUREDWLRQ H[SUHVVH GX SDUWL UHVSRQVDEOH GH OD FRQIRUPLWp SRXUUDLW DQQXOHU l’autorisation de l’utilisateur de faire fonctionner cet appareil. Cet appareil respecte l’article 15 des réglementations FCC.
Entretien – 1HWWR\DJH GHV ¿OWUHV HW GH OD KRWWH www.zephyronline.com ENTRETIEN DES SURFACES 1HWWR\H] UpJXOLqUHPHQW OHV VXUIDFHV GH OD KRWWH DYHF GH O¶HDX VDYRQQHXVH FKDXGH HW XQ FKLႇRQ GH FRWRQ propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
Attention : Les ampoules deviennent extrêmement chaudes lorsqu’allumées. Veuillez NE PAS les toucher avant de les avoir éteintes et laissées refroidir. Le contact avec les ampoules chaudes pourrait causer de sérieuses brûlures. Assurez-vous que l’alimentation électrique est coupée et que les ampoules ne sont pas chaudes. Enlevez les ampoules en les dévissant dans le sens contraire des aiguilles d’une montre.
Entretien – Schéma de câblage www.zephyronline.com 3.5A 3.
Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur et de l’appareil est allumée 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés 9pUL¿H] TXH OH EUDQFKHPHQW GH O¶DSSDUHLO D pWp fait correctement.
Listes des pièces et des accessoires www.zephyronline.com DESCRIPTION NO DE PIÈCE Pièces de remplacement Ampoule GU10 50W (chaque) Filtre à tamis décoratif Z0B0020 50200036 Accessoires optionnels Ensemble de reprise d’air Filtres à charbon de remplacement (chaque) Commande à distance radioélectrique ZRC-00GE Z0F-C0GE 14000005 Pour commander des pièces, visitez-nous en ligne au www.zephyronline.
AGRAFEZ VOTRE REÇU ICI Garantie limitée Une preuve de la date d’achat originale est nécessaire pour obtenir du service lorsque le produit est sous garantie POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits so
www.zephyronline.com ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.