Use and Care Manual

9
1. Measure from range top to hood bottom and mark line A.
(26” minimum from range top) .
2. Plum and mark center line.
3. Mark hood height line B. (14-5/8” from line A)
4. Mark mounting spread from C/L. (8-15/16” on line B)
5. Fasten (2) M4 x 1-1/2” screws into studs on line B but
do not tighten all the way. Note: Wood blocking may
need to be added behind the drywall if no studs are
present. Wall anchors may also be used but check
local codes for compliance. Failure to use suitable
wall anchors and screws to hold the weight of the
hood could result in personal injury or damage to
the cooking surface or counter.
6. Remove tape and securing electronics mounting bracket
to hood. Reposition electronics mounting bracket as
shown in (FIG B.) and secure to motor housing using (2)
pre installed screws (FIG B-3).
6. Remove the (2) aluminum mesh lters.
7. Hang hood onto the mounting screws and hand tighten
each screw. (Fig A)
8. Center and attach duct cover mounting bracket to wall
just below the ceiling or so󰀩t using (2) M4 x 1” screws.
9. Install electrical (FIG B-2) and duct work. Seal duct work
with aluminum duct tape.
10. Power up hood and check for leaks around duct tape.
11. Place telescopic duct covers onto hood and extend
inner (top) duct cover upwards and secure to duct cover
bracket using (2) M4 x 8 screws. Reinstall mesh lters.
* If using hood in recirculating mode you must secure the
air diverter plate onto wall before installing duct work and
duct covers. You will also need to install charcoal lters
and brackets. Turn to page 10 for more details.
26” min.
8-
15/16
14-
5/8
CAUTION: At least two installers are required
due to the weight and size of the hood.
!
WARNING: Electrical wiring must be done by a qualified person(s) in
with all applicable codes and standards. This range hood must be
Cable Lock
2
1
3
Motor Housing
Cable Lock
A cable locking connector (not supplied) might
be required by local codes. Check with local
requirements and codes, purchase and install
appropriate connector if necessary.
Installation – Mounting the Hood
FIG. A
FIG. B