Use, Care, and Installation Guide www.zephyronline.com Roma Island ZRM-E36AS ZRM-E42AS Model number: Serial Number: SEP07.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... +RRG 6SHFL¿FDWLRQV ................................................... Mounting the Range Hood ...................................... Mounting the Hood and Duct Cover ................... Ductless Recirculation .............................................. 5 6 7 8 9 10 11 CONTROLS..............
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.com MODEL: ZRM-E36AS, ZRM-E42AS 2 Thick Trim Pieces 2 Top Duct Covers 1 Top Support Frame 2 Thin Trim Pieces 1 Bottom Support Frame 2 Bottom Duct Covers 1 Hood 4 Halogen Light Bulbs (pre-installed) 2 Metal Filters (3 - ZRM-E42AS) HARDWARE PACKAGE CONTENTS 3 Wire Nuts 4 M6*50 Wood Screws 1 Damper with 2 clips 4 ø14 OD / ø6.5 ID Washers 4 M5 Wing Nuts 10 M4*8 Philips Head Screws 12 M3*2.5 Philips Head Screws note: hardware is in metric measurements.
Equivalent number length x used = Duct pieces Total Total 3-1/ 4” x 10” 1 Ft. Rect., straight x( ) = Ft. 6”- 8” Round 30 Ft. wall cap with damper x( ) = Ft. 7” Round, straight 1 Ft. x( ) = Ft. 6”- 8” Round, 30 Ft. roof cap x( ) = Ft. 8” Round, straight 1 Ft. x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. 3-1/ 4” x 10” 15 Ft. Rect.90 0 elbow x( ) = Ft. x( ) = Ft. 3-1/ 4” x 10” 9 Ft. Rect.45 0 elbow x( ) = Ft. 6” round to 16 Ft.
Installation – Mounting Height & Clearance www.zephyronline.com Minimum mount height between range top to hood bottom should be no less than 28”. min. ducted min. recirc. max. Maximum mount height should be no higher than 36”. 28” 32“ 39” It is important to install the hood at the proper mounting height. Hoods mounted too low could UHVXOW LQ KHDW GDPDJH DQG ¿UH KD]DUG ZKLOH KRRGV mounted too high will be hard to reach and will ORRVH LWV SHUIRUPDQFH DQG HI¿FLHQF\ 4” min. 28” max. 36” min.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only.
Front of Hood Side of Hood 14” 12” (blower housing) min. ducted 28” min. recirc. 32” max. 39” 11 5/8” 4” 27” 36” or 42” Top of Hood (blower housing) Top Support Frame (ceiling bracket) 12 3/8” electrical K/O 10 1/8” 8” 1 5/8” 8 3/4” 7/ 10 3/4” ø5 7 1/8” 3/4” 3” C/L 7 7/8” 1/4” FRONT 1/ 8” FRONT 1 4 1/2” Installation – +RRG 6SHFL¿FDWLRQV www.zephyronline.
Wood Blocking 1 Fro nt 2 Top Support Frame 3 Bottom Support Frame 4 5 6 Hood ! CAUTION: At least two installers are required due to the weight and size of the hood. $GG DQG VHFXUH ZRRG EORFNLQJ minimum 2 x 4 RQWR FHLOLQJ MRLVWV 2. Fasten top support frame to desired location on ceiling using 4 2” wood screws with washers. The wider section of the support bracket faces the front of the hood. 3.
Installation – Mounting the Hood and Duct Cover www.zephyronline.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct ZRUN LI SRVVLEOH 7KH KRRG LV PRVW HIIHFWLYH DQG HI¿FLHQW DV DQ H[KDXVW KRRG 2QO\ ZKHQ WKH H[KDXVW RSWLRQ is not possible should you recourse to converting the hood into a recirculating hood. :KHQ FRQYHUWHG WR EH D UHFLUFXODWLQJ KRRG D VHW RI FKDUFRDO ¿OWHUV DUH UHTXLUHG RQ WRS RI LWV VWDQGDUG 0HWDO Filter set. Order according to its Part number below.
Controls www.zephyronline.
Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.
Maintenance – Lights www.zephyronline.com REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. 5HPRYH E\ WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH %XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV stops and falls out.
Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The switch board and control board wirings are disconnected. 3. Make sure the wirings between the switch board and control board are connected properly.
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART# Replacement Parts /LJKW %XOE 05 *8 : HDFK 0HWDO )LOWHU HDFK = % 6 Optional Accessories Recirculating Kit, ZRM-E36AS Recirculating Kit, ZRM-E42AS 5HSODFHPHQW &KDUFRDO )LOWHU HDFK Duct Cover Extension Kit ZRC-0150 ZRC-0151 = ) & Z1C-00RM To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
STAPLE YOUR RECEIPT HERE Proof of the original purchase date is needed to obtain service under warranty Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Two Year Limited Warranty fo