Use, Care, and Installation Guide www.zephyronline.com Siena ZSI-E30BS ZSI-E36BS Model number: Serial Number: JAN17.0101 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... +RRG 6SHFL¿FDWLRQV ................................................... Mounting the Range Hood ...................................... Ductless Recirculating .............................................. 5 6 7 8 9 10 FEATURES & CONTROLS ICON Touch Controls ......................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer. b.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight Equivalent number length x used = Total 3-1/ 4” x 10” 5 Ft. Rect. to 6” round transition x( ) = Ft. 3-1/ 4” x 10” 20 Ft. Rect. to 6” round transition 90 0 elbow x( ) = Ft. 6” round to 1 Ft. 3-1/ 4” x 10” rect. transition x( ) = Ft. Ft. x( ) = Ft. 24 Ft. x( ) = Ft.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. A n. mi . B n mi . C x ma D n. mi . E n mi . F x ma Minimum mount height between range top to hood bottom should be no less than 26”. in. ” m x.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only.
Front of Hood Side of Hood 10 1/2” 8 7/16” STANDARD min. ducted - 27 1/2” min. recirc. - 32” max. - 42” Z1C-00SI min. ducted - 46 1/2” min. recirc. - 50 1/2” max. - 79” 1 9/16” 12 3/8” 29 15/16”, 35 7/8” 21 15/16” Top of Hood 4 1/4” /4” 73 C/L 8 4 3/8” AC In 5/8” Installation – +RRG 6SHFL¿FDWLRQV www.zephyronline.
Installation – Mounting the Hood ! CAUTION: At least two installers are required due to the weight and size of the hood. 1. Measure from range top to hood bottom and mark line A. ´ PLQLPXP IURP UDQJH WRS C/L Duct Cover Bracket 2. Plum and mark center line. 0DUN PRXQWLQJ KHLJKW OLQH % ´ IURP OLQH $ 0DUN PRXQWLQJ KHLJKW OLQH & ´ IURP OLQH $ 9-7/16" 5.
Installation – Ductless Recirculating www.zephyronline.com Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust IURP FRRNLQJ DUH GUDZQ DQG ¿OWHUHG E\ D VHW RI RSWLRQDO FKDUFRDO ¿OWHUV 7KH DLU LV WKHQ SXUL¿HG DQG UH circulated back within the home.
Adjust 5 Speed Levels Lights On/Dim/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.
Features & Controls - ICON Touch Controls www.zephyronline.com 3 LIGHTS BUTTON - Lights are two levels, High and Low. - From off, press one time for High. Press again for Low. Press again to power lights off. 4 DISPLAY INDICATORS Mesh Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the mesh filters. - To reset: With hood off: hold the button for three seconds.
Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain. Do not use any product containing chlorine bleach.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR SIENA WALL Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly. 2. Check the power connection with the unit is connected properly. 3. The wires on the control board are loose. 3. Make sure the wires on the control board are connected properly.
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. $&7 HQDEOHV WKH LQVWDOOHU WR HDVLO\ VHW WKH PD[LPXP EORZHU VSHHG WR RQH RI WZR PRVW FRPPRQO\ VSHFL¿HG &)0 OHYHOV RU &)0 7KH XVDJH RI $&7 PD\ QRW EH QHFHVVDU\ IRU \RXU LQVWDOODWLRQ 3OHDVH FKHFN \RXU ORFDO codes for CFM restrictions. By default the maximum blower CFM is set to 600.
Fan Curve Diagrams www.zephyronline.
17 Fan Curve Diagrams
ZSI-E30BS, ZSI-E36BS VOLTS HZ MAX AMPS 120 60 4 5A 250VAC CIRCUIT DIAGRAM AC 120V Wiring Diagram www.zephyronline.com TLO RD ZSA -E30DS-P R E MAR K S :C ONDE NS E R 11+11uF 250VAC AC 120V 60Hz 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW &)0 EORZHU FRQ¿JXUDWLRQ ACT 390 CFM - Fan Max. 393W @ 3.3A ACT 290 CFM - Fan Max. 365W @ 3.
Limited Warranty TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: 1-888-880-8368 Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows: Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide,
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. 20 | Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Siena ZSI-E30BS ZSI-E36BS Model number: Serial Number: JAN17.0101 © Zephyr Ventilation LLC.
www.zephyronline.
2-3 4 INSTALLATION Feuille de calcul pour le conduit............................................................................... Espace libre et hauteur de montage........................................................................... Options d’installation pour le conduit................................................................................... 6SpFL¿FDWLRQV GH OD KRWWH ......................... Montage de la hotte..............
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
Liste du matériel www.zephyronline.
= Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit ) = pi x( ) = pi x( ) = pi x( ) = pi x( ) = pi 23 pi 7” circ. à rect. de 3-1/4" x 10", coude à 90º x( ) = pi 3-1/ 4” x 10” 30 pi embout mural rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com Lorsqu’il possible de le faire, diminuez TOUJOURS le nombre de pièces et de changements de direction. Si un long tronçon de conduit est nécessaire, augmentez le diamètre du conduit de 8” à 10”. A n. mi . B n i m .C x ma D n. mi . E n i m .F x ma Si des changements de direction ou des adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de recirculation d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
Devant de la hotte Côté de la hotte 10 1/2” 8 7/16” STANDARD min. avec conduit - 27 1/2” min. avec recirc. d’air - 32” max. - 42” Z1C-00SI min. avec conduit - 46 1/2” min. avec recirc. d’air - 50 1/2” max. - 79” 1 9/16” 12 3/8” 29 15/16”, 35 7/8” 21 15/16” Dessus de la hotte 4 1/4” /4” 73 L/C 8 4 3/8” Entrée élec. 5/8” ,QVWDOODWLRQ ± 6SpFL¿FDWLRQV GH OD KRWWH www.zephyronline.
1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A (min. 26” à partir du dessus de la cuisinière). L/C 2. Marquez la ligne centrale avec exactitude. Support pour le recouvrement du conduit 3. Marquez la ligne de hauteur de montage B (à 1-5/16” de la ligne A). 4. Marquez la ligne de hauteur de montage C (à 13-1/8” de la ligne A). 9-7/16" 5. Marquez la largeur de montage B à partir de la L/C (12-3/4”). 7. Fixez (2) vis M4 x 1-1/2” aux poutres de la ligne C.
,QVWDOODWLRQ ± 5HFLUFXODWLRQ G¶DLU VDQV FRQGXLW www.zephyronline.com /D FRQ¿JXUDWLRQ GH UHSULVH VDQV FRQGXLW D pWp FRQoXH SRXU OHV DSSOLFDWLRQV R LO HVW LPSRVVLEOH G¶LQVWDOOHU XQ FRQGXLW d’aération.
Choix de 5 vitesses Lumières : Allumer/Veilleuse/Éteindre Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
&RPPDQGHV ± ,&21 &RPPDQGHV j HIÀHXUHPHQW www.zephyronline.com 3 TOUCHE DE CONTRÔLE DES LUMIÈRES - Il existe deux intensités : haute et basse. - Lorsque les lumières sont éteintes, appuyez une fois pour les allumer à haute intensité. Appuyez de nouveau pour les mettre en veilleuse. Appuyez encore une fois pour les éteindre.
Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide. Après le nettoyage, vous pouvez polir les surfaces avec des produits de polissage à acier inoxydable non abrasifs pour redonner de l’éclat et du lustre aux surfaces.
'pSDQQDJH www.zephyronline.com 352&e'85(6 '( 'e3$11$*( 3285 /$ +277( 6,(1$ :$// 3UREOqPH Cause 6ROXWLRQ Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés 9pUL¿H] TXH OH EUDQFKHPHQW GH O¶DSSDUHLO D pWp IDLW correctement Les lumières fonctionnent, mais le ventilateur ne tourne pas. L’appareil vibre.
Certains codes et règlements limitent la quantité maximale de pi3/min qu’une hotte peut extraire. La ACT permet de contrôler la quantité maximale de pi3/min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux. La ACT permet à l’installateur d’ajuster facilement la vitesse maximale du ventilateur à l’un des niveaux de pi3/min les plus fréquemment utilisés : 390 pi3/min ou 290 pi3/min.
Diagrammes des courbes caractéristiques des ventilateurs www.zephyronline.
17 Diagrammes des courbes caractéristiques des ventilateurs
ZSI-E30BS, ZSI-E36BS VOLTS HZ MAX AMPS 120 60 4 Schema de circuits ROUGE JAUNE GRIS BRUN BLEU AC 120V BLANC CORPS JAUNE JAUNE GRIS BLEU BRUN 5A 250VAC BLANC NOIR VERTE CORPS ROUGE BLANC VERTE NOIR 6FKpPD GH FkEODJH www.zephyronline.com JAUNE TLO RD ZSA -E30DS-P R E MAR K S :C ONDE NS E R 11+11uF 250VAC AC 120V 60Hz &RQVRPPDWLRQ pQHUJpWLTXH DYHF FRQ¿JXUDWLRQ SDU GpIDXW G¶XQ YHQWLODWHXU GH SL3/min. ACT 390 pi3/min - Max. du ventilateur : 393W à 3,3 A ACT 290 pi3/min - Max.
Une preuve de la date d’achat originale est nécessaire pour obtenir du service lorsque le produit est sous garantie Garantie limitée POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de
www.zephyronline.com ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.