Use, Care, and Installation Guide www.zephyronline.com Siena Pro Island ZSL-E42BS ZSL-E48BS Model number: Serial Number: APR19.0201 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... +RRG 6SHFL¿FDWLRQV ................................................... Mounting the Hood ..................................................... 5 6 7 8 9-10 FEATURES & CONTROLS ICON Touch Controls ..................................... 11 MAINTENANCE .............................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. Not for use over an outdoor grill. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow x( ) = Ft. ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 45 0 elbow 3-1/ 4” x 10” Rect. 90 0 flat elbow 15 Ft. 9 Ft. 24 Ft. x( x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft. Round, 90 0 elbow x( 6”, 7”, 8”, 10” 9 Ft. Round, 45 0 elbow x( Total 3-1/ 4” x 10” 5 Ft. Rect.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 10” to 12”. If turns or transitions are required: Install as far away from duct opening and as far apart between the two transitions as possible. Minimum mount height between range top to hood bottom should be no less than 26”. A n. mi . B x ma C n. mi . D x ma Maximum mount height should be no higher than 34”. in.
1(9(5 H[KDXVW DLU RU WHUPLQDWH GXFW ZRUN LQWR VSDFHV EHWZHHQ ZDOOV FUDZO VSDFHV FHLOLQJ DWWLFV RU JDUDJHV All exhaust must be ducted to the outside, unless using the recirculating option. 8VH VLQJOH ZDOO ULJLG PHWDO GXFWZRUN RQO\ )DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL¿HG 6LOYHU 7DSH RU 'XFW 7DSH Some Ducting Options Roof Pitch w/ Flashing & Cap side wall cap w/ gravity damper Soffit or crawl space 7 Installation – Ducting Options WARNING FIRE HAZARD
Installation – +RRG 6SHFL¿FDWLRQ www.zephyronline.com 11 15/16” 15 11/16” STANDARD min. - 32 1/2” max. - 48 1/2” Z1C-01SL min. - 49” max.
Bottom Support Frame Top Support Frame (secures to top of blower housing) back Key Holes Ceiling Joists Front Sid 1 Wood Blocking e 2 Top Support Frame front - facing controls FIG. C 3 Support Frame Arm FIG. B Junction Box FRONT Bottom Support Frame B 4 Mounting Screws (pre-installed) Hood Body Cut-Out Shaded Area FIG. A A FIG. G 'HWHUPLQH PRXQWLQJ ORFDWLRQ RQ FHLOLQJ DQG WHPSRUDULO\ WDSH SDSHU WHPSODWH LQFOXGHG ZLWK WKH KRRG WR the ceiling.
Installation – Mounting the Hood www.zephyronline.com 1 Top Support Frame Top Duct Covers Bottom Duct Covers Bottom Support Frame FIG. D FIG. E ! WARNING: Electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards. This range hood must be properly grounded. Turn off electrical power at service entrance before wiring. FIG. F $WWDFK MXQFWLRQ ER[ WR ORZHU VXSSRUW IUDPH ODWHUDO EUDFNHW E\ 0 [ PP VFUHZV ),* ( 6HFXUH MXQFWLRQ ER[ ZLUH IUR
Adjust 5 Speed Levels Lights On/Dim/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function - Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.
Maintenance www.zephyronline.com SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel &OHDQ SHULRGLFDOO\ ZLWK ZDUP VRDS\ ZDWHU DQG FOHDQ FRWWRQ FORWK RU PLFUR ¿EHU FORWK $OZD\V UXE LQ WKH direction of the stainless steel grain.
Maintenance – Lights LED LIGHT STRIPS ,Q WKH XQOLNHO\ HYHQW WKDW \RXU /(' VWULS IDLOV SOHDVH FRQWDFW =HSK\U WR RUGHU UHSODFHPHQW SDUWV See list of parts and accessories page for part #’s and contact information. To replace LED light strip 5HPRYH DOXPLQXP PHVK ¿OWHUV 2. Remove light panel by two screws. 'LVFRQQHFW /(' OLJKW VWULS TXLFN FRQQHFWRU 4. Push in the two side clips on the ends of the LED strip. 5. Push LED light strip through the light panel opening.
ACT Conversion www.zephyronline.com ALUÀRZ &RQWURO 7HFKQRORJ\ $&7 Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the PD[LPXP EORZHU &)0 RI VHOHFW =HSK\U 9HQWLODWLRQ UDQJH KRRGV ZLWKRXW WKH QHHG IRU H[SHQVLYH PDNH XS DLU NLWV $&7 HQDEOHV WKH LQVWDOOHU WR HDVLO\ VHW WKH PD[LPXP EORZHU VSHHG WR RQH RI WZR PRVW FRPPRQO\ VSHFL¿HG &)0 OHYHOV RU &)0 7KH XVDJH RI $&7 PD\ QRW EH QHFHVVDU\ IRU \RXU LQVWDOODWLRQ 3OHDVH FKHFN \RXU ORFDO codes for CFM
Fan Curve Diagrams Pressure (inAq) Blower Fan Curve Model: ZSL AC Input: 120V, 60Hz Outlet Diameter: 10in 2.80 2.70 2.60 2.50 2.40 2.30 2.20 2.10 2.00 1.90 1.80 1.70 1.60 1.50 1.40 1.30 1.20 1.10 1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.
Fan Curve Diagrams www.zephyronline.
AC N AC L RED HI MID LO TR ANS F OR ME R R E MAR K S :C ONDE NS E R 11+11uF 250VAC 2 F IT AC 120V 60Hz 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW &)0 EORZHU FRQ¿JXUDWLRQ ACT 590 CFM - Fan Max. 556W @ 4.6A ACT 390 CFM - Fan Max. 381W @ 3.
Troubleshooting www.zephyronline.com TROUBLESHOOTING PROCEDURES FOR SIENA PRO ISLAND Issue Cause What to do After installation, the unit doesn’t ZRUN 1. The power source is not turned ON. 0DNH VXUH WKH FLUFXLW EUHDNHU DQG WKH XQLW¶V power is ON. 7KH SRZHU OLQH DQG WKH FDEOH ORFNLQJ FRQQHFWRU is not connecting properly. &KHFN WKH SRZHU FRQQHFWLRQ ZLWK WKH XQLW LV connected properly. 3. The wires on the control board are loose.
PART# Replacement Parts %DႉH )LOWHU HDFK LED Light Strip, 9W Z0B0042 Optional Accessories Extension Duct Cover 8QLYHUVDO 0DNH 8S $LU 'DPSHU Z1C-01SL 08$ $ To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
Warranty www.zephyronline.
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 21 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Siena Pro Island ZSL-E42BS ZSL-E48BS Numéro de modèle : _________________ Numéro de série : _________________ APR19.0201 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Feuille de calcul pour le conduit ........................... Espace libre et hauteur de montage ................... Options d’installation pour le conduit .................. 6SpFL¿FDWLRQV GH OD KRWWH......................................... Montage de la hotte ................................................... 5 6 7 8 9-10 COMMANDES &RPPDQGHV j HႉHXUHPHQW .................................. 11 ENTRETIEN ....................................................................................
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage. Cet appareil n’est pas conçu pour être utilisé au-dessus d’un gril extérieur.
Liste du matériel www.zephyronline.
= 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º x( ) = pi 3-1/ 4” x 10” rect., droit 3-1/ 4” x 10” rect., coude à 45º 3-1/ 4” x 10” rect., coude plat à 90º 7” to 6” or 8” to 7” circ. reducteur conique 15 pi 9 pi 24 pi 25 pi x( x( x( 15 pi 6”, 7“, 8” circ. bouchone de l’air x( 6”, 7”, 8”, 10” 15 pi circ.
Installation – Espace libre et hauteur de montage www.zephyronline.com La hauteur de montage minimale ne devrait pas être moins de 26”. La hauteur de montage maximale ne devrait pas outrepasser 34”. Il est important d’installer la hotte à la hauteur de montage adéquate.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
15 11/16” 11 15/16” STANDARD min. - 32 1/2” max. - 48 1/2” Z1C-01SL min. - 49” max. - 81” 20 7/8” 6” 1 9/16” 11 3/8” 41 7/8” , 47 7/8” 28” CÔTÉ DEVANT 13 1/16” 6 3/4” 5/8” C/L O 9 15/16” C/L C/L 12 5/8” 6 5/8” 9 15/16” C/L 13/16” Installation – 6SpFL¿FDWLRQV GH OD KRWWH www.zephyronline.
Top Support Frame Cadre de fixation inférieur (est fixé à la partie supérieure du boîtier du ventilateur) Dos Encoches en trou Solives de plafond Front Sid 1 Bloc de bois e 2 Cadre de fixation supérieur Devant – commandes à l’avant FIG. C 3 Bras du cadre de fixation FIG. B Boîte de jonction Devant Cadre de fixation inférieur B 4 Vis de montage (préinstallées) Boîtier de la hotte Zone de découpage ombragée FIG.
Installation – 0RQWDJH GH OD KRWWH www.zephyronline.com 1 Cadre de fixation supérieur Pièces de recouvrement supérieures Pièces de recouvrement inférieures Cadre de fixation inférieur FIG. E FIG. D ! AVERTISSEMENT : Le câblage électrique doit être effectué par une ou des personnes qualifiées selon les stipulations de tous les normes et standards en vigueur. Éteignez l’alimentation électrique à l’entrée de service avant de procéder au câblage. FIG.
Choix de 5 vitesses Lumières : Allumer/Veilleuse/Éteindre Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
Entretien - 1HWWR\DJH GH OD KRWWH HW GHV ¿OWUHV ENTRETIEN DES SURFACES: 1HWWR\H] UpJXOLqUHPHQW OHV VXUIDFHV GH OD KRWWH DYHF GH O¶HDX VDYRQQHXVH FKDXGH HW XQ FKLႇRQ GH FRWRQ SURSUH 1¶XWLOLVH] pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
Dans l’éventualité peu probable d’une défaillance de votre bande de LED, veuillez contacter Zephyr pour commander des pièces de rechange. Voir la liste des pièces et accessoires à la page pour les références et les coordonnées. Pour remplacer la bande lumineuse à LED 5HWLUH] OHV ¿OWUHV j PDLOOHV HQ DOXPLQLXP 2. Retirez le panneau d’éclairage à l’aide de deux vis. 3. Débranchez le connecteur rapide du bandeau lumineux à LED. 4. Appuyez sur les deux clips latéraux situés aux extrémités de la bande de LED.
Conversion de la ACT www.zephyronline.com 7HFKQRORJLH GH FRQWU{OH GX GpELW G¶DLU $&7 Certains codes et règlements limitent la quantité maximale de pi3/min qu’une hotte peut extraire. La ACT permet de contrôler la quantité maximale de pi3/min qu’évacuent un éventail de hottes Zephyr, éliminant la nécessité d’acheter un dispositif d’air d’appoint dispendieux.
Tableau De Rendement ZSL 15
Tableau De Rendement www.zephyronline.
GRIS BRUN BLEU JAUNE ROUGE VERTE CORPS MOT O R ROUGE ROUGE ZSL-E42BS ZSL-E48BS Tension : 120V 60Hz Modèle : BLANC GRIS BRUN BLEU JAUNE ROUGE VERTE CORPS MO TO R JAUNE JAUNE JAUNE JAUNE BRUN GRIS BLEU F US E C OM BLANC AC N AC L HI MID LO TR ANS F OR ME R C ONTR OL P C PROTÉGÉ THERMIQUEMENT CORPS VERTE NOIR Total: Max.818W 7A Lampe : Max.
Dépannage www.zephyronline.com PROCÉDURES DE DÉPANNAGE POUR LA HOTTE SIENA PRO Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés 9pUL¿H] TXH OH EUDQFKHPHQW GH O¶DSSDUHLO D pWp IDLW correctement Les lumières fonctionnent, mais le ventilateur ne tourne pas. L’appareil vibre.
NO DE PIÈCE Pièces de remplacement )LOWUH j GHÀHFWXHU FKDTXH Bandes de lumière LED Z0B0042 Accessoires optionnels Ensemble de prolongement de recouvrement de conduit Universal maquillage volet d’air Z1C-01SL MUA010A Pour commander des pièces, visitez-nous en ligne au www.zephyronline.
Garantie www.zephyronline.
ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits.