Use, Care, and Installation Guide www.zephyronline.com Venezia ZVE-E30CS ZVE-E36CS ZVE-E42CS Model number: Serial Number: APR19.0401 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Ducting Calculation Sheet ....................................... Mounting Height & Clearance................................ Ducting Options ........................................................... +RRG 6SHFL¿FDWLRQV ................................................... Mounting the Range Hood ...................................... Ductless Recirculating .............................................. 5 6 7 8 9 10 FEATURES & CONTROLS Touch Controls ...........................................
www.zephyronline.com Important Safety Notice READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a. Use this unit only in the manner intended by the manufacturer, if you have questions, contact the manufacturer.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION 7R UHGXFH ULVN RI ¿UH DQG WR SURSHUO\ H[KDXVW DLU RXWVLGH 'R QRW YHQW H[KDXVW DLU LQWR VSDFHV ZLWKLQ ZDOOV FHLOLQJV attics, crawl spaces or garages. OPERATION $OZD\V OHDYH VDIHW\ JULOOHV DQG ¿OWHUV LQ SODFH :LWKRXW WKHVH FRPSRQHQWV RSHUDWLQJ EORZHUV FRXOG FDWFK RQWR KDLU ¿QJHUV and loose clothing.
List of Materials www.zephyronline.
Duct pieces Total 1 Ft. x( ) = Ft. 6”, 7”, 8”, 10” 1 Ft. Round, straight x( ) = Ft. 3-1/ 4” x 10” Rect. 90 0 elbow 15 Ft. x( ) = Ft. 3-1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x( ) = 3-1/ 4” x 10” Rect., straight 3-1/ 4” x 10” Rect. 90 0 flat elbow 24 Ft. x( 7” to 6” or 25 Ft. 8” to 7” Round tapered reducer x( 15 Ft. x( 6”, 7“, 8” Round in-line damper 6”, 7”, 8”, 10” 15 Ft. Round, 90 0 elbow x( 6”, 7”, 8”, 10” 9 Ft. Round, 45 0 elbow x( Total 3-1/ 4” x 10” 5 Ft. Rect.
Installation – Mounting Height & Clearance www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. A n. mi . B n i m .C x ma D n. mi . E n mi . F x ma Minimum mount height between range top to hood bottom should be no less than 26”. in. ” m x.
1(9(5 H[KDXVW DLU RU WHUPLQDWH GXFW ZRUN LQWR VSDFHV EHWZHHQ ZDOOV FUDZO VSDFHV FHLOLQJ DWWLFV RU JDUDJHV All exhaust must be ducted to the outside, unless using the recirculating option. 8VH VLQJOH ZDOO ULJLG 0HWDO GXFWZRUN RQO\ )DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL¿HG 6LOYHU 7DSH RU 'XFW 7DSH Some Ducting Options Roof Pitch w/ Flashing & Cap side wall cap w/ gravity damper Soffit or crawl space side wall cap w/ gravity damper ductless recirculating 7 Inst
Front of Hood Side of Hood 14 5/16” 10 9/16” Z1C-01VE min. ducted - 45” min. recirc. - 49 1/2” max. - 80” 1 9/16” 10 1/4” 6 7/16” STANDARD min. ducted - 27” min. recirc. - 31 1/2” max. - 44” 29 15/16”, 35 7/8”, 41 7/8” 24” 5 1/4” 4 9/16” Top of Hood 5 3/16” Installation – +RRG 6SHFL¿FDWLRQV www.zephyronline.
0HDVXUH IURP UDQJH WRS WR KRRG ERWWRP DQG PDUN OLQH $ ´ PLQLPXP IURP UDQJH WRS C/L Duct Cover Bracket 3OXP DQG PDUN FHQWHU OLQH 0DUN PRXQWLQJ KHLJKW OLQH % ´ IURP OLQH $ 3-9/16" 0DUN PRXQWLQJ VSUHDG IURP & / RQ OLQH % )URP FHQWHU OLQH WR OHIW PRXQW PDUN ´ )URP FHQWHU OLQH WR ULJKW PRXQW PDUN ´ )DVWHQ 0 [ ´ VFUHZV LQWR VWXGV RQ OLQH % 'R QRW fasten screws all the way.
Installation – Ductless Recirculating www.zephyronline.com 'XFWOHVV UHFLUFXODWLQJ LV LQWHQGHG IRU DSSOLFDWLRQV ZKHUH DQ H[KDXVW GXFW ZRUN LV QRW SRVVLEOH WR EH LQVWDOOHG When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust IURP FRRNLQJ DUH GUDZQ DQG ¿OWHUHG E\ D VHW RI RSWLRQDO FKDUFRDO ¿OWHUV 7KH DLU LV WKHQ SXUL¿HG DQG UH FLUFXODWHG EDFN ZLWKLQ WKH KRPH We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new
Display (speed level, delay off, filter clean/change,clean air) clean mesh filter clean air replace charcoal filter Adjust 6 Speed Levels Lights On/Dim/Off 1 Power / Delay Off Button Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights. Press Button again and the hood will turn back on at speed 4 and high lights level.
Features & Controls – User Interface www.zephyronline.com Mesh Filter Clean Indicator (always enabled) - After 30 hours of fan usage the Graphic and words “clean mesh filter” will illuminate indicating it is time to clean the mesh filters. Graphic and words will remain illuminated until reset. - To reset: With hood off, hold the Button for three seconds, after three seconds the Graphic and words “clean mesh filter” will turn off and the 30 hour timer will reset.
Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel &OHDQ SHULRGLFDOO\ ZLWK ZDUP VRDS\ ZDWHU DQG FOHDQ FRWWRQ FORWK RU PLFUR ¿EHU FORWK $OZD\V UXE LQ WKH direction of the stainless steel grain. To remove heavier grease build up use a liquid degreaser detergent.
Maintenance – Lights www.zephyronline.com BLOOM HD LED LIGHTS ,Q WKH XQOLNHO\ HYHQW WKDW \RXU %ORRP /(' OLJKW IDLOV SOHDVH FRQWDFW =HSK\U WR RUGHU UHSODFHPHQW SDUWV 6HH OLVW RI SDUWV DQG DFFHVVRULHV SDJH IRU SDUW ¶V DQG FRQWDFW LQIRUPDWLRQ To replace Bloom LED light 5HPRYH EDႉH ¿OWHUV 2. Remove light panel by two screws. 'LVFRQQHFW %ORRP /(' OLJKW TXLFN FRQQHFWRU 4. Remove two screws from each side of Bloom LED 5. Push Bloom LED light through the light panel opening.
Issue Cause What to do After installation, the unit doesn’t ZRUN 1. The power source is not turned ON. 0DNH VXUH WKH FLUFXLW EUHDNHU DQG WKH XQLW¶V power is ON. 7KH SRZHU OLQH DQG WKH FDEOH ORFNLQJ FRQQHFWRU is not connecting properly. &KHFN WKH SRZHU FRQQHFWLRQ ZLWK WKH XQLW LV connected properly. 3. The wires on the control board are loose. 0DNH VXUH WKH ZLUHV RQ WKH FRQWURO ERDUG DUH connected properly. 4. The switch board and control board wirings are disconnected.
ACT Conversion www.zephyronline.com WHY CONTROL THE MAXIMUM BLOWER CFM? Zephyr recommends to always use the appropriate blower CFM to handle your cooking surface but some local codes limit the maximum amount of CFM a range hood can move. Zephyr Airflow Control Technology (ACT) allows you to control the maximum blower CFM of hoods with Zephyr’s DCBL Suppression System. ACT enables the installer to easily set the maximum blower speed to one of three most commonly specified CFM levels; 590, 390 or 290 CFM.
17 Fan Curve Diagrams
Fan Curve Diagrams www.zephyronline.
Wiring Diagram Model: ZVE-E30CS ZVE-E36CS ZVE-E42CS Voltage: 120V 60Hz Power consumption Total: Max. 215W @ 4.0A Lamp: Max. 6Wx2 Fan: Max. 203W Electronically Protected U V W U V W 5A 250V AC-N ON/OFF DOWN UP AC-L LAMP 3RZHU FRQVXPSWLRQ VKRZQ IRU GHIDXOW &)0 EORZHU FRQ¿JXUDWLRQ ACT 590 CFM - Fan Max. 130W @ 1.8A ACT 390 CFM - Fan Max. 70W @ 1A ACT 290 CFM - Fan Max. 35W @ .
List of Parts and Accessories www.zephyronline.com DESCRIPTION PART# Replacement Parts %DႉH )LOWHU HDFK /(' : /LJKW EXOE HDFK = % Optional Accessories Recirculating Kit ZRC-02VE 5HSODFHPHQW &KDUFRDO )LOWHU HDFK = ) & Duct Cover Extension Kit Z1C-01VE Remote Control Kit RC-0001 0DNH 8S $LU 'DPSHU .LW 08$ $ To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.
Three Year Limited Warranty for Parts: For three years from the date of your original purchase of the Products, we will provide, free of charge, Products or parWV LQFOXGLQJ /(' OLJKW EXOEV LI DSSOLFDEOH WR UHSODFH WKRVH WKDW IDLOHG GXH WR manufacturing defects subject to the exclusions and limitations below. We may choose, in our sole discretion, to repair or replace parts before we elect to replace the Products.
www.zephyronline.com PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes. Notification of product changes or recalls. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.
Guide d’utilisation, d’entretien et d’installation www.zephyronline.com Venezia ZVE-E30CS ZVE-E36CS ZVE-E42CS Numéro de modèle : _________________ Numéro de série : _________________ APR19.0401 © Zephyr Ventilation LLC.
www.zephyronline.
INSTALLATION Feuille de calcul pour le conduit ........................... Espace libre et hauteur de montage ................... Options d’installation pour le conduit .................. 6SpFL¿FDWLRQV GH OD KRWWH......................................... Montage de la hotte ................................................... Reprise d’air sans conduit ....................................... 5 6 7 8 9 10 COMMANDES &RPPDQGHV j HႉHXUHPHQW .................................. 11 Interface utilisateur .........
www.zephyronline.com Mise en garde de sécurité LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a. N’utilisez cet appareil que de la manière prévue par le fabricant. Si vous avez des questions, communiquez avec le fabricant. b.
POUR RÉDUIRE LES RISQUES D’INCENDIE, N’UTILISEZ QUE DES CONDUITS D’AÉRATION EN MÉTAL. ATTENTION Pour réduire les risques d’incendie et pour évacuer l’air convenablement, assurez-vous de canaliser l’air à l’extérieur de la maison. N’installez pas l’échappement du conduit dans les espaces entre les murs, le plafond, le grenier, les vides sanitaires ou le garage.
Liste du matériel www.zephyronline.
= Longueur x Nombre utilisé Pièces de conduit Total 1 pi x( ) = pi 6”, 7”, 8”, 10” 1 pi circ., droit x( ) = pi 3-1/ 4” x 10” rect., coude à 90º 15 pi x( ) = pi 3-1/ 4” x 10” rect., coude à 45º 9 pi x( ) = pi 6” circ. à rect. de 3-1/4" x 10" 3-1/ 4” x 10” rect., droit x( ) = pi x( ) = pi x( ) = pi x( ) = pi x( ) = pi 23 pi 7” circ. à rect. de 3-1/4" x 10", coude à 90º x( ) = pi 3-1/ 4” x 10” 30 pi embout mural rect.
Installation – Espace libre et hauteur de montage www.zephyronline.com adaptateurs sont nécessaires, installez-les le plus loin possible de l’ouverture et le plus éloigné possible l’un de l’autre. La hauteur de montage minimale ne devrait pas être moins de 26”. A n. mi . B n mi . C x ma D n. mi . E n i m .F x ma La hauteur de montage maximale ne devrait pas outrepasser 34”. Il est important d’installer la hotte à la hauteur de montage adéquate.
N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de reprise d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
Devant de la hotte Côté de la hotte 14 5/16” 10 9/16” Z1C-01VE Min. avec conduit - 45” Min. avec reprise d’air - 49 1/2” max. - 80” 1 9/16” 10 1/4” 6 7/16” STANDARD Min. avec conduit - 27” Min. avec reprise d’air - 31 1/2” max. - 44” 29 15/16”, 35 7/8”, 41 7/8” 24” 5 1/4” 4 9/16” Dessus de la hotte 5 3/16” Installation – 6SpFL¿FDWLRQV GH OD KRWWH www.zephyronline.
L/C 1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A (min. 26” à partir du dessus de la cuisinière). Support pour le recouvrement du conduit 2. Marquez la ligne centrale avec exactitude. 3. Marquez la ligne de hauteur de montage B (à 10-1/4” de la ligne A). 3-9/16" 4. Marquez la largeur de montage à partir de la L/C. De la ligne de centre pour la marque de mont (3-9/16”). Da la ligne de centre pout redresser la marque de mont (4-3/4”) 5.
Installation – Reprise d’air sans conduit www.zephyronline.com /D FRQ¿JXUDWLRQ GH UHSULVH VDQV FRQGXLW D pWp FRQoXH SRXU OHV DSSOLFDWLRQV R LO HVW LPSRVVLEOH G¶LQVWDOOHU XQ FRQGXLW d’aération.
Affichage (vitesse, arrêt automatique, nettoyage/changement des filtres, purification d’air) clean mesh filter clean air replace charcoal filter Choix de six vitesses Lumières : Allumer/Veilleuse/Éteindre 1-Touche de mise en marche/arrêt automatique Fonction de mise en marche - La touche permet d’allumer et d’éteindre la hotte (ventilateur et lumières).
Commandes – Interface utilisateur www.zephyronline.com Indicateur de nettoyage des filtres à tamis (toujours en fonction) - Après 30 heures d’utilisation du ventilateur, le symbole et les mots « clean mesh filter » s’illuminent, indiquant qu’il est temps de nettoyer les filtres à tamis. Le symbole et les mots restent illuminés jusqu’à la réinitialisation de la fonction. - Pour réinitialiser : Lorsque la hotte est éteinte, appuyez et tenez la touche enfoncée pendant trois secondes.
1HWWR\H] UpJXOLqUHPHQW OHV VXUIDFHV GH OD KRWWH DYHF GH O¶HDX VDYRQQHXVH FKDXGH HW XQ FKLႇRQ GH FRWRQ SURSUH N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
Entretien - lumières LED www.zephyronline.com BLOOM LUMIERES LED 'DQV OH FDV SHX SUREDEOH R YRWUH ODPSH j '(/ %ORRP WRPEHUDLW HQ SDQQH FRQWDFWH] =HSK\U SRXU FRPPDQGHU des pièces de rechange. Voir la liste des pièces et accessoires à la page pour les références et les coordonnées. Pour remplacer la lampe à LED Bloom 5HWLUH] OHV ¿OWUHV j PDLOOHV HQ DOXPLQLXP 2. Retirez le panneau d’éclairage à l’aide de deux vis. 3. Débranchez le connecteur rapide du voyant Bloom LED. 4.
Problème Cause Solution Après l’installation, l’appareil ne fonctionne pas. 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur et de l’appareil est allumée 2.
Conversion de la ACT www.zephyronline.com ! ATTENTION : Vous devez débrancher la hotte de l’alimentation principale avant de suivre les instructions de conversion énumérées ci-dessous, sans quoi vous pourriez vous blesser ou endommager l’appareil.
17 Tableau De Rendement Du Ventilateur
Courbe de rendement du ventilateur, 390 CFM Entree en CA: 120V, 60 Hz Diametre du conduit de sortie : 8” Pression (en TQ) Tableau De Rendement Du Ventilateur www.zephyronline.
Total: Max. 215W @ 4.0A Lampe: Max. 6Wx2 Ventilateur: Max. 203W V W U V W 5A 250V AC-N AC-L CCI DES COMMANDES PROTÉGÉ THERMIQUEMENT ON/OFF DOWN &RQVRPPDWLRQ PRQWUp SRXU GpIDXW GH FRQ¿JXUDWLRQ GX YHQWLODWHXU &)0 ACT 590 CFM - Ventilateur Max. 130W @ 1.8A ACT 390 CFM - Ventilateur Max. 70W @ 1A ACT 290 CFM - Ventilateur Max. 35W @ .
Listes des pièces et des accessoires www.zephyronline.com DESCRIPTION NO DE PIÈCE Pièces de remplacement )LOWUH j GHÀHFWHXU FKDTXH Ampoule DEL 6W (chaque) Z0B0034 Accessoires optionnels Ensemble de reprise d’air Filtres à charbon de remplacement (chaque) Ensemble de prolongement de recouvrement de conduit ZRC-02VE Z0F-C091 Z1C-01VE Pour commander des pièces, visitez-nous en ligne au www.zephyronline.
Une preuve de la date d’achat originale est nécessaire pour obtenir du service lorsque le produit est sous garantie Garantie limitée POUR OBTENIR DU SERVICE SOUS GARANTIE OU POUR TOUTE QUESTION LIÉE À L’ENTRETIEN, veuillez communiquer avec nous au 1-888-880-8368 Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de
www.zephyronline.com ENREGISTRMENT DU PRODUIT Nous vous félicitons d’avoir acheté une hotte Zephyr. Veuillez prendre un moment pour enregistrer votre nouvelle hotte au www.zephyronline.com/registration C’EST IMPORTANT Cet enregistrement rapide est utile à bien des égards. Il assure la couverture de votre garantie si vous avez besoin de service après-vente. À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire.