Specifications
57
SCRrimmer Stik
Power the Loads
Connect any incandescent or quartz load into each of the outlets. The power-handling SCR
components can withstand up to four times the current rated capacity. Overload conditions
are protected at the outlets to avoid common failures.
Test the Load without a Signal
With the load connected, press the test button. The load will be powered to full. The test
button allows for simple load or focus checks. Press the button again and the load will fade
out. Otherwise, the test switch will automatically switch off after a seven and one half-
minute period.
Create the Look
With the DMX Controller on line, the SCRimmer Stik™ is ready to respond to the commands
of the signal generator. The lamp output is smooth and even, without flickering or stepping.
It’s Serviceable
The SCRimmer Stik™ offers the best value in the market by making the critical compo-
nents of the unit user serviceable. The plug-in SCR control for each dimmed outlet can be
replaced with a screwdriver. The lightweight design and unique mounting hardware make
the SCRimmer Stik™ fit into any environment.
100V n 220 - 240V NON CE n
110 - 127V
n 277V n
230V CE
n 347V n
StandardsVoltage
3
3
3
3
This product conforms to one or more of the above standards. Please contact your local Cooper Controls representative for further information.
Dimensions
EDI SCRimmer Stick
2.5"(H) x 36"(W) x 1.75"(D)
(64mm x 914mm x 45mm)
Weight: 8.5lb / 3.9Kg
Electrical Characteristics
Input Power
120/240 VAC Changeable Automatic
50/60Hz Detection
Operating Environment
Temperature range: 32°F. (0°C) to 104°F.
(40°C).
Humidity: 0% - 90% Non-condensing
Signal Protocol
USITT DMX-512 (1990)
Indicator: LED (amber)
DMX loss/Auto Hold: 7.5 minutes
Dimmers
Switch type: Plug-in SCR Solid State Relay
Capacity: 4 x 600 Watts or 2 x 1200 Watts
(2400 watts total)
Rise Time: 250μs 10-90%
Load Types
Incandescent or Quartz Lamps
Magnetic Transformer Low Voltage
Dimmable Electronic Transformer,
Low Voltage*
*Designed for dimmable electronic low-
voltage fixtures. Consult factory for additional
compatibility information.
Isolation Voltage
2500V
Surge Current
250 Amp Peak, 1 cycle
Output Circuit Protection
Two 10 Amp or Four 6.5Amp 3AG Ceramic
Fuses
Input Lead
12/3 SO Cord, 36"
Catalog#
Prepared by
Project
Date