Specifications

59
Dimensions
EDI Big Stik
4.8"(H) x 78"(W) x 3.5"(D)
(122mm x 1981mm(W) x 89mm)
Weight: 41.0lb / 18.6Kg (3 x 2.4kW version)
46.0lb / 21.9Kg (6 x 1.2kW version)
Electrical Characteristics
Power Requirements
120/208 VAC, 3 Ø automatic 50/60Hz
detection operating
Environment
Temperature range: 32°F.(0°C) to 104°F.
(40°C).
Humidity: 0% - 90% Non-condensing
Dimmer Capacity
6 x 1.2kW or 3 x 2.4kW
Load Types*
Incandescent, quartz lamps, and electronic
low voltage fixtures.
* Designed for dimmable electronic low voltage
fixtures. Consult factory for additional compat-
ibility information.
Rise Time
325μs 10-90%
EDI Big Stik
100V n 220 - 240V NON CE n
110 - 127V
n 277V n
230V CE
n 347V n
StandardsVoltage
3
3
3
3
This product conforms to one or more of the above standards. Please contact your local Cooper Controls representative for further information.
Specifications
n
The Big STIK shall be designed to dim standard quartz, incandescent, and electronic low
voltage sources.
n
The enclosure shall accommodate 6 x 1.2 kW or 3 x 2.4 kW dimmers.
n
The Big STIK dimmer shall be convection cooled. Each dimmer module will include a
thermal sensor that will shut down the dimmer if the heatsink temperature exceeds 185° F
(85° C).
n
The dimmers shall use an encapsulated pair of silicon controlled rectifiers to provide
symmetrical AC output to the load at any output level from OFF to FULL intensity. The
entire load of the dimmer will be carried solely by the silicon controlled rectifiers. The silicon
controlled rectifier is inherently designed in such a manner that it is impossible for any spuri-
ous voltage to be transferred to the control wires and damage low voltage electronics.
n
Supply Voltage: Single Phase 85-260 Volts via CEE22 connector
n
Each module shall have a toroidal, copper wound, iron core high performance choke.
Performance rise time shall be no less than 325 μs. All measurements shall be from 10% to
90% at full load.
n
The maximum heat loss for each 2.4kW dimmer shall be no greater than 48 watts per dim-
mer or 100 BTU's per hour per connected kW of load.
n
The dimmers shall operate over an input voltage range of 90 to 140 VAC per phase. The
dimming system will operate from a 3 Ø input.
n
Incandescent dimmers shall function properly with any load from 25 watts to rated capacity.
n
The dimmer will be controlled by a standard USITT DMX-512A control signal.
n
The assignable work light function shall be remotely controlled via wired remote on/off
controls.
n
All dimming functions shall be microprocessor controlled with no internal trim
potentiometers or other adjustments.
n
All control electronics shall be incorporated on a single double sided FR4-G10, U.L. Listed,
printed circuit board.
n
The entire assembly is UL Listed.