Instruction manual
Setup 
Page 68      Solution & Solution XL Operating Manual – Issue 1.0 
sACN (ANSI-E1.31) 
Solution & Solution XL can output DMX via the Streaming ACN standard for 
DMX over Ethernet transport.  This standard is approved by ANSI and ESTA 
as the new DMX over Ethernet standard and allows ZerOS to communicate 
with a multitude of sACN enabled devices already out there. 
In Setup, choose the Network tab and then select sACN: 
Figure 55 - sACN Configuration 
Each  DMX  universe  is  offered  as  a  line  item  with  configuration  options  for 
each  universe.   By  default  all universes  are disabled,  so  enable  only  the 
universes you require in order to reduce the network overhead. 
Figure 56 - sACN Universe Configuration
Each  sACN  universe  can  be  either  “Live”  or  “Preview”  output  – the Preview 
output option although configurable is not implemented in ZerOS as of version 
7 software. 
Note : Preview universes are not implemented in ZerOS 7 software. 
sACN allocates a universe number to each DMX universe, which must be set 
the same on the transmitting device (ZerOS console) and the receiving device 
(the  DMX output box,  or fixture, etc).   In addition, each  universe  can be 
defined  a  Priority  level  (0-200)  –  sACN  receptive  devices  will  automatically 
listen for the highest priority number received and respond to that signal.  In 
this way, multiple consoles can be running on a network at the same time and 
can automatically take over from one another – a function used in our tracking 
backup software. 
Each sACN universe can also have a unique name associated with it, which 
can be entered from a USB keyboard.  This functionality allows you to identify 
which universe is coming from which console on a larger networked system. 