If the product is still within warranty then
contact technical support. If the product is no
longer in warranty replace immediately!
IMPORTANT: The selected power pack
was chosen to provide power beyond
the lifetime of the product, in particular the
sensor (under normal operating conditions).
The sensor life is seven years, for this reason,
the detector should be replaced after seven
years from the date of installation.
WARNING: Prolonged exposure to
temperatures outside those stated above
will reduce the power pack and sensor life.
Zeta Technical Support Line
9.00am–5.00pm,Monday–Friday.
Telephone: +44 (0) 1792 445 175
e-mail:support@zetaalarmsystems.com
UNDERSTANDING
THE PRODUCT’S
INDICATORS
The higher the concentration of carbon
monoxide detected by the detector, the
quicker it will respond. When sufcient
carbon monoxide is detected a loud audible
signal(85dBat1m(3feet))willbeemitted
and the Alarm LED will flash red once every
second.
The Alarm will sound:
•Between60and90minuteswhen
exposedtoaminimumof50ppmofCO.
•Between10and40minuteswhen
exposedtoaminimumof100ppmofCO.
•Within3minuteswhenexposedtoa
minimumof300ppmofCO.
Fault / low power pack signal:
Theunitcontinuouslychecksthesettingsofits
sensor and circuitry. If any of these settings
arefoundtobeincorrectorifthepowerpack
becomes low then the detector will emit a
single chirp once per minute and the Fault
LED will flash yellow once per minute for up
to30days.
IMPORTANT: This does NOT mean
that the detector has detected carbon
monoxide.