User manual
16
TECHNICAL INFORMATION
DetectorSpecications: ModelZD-CO-9X
SensorType: Electrochemical
SensorLife: 7Years
AlarmSoundLevel: 85dBat1metre(3feet)
PowerPackLife: 7years(Lifeofproduct)
TemperatureRange: -10ºC(14ºF)to40ºC(104ºF)
OperatingHumidityRange: 30-90%RH
Weight: 90grams(3.2oz)
Certiedto: BSEN50291:2001
WARNING: Prolonged exposure to temperatures and humidity outside those stated
above will reduce the power pack and sensor life.
This Zeta carbon monoxide detector is designed to continuously monitor for CO. Its response
timesmeettherequirementsofBSIstandardBSEN50291:2001.
Thealarmwillsound:
•Between60and90minuteswhenexposedto50ppmofCO.
•Between10and40minuteswhenexposedto100ppmofCO.
•Within3minuteswhenexposedtoCOlevelsof300ppmormore.