Specifications

Managing the Subscriber Database with ZbaseW
112 025-9034AA
Append Time Stamp
Checking this box causes the paging terminal to append a time stamp o the end of the
display message sent to the pager.
Caller Entered Function Code
This field determines whether or not a caller is allowed/required to enter a function code
for the digital pager being paged. The choices are: N (no), A (allowed), or R (required).
The default setting for this parameter is N (no).
Function Code
(1 to4)
Paging, Insure, and Notify all include a Function Code. This selects POCSAG function
code (refer to your pager service manual for how your pager treats functions). You can
allow callers to select the function at the time of call.
For additional information about Golay function codes, see GSC Function Code Table on
page 121.
Group Function Code
(1 to4)
Paging, Insure, and Notify all include a Group Function Code. This is the function code
used when this pager is being called as a member of a group. Thus the pager can alert
differently when it is receiving a group call. If this pager is to be part of a group, fill in 1 to
4.
Announce
An “A” in one of the Modes Allowed fields supports Announcement only service. When
callers access this subscriber, the subscribers customized announcement greeting is
played, and no more action occurs. The subscriber should have “C” marked in the
Welcome field of the Voice Prompt window. Also, the Announce Limit (0 to 255 seconds)
should be set in the Voice Prompt linked window.
Talkback
A “T” in one of the Modes Allowed fields supports Talkback paging. This feature is
described under Talkback Paging on page 165. The parameter Voice Seconds Maximum
shown here sets the maximum length of the conversation.