Specifications
Troubleshooting and Repair Procedures
186 025-9035AA
• If you have had a system for years, and/or it is used in an environment with a 
corrosive atmosphere, you may want to periodically check and clean the contacts in 
the system - the backplane connector contacts and the mating gold fingers on the 
cards; the power supply Molex connector contacts; the RJ2EX connections to the 
phone lines and transmitters; and perhaps even the socketed ICs on the cards.
• Check with us occasionally for new features and capabilities that may be useful to 
you. The best way to do this is to make sure you subscribe to the Zetron Advantage 
newsletter.
Troubleshooting the Office Computer
The office computer environment is the hardest for us to predict and control. Problems 
vary from incompatibility with modems to cables not correct for the application. 
Installation errors are reduced by using special installation programs so the installer need 
not know much about DOS, but problems still can occur. The following table contains 
information on isolating communication problems between the terminal and the office 
computer. 
Symptom Problem Solution
Error “no response...” Comm port contention
Modem not configured for “word 
result codes”
Cable connecting to external 
modem not appropriate
Comm port set wrong in Locations 
database
Be sure the modem is configured 
for unique port number
Check modem manual for DIP 
switch configuration
The cable must pass pins 
2,3,4,5,6,7,8,20 straight through
Edit Locations database
Error “no carrier...” Terminal's modem line not 
working
Terminal not answering
Phone # set wrong in Locations 
database
Verify plugged into modem (slot 
2) wall or line jack Verify line 
with telephone
Verify terminal is operating
Edit Locations database
Computer calls, terminal answers, 
but “no carrier”
Modem not configured for “word 
results codes”
Modem not Hayes compatible 
see above
Use correct modem