Table 32: Station Card OPARAM Codes (continued)
(**) = default value for parameter
Meaning cc pp qq ...
Multitone time call 03 28 byte 1 = zone for time call enable/disable
byte 2 = 00 to disable or 01 to enable (MK4 to 6)
byte 3 = 00 to disable or 01 to enable (MK7)
Multizone remote control
stations
n+1 19 byte 1 = RF zone to set (00 to 0F)
byte n = station to disable (01 to 0A) or group to enable
(0B or 0C) or derived frequency (1F to FF) see
Table 33
Must page time 03 21 byte 1,2 = maximum time that a page may remain in the
system before forcing a zone change. 512 ms
for each increment of this value. Default is
00B0 (176 decimal) for 90 seconds.
NEC D2 batching (obs) 02 0F nn = # seconds in batching period default = 30 sec
NEC D3 batching (obs) 02 10 nn = # seconds in batching period default = 30 sec
No operation 01 00 None
Output Level for High Level
Guard Tone (HLGT)
generation
(version 1B0 and later)
02 3A nn = Will set HLGT directly as a percentage of full
amplitude
For Crescent HLGT = 1.5 x nn
For SCM HLGT = nn/2
**default = C2 (hex) = 194 (decimal)
Paging hold off time 03 22 byte 1,2 = minimum time that a page must remain in
the system before causing a new key-up. Also
used for the minimum time a page must be in the
system to prevent a zone change when pages
pending for other zones have not met the “must
page” time. 512 ms per increment of this value.
Default is 003B (59 decimal) for 30 seconds.
POCSAG alpha EOS char 02 2D nn = ASCII code to use for the End Of String
terminator for alpha-numeric messages. This is
specific to the pager in use and is not usually to be
changed. Default is 04. Typical alternate is a
space (20 hex).
POCSAG batching (obs) 02 0C nn = # seconds in batching period default = 30 sec
POCSAG batchsize limit n+1 32 byte 1 = 512 baud batch size limit.
byte 2 = 1200 baud batch size limit.
byte 3 = 2400 baud batch size limit.