OPARAM.CDS File
Table 32: Station Card OPARAM Codes (continued)
(**) = default value for parameter
Table 33: Setting Control Tones for Multizone Remote Stations
Meaning cc pp qq ...
Zone parameters 0A
0E
1B byte 1 = zone to set (00 to 0F)
byte 2 = mode: 0 = No M68, use default parameters
1 = No M68, use following parameters
2 = M68 key, use default parameters
3 = M68 key, use following parameters
byte 3,4 = Busy Time (TBSY), in msec (See parameter 01)
byte 5,6 = Mode Switching Time (TMOD), in msec
(See parameter 04)
byte 7 = Digital Polarity: 1 = normal, 0 = inverted
(See parameter 06)
byte 8 = Key type 0-8 (See parameter 07)
byte 9 = Grant between pages, minutes (0=none)
(See parameter 16)
The above values, plus the following:
byte 10, 11 = Grant Time (TGRANT) in msec
(see parameter 12)
byte 12, 13 = Gap time (TGAP) in msec (see parameter 27)
byte n (hex)
Station Number
GroupI GroupII GroupIII
Frequency
(decimal)
01 1 11 21 1750 Hz
02 2 12 22 1650 Hz
03 3 13 23 1550 Hz
04 4 14 24 1450 Hz
05 5 15 25 1350 Hz
06 6 16 26 1250 Hz
07 7 17 27 1150 Hz
08 8 18 28 1050 Hz
09 9 19 29 950 Hz
0A 10 20 30 750 Hz
0B Function Tone 1950 Hz
0C Group I Enable tone 2175 Hz
0D Group II Enable tone 1850 Hz
0E Group III Enable tone 2050 Hz
0F to 1E Invalid, do not use
1F to FF Derived Frequency = n * 10 (decimal)
that is: if n = 80 (hex), then Freq. = (128*10) = 1280 Hz