Specifications
System Configuration Files
268 025-9035AA
used to replace an 800 number into End-to-End lines. On End-to-End lines, the number of 
subscriber digits expected is the same for any pass through the call-recycling loop.
MaxRecycle OFF ; do not allow call recycling (default)
MaxRecycle 0  ; do not allow call recycling
; The default value is OFF
MaxRecycle 1  ; do not allow call recycling (only 1 call)
MaxRecycle nnn ; Allow a caller to perform up 'nnn'-1
; recycle operations. This means that
; a caller may place 'nnn' pages.
; nnn = 2-255.
MaxTalkback
On systems with the Talkback option, you can set the maximum number of Talkback calls 
that can be queued up waiting for their turn on the air. This is similar to Load Management 
settings, already discussed. 
 MAXTALKBACK 5
 CHANNEL 2
 MAXTALKBACK 2
 CHANNEL 3 4
Values: 1 to 250; 0, OFF, NONE, or NO to disable; or DEFAULT
Default if missing or DEFAULT: 2
MinimumVoice / MinimumData / MinimumPrompt
The MinimumVoice, MinimumData, and MinimumPrompt commands set thresholds for 
the amount to consider “empty”. The number is the seconds of voice for MinimumVoice 
and MinimumPrompt; number of digits for MinimumData. These parameters are 
especially useful for preventing people from recording custom or system prompts that are 
too short, and/or to make the meaning of Page With Empty Message in the database more 
strict. Times are +- 1 sec. The default if missing is OFF or 0 (no threshold); but we 
factory-set it as follows so that the Page With Empty Message feature works better, and so 
that system operators do not have trouble with people recording too-short custom prompts: 
 MINIMUMVOICE 2
 MINIMUMDATA 1
 MINIMUMPROMPT 2
Values allowed are 0 through 15, or OFF (OFF is same as 0)
ModemBaud
The ModemBaud command was added in version 310j0 to support the fact that many 
modem cards now have autobaud capabilities. The autobaud feature will support baud 
rates of 300, 1200, 2400, 4800, 9600, and 14400. options.cus sets the maximum 
communication speed of the modem card (default is 1200 baud). The format for the 
options.cus command line is: 
Note In order for MinimumVoice and MinimumData to work, the 
subscriber must have the “Send Empty Message” field in the 
subscriber database set to “NO”. This field is found in ZbaseW 
when specifying the capcode for a subscriber.