Specifications
Installing the Office Software
68 025-9035AA
operations. One line is used by your computer modem, and the other goes into a modem 
card in the paging terminal (the maintenance line discussed in the previous subtopic). 
If the terminal and computer are physically near each other, you should consider whether 
or not want to use Local Connect. 
The line used by your computer modem does not need to be a dedicated line. For example, 
in many offices you could share the line that goes to the telephone on your desk with the 
modem in your computer. Be aware that in this case, while you are linked up to the paging 
terminal, nobody will be able to call you. The line must not have Call Waiting, since the 
beeps or clicks used to indicate an incoming call are known to interfere with modem 
operations. 
Some people use one of their low-use business lines for the computer modem line. This 
usually works well, as long as there is no Call Waiting on that line and people are not 
going to pick up the line while you are linked to the paging terminal. 
Local Connection
You might want to use Local Connect if the computer is located close to the terminal 
(within 50 feet or so). It provides a direct connection between a serial port in the paging 
terminal and a serial port on your computer. Its advantage is that it does not consume any 
telephone lines while linked up to the terminal, and the serial connection is usually faster. 
(Please note that a maintenance line for Zetron use is still required as discussed 
previously). 
If you do use Local Connect, the computer will need to be reasonably close to the paging 
terminal. We can provide a 60-foot cable to connect between them. We do not recommend 
that you attempt a cable run much longer than this. 
With Local Connect, the modem maintenance port on the terminal probably will not be 
used much. You might use it to call from a computer at home or a portable computer from 
somewhere else, for instance to watch paging traffic, but this is not very common. More 
likely, the maintenance port would only be used by Zetron Technical Support, when you 
wanted us to check on or change something. 
Note Even if you use Local Connect, and thus have both Serial and 
Modem maintenance ports installed in the paging terminal, only 
one can be active at a time. In other words, the paging terminal 
will not allow more than one computer to access its database or do 
maintenance operations at the same time. This means that when 
you ask us to access your paging terminal to do something, you 
must be sure you are not watching traffic nor in ZlinkW, otherwise 
we will not be able to link up.