Datasheet

E/F6 Series, E/F7 Series panel mount switches
E/F6 are single pole versions, E/F7 are double pole
versions
∙ Push buttons in various models
∙ Snap-in panel mounting
∙ Long-life coil spring, snap-action mechanism
∙ Agency approved extended-life versions available
∙ VDE approval available on select models (F Series)
∙ Various terminal forms available (consult factory)
E/F6 SERIES, E/F7 SERIES
PANEL MOUNT SWITCHES
Not every confi gurable variant is available for order. Please contact us.
The fi nal two digits of article numbers on commercial documents refer to the
index of the respective drawing.
Customer-specifi c models are marked with a G or W as the sixth digit of the
article number.
Technical specifi cations
Series Panel mount switch
Electrical
Ambient temperature 40° to + 85°C
Flammability rating UL94V-O
Materials
Housing Thermoplastic Polyester,
Valox (single pole versions),
Vandar (double pole versions)
Actuator Thermoplastic Acetal (E Series), Valox
Terminals* Brass
Moving blade Beryllium Copper
Spring Stainless steel
Contacts
E65, E/F69, E/F77, E/F79
E/F68, E/F78
AgCdO
Au (Crosspoint)
* Common terminals are plated – the remaining terminals are not plated.
Approvals
Approvals Code
UL E
VDE & UL F
Confi guration
Confi guration Code
Singe pole version 6
Double pole version 7
Actuator
Terminal type Code
Basic momentary 00A
Push-pull momentary 20A
Momentary (cheat interlock) 30A
Short button momentary 40A
Momentary for auxiliary actuator 50A
Terminals
Series Terminals
E68, E69, E77, E78, E79 Q.C. terminal 4.8 x 0.5 mm
E65, E75, F68, F69, F77, F78, F79 Q.C. terminal 4.8 x 0.8 mm
Electrical rating and operating life
Electrical rating
according to
Electrical life for 40T85
(operations)
Code
EN 61058-1 UL 1054 acc. to EN acc. to UL
- 16A, 125/250V AC; 1/3HP, 125/250V AC 6,000 5
0.1(0.05) A, 125V AC; 10(4)A, 250V AC 0.1A, 125V AC; 10A, 1/3HP, 125/250V AC 50,000 6,000* 7
0.1(0.05) A, 125V AC 0.1A, 125V AC 50,000 6,000* 8
10(4) A, 250V AC 10A, 125/250V AC; 1/3HP, 125/250V AC 50,000 6,000* 9
* Other ratings available upon request
Generation of order code (example)
The order code consists of 5 parameters:
❶❷❸❹
Series Approvals Circuitry Electrical rating Actuator
Panel mount
switc
h
F
= UL & VDE
6
= Singe pole
version
9
= 10(4)A, 250V AC
00A
= Basic
momentary
- 00A
A
- 20A
A
- 30A
A
- 40A
A
- 50A
A
- 30A
A
Basic momentary
(Makes contact
while actuated)
Push-pull (Push:
makes contact, Pull:
reset position)
Momentary
(If pushed: normal
pushbutton function)
Cheat interlock
(If pulled: permanent
contact function)
Pulled out
Short button momentary
(Makes contact
while being actuated)
Momentary – for auxiliary
button (Makes contact
while being acutated)
Ø 0.315
Actuator (function)
COM
NC NO
Cut out 1.115 (28.32) for
0.045 (1.14) thick panel
Cut out 1.125 (28.58) for
0.100 (2.54) thick panel
0.865
(21.97)
1.010 (25.65)
0.145 ± 0.020
(3.683 ± 0.51)
0.770 ± 0.050
(19.56 ± 1.27)
Operating point
0.875
± 0.030
(22.23 ± 0.76)
Rest position
0.156 (3.96)
0.367
± 0.020
(9.32 ± 0.51)
0.099 (2.51)
0.145 (3.68)
0.375
(9.53)
Reference line
Thick mounting panel
(see panel cutout detail)
0.97
(24.64)
0.080
(2.03)
0.843
(21.41)
0.615
(15.62)
0.68
(17.27)
0.46
(11.68)
1.25
(31.75)
Ø 0.34
(Ø 8.64)
R 0.060
(R 1.52)
0.510 (12.95)
0.540 (13.72)
0.050
(1.27)
R max.
Panel
cutout detail
0.550
(13.97)
Singe pole version
Operating point
Rest position
Reference line
Thick mounting panel
(see panel cutout detail)
COM COM
NC NO NCNO
0.050 (1.27)
R max.
Cut out 3.413 (86.70) for
0.045 (1.14) thick panel
Panel
cutout detail
Cut out 1.455 (36.96) for
0.100 (2.54) thick panel
0.045 (1.14)
0.100 (2.54)
0.97
(24.64)
0.080
(2.03)
1.24
(31.5)
Ø 0.34
(Ø 8.64)
0.68
(17.27)
0.375
(9.53)
0.79
(20.07)
1.75
(39.88)
R 0.060
(R 1.52)
0.510 (12.95)
0.540 (13.72)
0.550
(13.97)
Double pole version
Dimensions in inch (mm)
For detailed information please note the technical specifi cations which you can fi nd in the download section of our website www.switches-sensors.zf.com.

Summary of content (1 pages)