Data Sheet

0.250±.030
(6.35±0.76)
4
3
1
ø0.115
(ø2.92)
See Detail A
Approximate
Sensing
Location
0.642
(16.31)
0.015
(0.38)
2X 45° X
0.020 (0.51)
0.855 (21.72)
0.120
(3.05)
0.228
(5.79)
0.680
(17.27)
Active Surface
0.115
(2.92)
2X R
0.130 (3.30)
0.075 (1.91)
Approximate
Label Location
0.324 (8.23)
47.8
2X R 0.104
(2.64)
0.105
(2.67)
0.210
(5.33)
Detail A
Leads = 24 AWG PVC UL1569, pre-tinned.
All tolerances 0.007 (0.18) unless otherwise noted.
12±0.75
(304.8±19.05)
Magnet
1
3
4
VCC
(red)
Pull-up
Resistor
Output
(green)
Ground
(black)
MP1014 Series
Digital Hall-effect position sensor in low-pro le fl ange-mount housing.
Features
Capable of millions of operations
Reverse Battery Protection to -24 V DC
MP101401 south pole activated unipolar switching
RoHS Compliant
Latching versions available on special order basis
Specifi cations
Part Number
Operating
Voltage Range
(VDC)
Supply
Current
(mA max.)
Output
Output
Saturation Voltage
(mV max.)
Output
Current
(mA max.)
Operating
Temp Range
(°C)
Function
Operate
Point Gauss
(max.)
Release
Point Gauss
(min.)
MP101401
4.5 – 18 5.2 3-wire sink 400 20 40 to 85 Unipolar Switch 139 (south) 47 (south)
MAGNETIC SENSOR
Dimensions
inches (mm)
All tolerances ±0.005 (0.13) unless otherwise noted.
Specifi cations subject to change without notice.
Open Collector
Sinking Block Diagram
Applications
Door position sensing
Flow sensing
Pedal switch
Notes: These sensors require the use of an external pull-up resistor, the value of which is dependent on the supply voltage. See page 27 for recommendations.
Pull-up resistor should be connected between output (Green) and Vcc (Red).
Unipolar switch output turns low in presence of magnetic south pole. Bipolar latch output latches high in presence of magnetic south poles and latches low in presence of magnetic north pole.
6

Summary of content (1 pages)