User's Manual

17
Table 3-5 Wiegand output
Parameter Description
Wiegand output type
The
Wiegand output type determines the card number or the digit of
the number than can be recognized by the standalone.
Wiegand26, three bytes, six digits.
Wiegand34, four bytes, eight digits.
Wiegand66, eight bytes, sixteen digits.
Pulse Width
You can set pulse width and pulse interval.
Pulse Interval
Output Data Type
You can select the types of output data.
User ID: If User ID is selected, and then user ID will be output.
Card No.: If Card No. is selected, and then card number will be
output.
3.8.3 TCP Port
The range is 1025-65535, and it is 37777 by default. If you modify the port, the system will
restart automatically.
3.8.4 Serial Port Settings
Select serial input or serial output according to the entering direction and exiting direction.
Select Comm > Serial Port.
Serial port Figure 3-11
Select Serial Input when external devices that are with card reading and writing functions
are connected to the standalone. Serial Input is selected to enable access card
information to be sent to the standalone and the management platform.
For standalones with fingerprint recognition, card reading and writing functions, if you
select Serial Output, standalone will send card number or user ID to the controller.