Figure 3-3 Door parameter
Table 3-1 Description of door parameters
Parameter Description
Name Enter a name of the door.
State
Set the door status.
NO
: The door remains unlocked all the time.
NC
: The door remains locked all the time.
Normal
: If
Normal
is selected, the door will be unlocked
and locked according to your settings.
Opening Method
Unlock by Period: Set different unlock methods for
different periods.
Group Combination: The user can unlock the door only
after defined users or user groups grant access.
Unlock Mode: Set unlock combinations.
Hold Time (Sec.)
After a person is granted access, the door will remain
unlocked for a defined time for them to pass through. It
ranges from 0.2 s to 600 s.
Normally Open Time
The door remains open or closed during the defined period.
Normally Close Time
Timeout (Sec.)
A timeout alarm will be triggered if the door remains
unlocked for longer time than this value.
Open with remote verification
Set the remote verification door opening period. After users
gain access on the Access Controller, they must also be
granted access from the management platform before the
door unlocks.