User's Manual

26
Wiegand Figure 3-14
Select Wiegand Input when an external card swipe mechanism is connected to the
access controller.
Select Wiegand Output when the access controller works as a reader that can be
connected to the controller.
Table 3-8 Wiegand output
Parameter
Description
Wiegand Output Type
The Wiegand Output Type determines the card number or the digit
of the number that can be recognized by the access controller.
Wiegand26, three bytes, six digits.
Wiegand34, four bytes, eight digits.
Wiegand66, eight bytes, sixteen digits.
Pulse Width
You can set pulse width and pulse interval.
Pulse Interval
Output Data Type
You can select the types of output data.
User ID: If User ID is selected, and then user ID will be output.
Card No.: If Card No. is selected, and then card number will be
output.
System 3.10
3.10.1 Time
You can do date format setting, date setting, time setting, DST setting, NTP check, and time
zone settings.
When you select Network Time Protocol (NTP), you need to enable the NTP Check
function first. Server IP Address: enter the IP address of the time server, time of the access
controller will be synchronized with the time server.
Port: Enter the port number of the time server.
Interval (min): NPT check interval. Tap the save icon to save.