Modifying alarm linkage parameter Figure 4-8
Table 4-1 Alarm linkage parameter description
Parameter
Description
Alarm Input
You cannot modify the value. Keep it default.
Name
Enter a zone name.
Alarm Input Type
There are two options: NO and NC.
If alarm input type of the alarm device that you purchased is NO, select
NO; otherwise you should select NC.
Fire Link Enable
If fire link is enabled the access controller will output alarms when fire
alarms are triggered. The alarm details will be displayed in the alarm
log.
Alarm output and access link are NO by default if fire link is enabled.
Alarm Output
Enable
The relay can output alarm information (will be sent to the
management platform) if the Alarm Output is enabled.
Duration (Sec.)
The alarm duration, and the range is 1300 seconds.
Alarm Output
Channel
You can select an alarm output channel according to the alarming
device that you have installed. Each alarm device can be regarded as
a channel.
Access Link
Enable
After the Access Link is enabled, the access controller will be
normally on or normally closed when there are input alarm signals.
Channel Type
There are two options: NO and NC.
Click OK. Step 3
The configuration on the web will be synchronized with the configuration in the client if the
access controller is added to a client.