User's Manual

63
Parameter
Description
value is greater than 19.
Infrared Light
Adjust IR brightnees by dragging the scroll bar.
Recognition
Timeout
When a person who does not have the access permission stands in
front of the access controller and gets the face recognized, the
controller will prompt that face recognition failed. The prompt interval
is called recognition timeout.
Invalid Face Prompt
Interval
When a face has no access permission stands in front of the access
controller, the controller will prompt that the face is invalid. The prompt
interval is invalid face prompt interval.
Pupillary Distance
Pupillary distance is the pixel value of the image between the centers
of the pupils in each eye. You need to set an appropriate value so that
the access controller can recognize faces as needed. The value
changes according to the face sizes and the distance between faces
and the lens. The closer the face is to the lens, the greater the value
should be. If an adult is 1.5 meters away from the lens, the pupillary
distance value can be within 50 to 70.
Enable Face
Exposure
After face exposure is enabled, human face will be clearer when the
access controller is installed outdoors.
Channel Id
There are two options: 1 and 2. 1 is white light camera and 2 is IR light
camera.
Draw Target
Click Draw Target, and then you can draw the minimum face
detection frame.
Click Remove All, and you can remove all the frames you drew.
Detect Region
Click Detect Region, move your mouse, and you can adjust the face
detection region.
Click Remove All, and you can remove all the detection regions.
Face Target
Brightness
The default value is 50. Adjust the brightness as needed.
Face Exposure
Interval
After a face is detected, the access controller will give out light to
illuminate the face, and the access controller will not give out light
again until the interval you set has passed.
Temperature
Monitoring
Set whether to enable the body temperature monitoring.
Temp Unit: Select a temperature unit.
Temp Rect: Set whether to display the temperature monitoring
box or not.
Temp Monitoring Distance (cm): the end user cannot adjust the
setting to below 20 cm distance between end user and the
device.
Temp Threshold C): Set the temperature threshold. The
monitored body temperature will be judged as high temperature if
it is greater than or equal to the set value.
Temp Correction Value: This parameter is for testing. The
difference of the temperature monitoring environment might
cause the temperature deviation between the monitored
temperature and the actual temperature. You can select multiple
monitored samples for testing. According to the comparison