User's Manual

62
Parameter
Description
Light value is greater than 19.
Infrared Light
Adjust IR brightnees by dragging the scroll bar.
Recognition Timeout
When a person who does not have the access permission stands in
front of the terminal and gets the face recognized, the terminal will
prompt that face recognition failed. The prompt interval is called
recognition timeout.
Invalid Face Prompt
Interval
When a face has no access permission stands in front of the
terminal, the terminal will prompt that the face is invalid. The
prompt interval is invalid face prompt interval.
Pupillary Distance
Pupillary distance is the pixel value of the image between the
centers of the pupils in each eye. You need to set an appropriate
value so that the terminal can recognize faces as needed. The
value changes according to the face sizes and the distance
between faces and the lens. The closer the face is to the lens, the
greater the value should be. If an adult is 1.5 meters away from the
lens, the pupillary distance value can be within 50 to 70.
Enable Face Exposure
After face exposure is enabled, human face will be clearer when
the terminal is installed outdoors.
Channel Id
There are two options: 1 and 2. 1 is white light camera and 2 is IR
light camera.
Draw Target
Click Draw Target, and then you can draw the minimum face
detection frame.
Click Remove All, and you can remove all the frames you drew.
Detect Region
Click Detect Region, move your mouse, and you can adjust the
face detection region.
Click Remove All, and you can remove all the detection regions.
Temperature
Monitoring
Set whether to enable the body temperature monitoring.
Temp Unit: Select a temperature unit.
Temp Rect: Set whether to display the temperature monitoring
box or not.
Temp Monitoring Distance (cm): The end user cannot adjust
the setting to below 20 cm distance between end user and the
device.
Temp Threshold C): Set the temperature threshold. The
monitored body temperature will be judged as high
temperature if it is greater than or equal to the set value.
Temp Correction Value: This parameter is for testing. The
difference of the temperature monitoring environment might
cause the temperature deviation between the monitored
temperature and the actual temperature. You can select
multiple monitored samples for testing. According to the
comparison between the monitored temperature and the
actual temperature, you can correct the temperature deviation
by this parameter. For example, if the monitored temperature
is 0.5°C lower than the actual temperature, the correction
value is set to 0.5°C; if the measured temperature is 0.5°C