User's Manual

Table Of Contents
5
Port
Cable Color
Cable Name
Description
Blue
CASE
Tamper alarm input of the external card reader.
White
D1
Wiegand D1 input (connected to external card
reader)/output (connected to controller).
Green
D0
Wiegand D0 input (connected to external card
reader)/output (connected to controller).
Brown
LED
Connected to external reader and verify card
number.
Yellow
B
RS-485 negative electrode input (connected to
external card reader)/output (connected to
controller, or connected to door control security
module).
If the security module is enabled, you need to
purchase access control security module
separately. The security module needs
separate power supply to provide power.
Once the security module is enabled, the exit
button, lock control and firefighting linkage will
be invalid.
Purple
A
RS-485 positive electrode input (connected to
external card reader)/output (connected to
controller, or connected to door control security
module).
If the security module is enabled, you need to
purchase access control security module
separately. The security module needs
separate power supply to provide power.
Once the security module is enabled, the exit
button, lock control and firefighting linkage will
be invalid.
CON2
White and
red
ALARM1_N
O
Alarm 1 normally open output port.
White and
orange
ALARM1_C
OM
Alarm 1 common output port.
White and
blue
ALARM2_N
O
Alarm 2 normally open output port.
White and
gray
ALARM2_C
OM
Alarm 2 common output port.
White and
green
GND
Connected to the common GND port.
White Brown
ALARM1
Alarm 1 input port.
White and
yellow
GND
Connected to the common GND port.
White and
ALARM2
Alarm 2 input port.