Parameter
Description
Timeout
door exceeds the Door Sensor Timeout time.
The Door Sensor Timeout time range is 1–9999 seconds.
Door Sensor
On
Only when the Door Sensor On is enabled can the intrusion alarm and
door sensor timeout alarm be triggered.
3.8.4 Door Status
There are three options: NO, NC, and Normal.
NO: If NO is selected, the door status is normally open, which means the door will never be
closed.
NC: If NC is selected, the door status is normally closed, which means the door will not be
unlocked.
Normal: If Normal is selected, the door will be unlocked and locked depending on your
settings.
3.8.5 Lock Holding Time
Lock Holding Time is the duration in which the lock is unlocked. If the lock has been unlocked
for a period that exceeds the duration, the lock will be automatically locked.
Network Communication
To make the access controller work normally, you need to configure parameters for network,
serial ports and Wiegand ports.
3.9.1 IP Address
3.9.1.1 IP Configuration
Configure an IP address for the access controller and connect it to the network.