Mobile Digital Video Recorder User’s Manual V1.0.
Regulatory Information The regulatory information herein might vary according to the model you purchased. Some information is only applicable for the country or region where the product is sold. FCC Information Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC conditions: This device complies with part 15 of the FCC Rules.
Cybersecurity Recommendations Mandatory actions to be taken towards cybersecurity 1. Change Passwords and Use Strong Passwords: The number one reason systems get “hacked” is due to having weak or default passwords. It is recommended to change default passwords immediately and choose a strong password whenever possible. A strong password should be made up of at least 8 characters and a combination of special characters, numbers, and upper and lower case letters. 2.
In the event that your social media, bank, email, etc. account is compromised, you would not want someone collecting those passwords and trying them out on your video surveillance system. Using a different username and password for your security system will make it more difficult for someone to guess their way into your system. 9.
Foreword Models DHI-MXVR4104-GCW MxVRmnpq-abcd,DHI-MxVRmnpq-abcd,DHI-DAE-MxVRmnpq-abcd x=X or C or N or H; m=1,2,3,4,5,6,7,8,9; n=0,1,2,3,4; pq=04,08,12,16,20; a=G, B or blank; b=C,F,A,E or blank; c=W or blank d= I or blank The models above only include WCDMA Band 2 function. Safety Instructions The following categorized signal words with defined meaning might appear in the Guide.
“Smart module” in this manual means smart cards installed on devices. “IP host” in this manual refers to hosts configured with IP addresses. PC, NVR, IPC, and speed domes are all IP hosts. To keep the devices safe, IP addresses, MAC addresses, and serial numbers cited in this manual have all been modified. Revision History No. Version Revision Content Release date 1 V1.0.
Important Safeguards and Warnings The following section describes how to use this product correctly and how to prevent dangers and property loss in using it. Before using this product, read this Manual carefully and comply with it strictly. Keep this Manual properly after reading. Requirements Do not place or install the device near a heat source or where there is direct sunshine. Do not install the device in a humid, dusty, or smoggy place.
Take care to complete the circuit connection. A failure to follow this instruction might result in Device damage. Prevent short circuit from occurring on all external wiring parts. After all the lines connections are completed, you can start connecting power cable. Ensure the project is well grounded to avoid interference to video and audio signals and avoid electrostatic or induced voltage to damage the Device.
Table of Contents Regulatory Information ...........................................................................................................................I Cybersecurity Recommendations ........................................................................................................II Foreword ............................................................................................................................................... IV Important Safeguards and Warnings ...................
4.5.4 Abnormality .....................................................................................................................70 4.5.5 Configuring Alarm Output Settings ..................................................................................72 4.5.6 Searching Alarm Log .......................................................................................................73 System config .......................................................................................................
System Update ........................................................................................................................197 5.6.1 View system version......................................................................................................197 5.6.2 Upgrading System Firmwares .......................................................................................197 System Maintenance ....................................................................................................
1 Product Introduction Product Overview Based on the new generation platform, the MXVR4104 series products are onboard video monitoring products that integrate video capturing, locating, and drive recording. Features: Up to 4-channel coaxial video input and 4-channel remote video input. Compatible with AHD, TVI, and CVBS video signals. The use of H.264/H.265 encoding ensures high encoding efficiency and saves storage space.
Function Description Alarm linkage Provides eight routes of electric level alarm inputs that can connect to signals such as car door signal, cornering lamp signal, reversing and braking signal, to give an indication and take a record Supports 2 routes of electric level alarm output to realize easy alarm linkage Supports protective circuit for alarm input port and alarm output port, which protect the Device from damage.
2 Dimension and Installation Describes the installation of hardware. Prior to installation, you need to know about the front panel, rear panel, structural sizes, and interface definition of the device. Then you can install corresponding HDD, SIM card, SD card, antenna, and devices. Out-of-box Audit When you receive the Device, unpack the box for checks.
No. Name Descriptions of interfaces and indicators When pulling out HDD, the Device must be unlocked, and if the Device is turned on, it will shut down automatically. To protect the HDD, this Device cannot be turned on if it is unlocked. Turning on the device only after locking it 2 Lock switch (Device switch) 3 PWR The red light is always on when the Device is powered on, and off when the Device is powered off 4 REC Recording status indicator.
No. 1 Name CH1-4 Function Connects to HDCVI or analog mobile camera, such as CVBS, TVI, and AHD. Refer to "2.2.3.1 CH1-4 Port" for details. NOTE Different devices corresponds to different number of channels ETH interface The aviation port can be converted to an RJ45 interface through a adapter cable. Access to PoE power switch to realize IPC remote access. Connects to the network to realize the login and Web interface operation of the Device.
2.2.3.1 CH1-4 Port CH1-4 port Table 2-3 Port description No. Description 1 12V power supply to camera. 2 Grounding port. 3 Grounding port. Video input port to receive video signal from camera. 4 When your camera is the kind which outputs AHD, TVI or CVBS video signal, the Recorder can only receive the video signal and cannot receive the audio signal; when your camera is the kind which outputs CVI video signal, the Recorder can receive both the video and audio signal. 2.2.3.
2.2.3.3 VGA Port VGA interface No. Function No. Function No. Function 1 +12V/1A output 5 Audio output 9 VGA line sync 2 Ground line 6 VGA_B 10 VGA line sync 3 VGA_G 7 VGA_R - - 4 RXD_232 8 TXD_232 - - 2.2.3.4 EXTEND port EXTEND port Name Function +5 USB +5V (upper line) +5 USB +5V (upper line) + USB data- and USB data+ that connect to USB port. IR Remote control signal indicator. Receives signals from remote control. +12 +12V/1A output.
2.2.3.5 Voice talk port Voice talk port Name Function +12 +12V output Ground Mic In that can connect to microphone. Mic Out that can connect to earphone. SPK+ Speak positive pole SPK- Speak negative pole 2.2.3.6 External pickup port External pickup port Name Function +12 +12V output Ground Mic In that can connect to pickup.
2.2.
Hangers Installation Dimension Diagram (mm) Installation When you receive the Device, unpack the box to check the Device appearance and structures, and then install the SIM card, SD card, and HDD. NOTE Before the installation is complete, make sure the Device is disconnected from power, and do not plug or unplug components when the power is connected. When installing and taking out HDD, the Device electronic lock must be in "unlocked" status.
Turn on the door locker switch Loosen the two screws at the front panel and take out the HDD carrier along the guide rail. Take out HDD box. Loosen two screws on the back panel of the HDD carrier, take out the rear carrier panel, and remove the HDD carrier enclosure.
Loosen two screws of the HDD holder and remove the holder. Disassemble HDD holder Use four screws to fix the HDD and HDD holder, and install the HDD holder back to the Device. Installing HDD Install the HDD carrier enclosure in place along the rails, and then fix the HDD enclosure rear panel with two screws. Place the HDD carrier back to the Device, tighten two screws and close the door lock.
2.3.2 Installing SIM Card and SD Card By default, the Device is delivered without the SIM card and SD card. Install them as you need. To connect the Device to Internet through dial-up connection, you need to purchase and install a SIM card. NOTE Only supports normal SIM card. To store recording data, you need to purchase and install an SD card. Preconditions Make sure the power supply is disconnected. If it is not, the Device automatically shuts down when the door lock switch is opened.
2.3.3.1 Installation of Mobile Network Antenna CAUTION When installing sticking antenna, make sure there is no metal material below the sticking spot. For installation of mobile network antenna, see Figure 2-17. The flat antenna is recommended to be vertically attached to near the wind shield (such as on the instrument panel, or under the wind shield), or concealed inside the instrument panel. Inside installation of Mobile Network Antenna 2.3.
Fix the Device onto the vehicle. Connect cables to the Device. Check the voltage of the accumulator. The working voltage of this Device ranges from 6V to 36V. To make sure the Device works stably, directly get power supply from the accumulator. When installing the basic wires, do not use excessive force to pull the control wires. 2.3.5 Connecting to Power Cables CAUTION Before connecting the power cable, confirm whether the input voltage is between 6V DC and 36V DC.
2.3.5.2 Obtain Connection Modes of the Main Power Switch In order to ensure correct cable connection, it is necessary to obtain the connection mode of the main power switch through three methods (is the main power switch connected to the positive or negative pole of the battery?). Ask the vehicle manufacture the connection modes of the main power switch of the vehicle.
Vehicle main power switch installed on the positive pole of the vehicle battery Vehicle main switch installed on the negative pole of the vehicle battery Audio and Video Output Connection This section helps you understand the connection of audio and video input and output when you need to use this function. Introduction of Video and Audio Output Port The four-cored aviation port (Figure 2-25) can output the video and audio data.
Four-cored aviation port No. Function 1 12V external power source and no more than 1.5A. 2 Ground line 3 Audio port 4 Video port Video Output The Device is provided with one CVBS (PAL/NTSC 1.0VP-P, 75Ω) port and VGA port, and supports the simultaneous output from these two ports. Read the following contents carefully before using the computer instead of monitor. For VGA output, you need to prepare a VGA adapter cable to connect to computer.
PTZ Decoder Connection The common-ground must be prepared for PTZ decoder and the Device; otherwise the common-mode voltage might not be able to control the PTZ. It is recommended to use shielded twisted pair, and the shielding layer can be used for common ground. Prevent interference from high-voltage power, make reasonable wiring, and take measures for lighting protection. Parallel connect 120Ω resistance to reduce reflection and ensure high signal quality.
2.5.2 Alarm Input Port Both NO and NC are supported. The GND of alarm detector is in parallel connection with COM (the power supply of alarm detector should be from external power source). See Figure 2-27. The GND of alarm detector is in parallel connection with GND of Device. Connect the NC port of alarm detector to the alarm input port (ALARM). When supplying power from external power source to the alarm device, the alarm device should be common-grounded with the Device.
3 Boot up the Device CAUTION Before booting up the Device, check if input voltage matches rated voltage of the Device. Refer to international standard to offer the power input (power input that is with stable power value and less interference ) to ensure the Device works stably and prolong its service life. In the first power-on, the Device needs connection to the ACC to work as intended. Rotate the Device key to and rotate the vehicle key to ACC position.
4 Local Configurations The Device supports access and operation through the local interface. The local interface supports functions such as real-time preview, recording search, alarm setting, system setting, PTZ control interface, and monitoring window. Initializing Device Plug the device’s power line into a socket. After the Device is turned on, the initialization interface is displayed. See Figure 4-1.
Unlock Pattern Draw and confirm an unlock pattern. If you do not want to configure the unlock pattern, click Skip. The password protection interface is displayed. See Figure 4-3. Password protection Configure the protection method for password. If you do not want to set the protection, clear both the Reserved Phone Number check box and the Security Question check box. Select Reserved Phone Number and enter the phone number. The phone number must be 11-digit number and can be normally communicated.
Logging into the Device Boot up the Device. The main interface is displayed. See Figure 4-4. Homepage Right-click on the live view screen, the shortcut menu is displayed. Then select Main Menu. The SYSTEM LOGIN interface is displayed. See Figure 4-5. Logging in System NOTE If the unlock pattern was set during initializing, the unlock pattern login interface is displayed. Then use the unlock pattern to login. Click to view the password hint to help you recall the password.
security questions or reserved phone number. Select the admin user, and enter the corresponding password that was set during initialization. Click OK. The Main Menu interface is displayed. See Figure 4-6. Main menu Quick Configuration After initialization, to ensure normal operation, quickly and conveniently configure basic information, network connection, remote device adding, and recording schedule on the Device. 4.3.
TCP/IP Configure TCP/IP parameters. For details, see Table 4-1. Table 4-1 TCP/IP parameter description Name Description Select IPv4 or IPv6.
4.3.2 Configuring General Settings To facilitate the application of user, configure basic information of the Device as needed for the first time. 4.3.2.1 General Configure Language, Auto Logout Time, IPC Time Sync, License No. of the vehicle and other information. Select System Management > General Setup> Local Settings under the main menu. The General interface is displayed, see Figure 4-8. General Configure TCP/IP parameters. For details, see Table 4-2.
4.3.2.2 Date and time settings Inconsistent system time among devices in a same network might cause failure of query, recording playback and other problems. Select System Management > General Setup> Date&Time under the main menu. The Date&Time interface is displayed. See Figure 4-9. Date and time settings Configure TCP/IP parameters. For details, see Table 4-3.
Name Server Synchronize Port Update Period (minute) Description In the Timing Mode list, if NTP is selected, configure this parameter After configuring NTP server, the Device syncs time with NTP server 3. In the Timing Mode list, select NTP to enable the NTP timing function 4.
Remote device Click Device Search. The searched devices are displayed. Enable Uninitialized function. The uninitialized devices are displayed. Select the check box the uninitialized device, and then click Initialize. The Password Setting interface is displayed. Configure the password by either of the following two ways. Using current device password and phone info. Select the Using current device password and phone info check box, and the remote device uses the password and phone info of the Device.
Directly click Skip if you do not want to set up the network information or correct network information already exists. The device initialization begins. After initialization, click OK. 4.3.3.2 Adding a Remote Device After a remote device is added, you can view video images transferred by the remote device and modify configuration of the remote device directly on the Device. You can add a remote device manually or by search.
NOTE The parameters might be different depending on the model you purchased. Table 4-4 Manual Add Parameter Descriptions Name Description Channel The channel number of the remotely connected device. You can only select a channel that has not added remote devices Manufacturers Select a manufacturer according to the actual situation. Parameters might vary by manufacture. Follow specific parameters on the interface IP address Enter the IP address of remote device TCP Port TCP service port.
4.3.4 Configuring Record Settings When recording and snapshot functions are enabled, the Device can start recording and snapshot according to the configured recording and snapshot schedule. Recording types include automatic recording and manual recording. You can select recording type according to different stream types. Auto: The recording starts automatically according to the record type and recording time as configured in the recording schedule.
Name Description Auto/Manual/Stop Select the recording mode, including Manual, Auto, and Stop Manual: Top priority. When the Manual check box is selected, the system keeps general recording for 24 hours for the corresponding channel Auto: The system starts recording according to the record type (such as general alarm, motion detect, and system alarm) and recording time Stop: Do not record Enable/Disable Enable or disable the scheduled snapshot for the corresponding channels Click Apply. 4.3.
Name Description Channel Select a channel to configure the corresponding recording schedule. To configure the same setting for all channels, select All Pre-record Start recording for 0 seconds to 30 seconds before the alarm event occurs. If you enter 0 seconds, there will be no pre-recording Configure the recording time period. 1) Click corresponding to the week. The Time Period interface is displayed. See Figure 4-14.
Snapshot Configuring time period for taking snapshots. 1) Click .corresponding to the week. The Time Period interface is displayed. See Figure 4-16. Time Period 2) 3) Select the snapshot type and weekday, and enter the period for taking snapshot. Click OK. Snapshot schedule appears on the Snapshot interface to view the configured snapshot schedule directly. Click OK.
Common Operations 4.4.1 Live View 4.4.1.1 Previewing real-time pictures After the Device is turned on, the multi-channel preview interface is displayed. See Figure 4-17. For icon descriptions, see Table 4-7. TIPS See .On the live view interface, the added remote device can be dragged to other channel if needed. You can view the information such as time, channel name, and recording and alarm status in the channel view.
Table 4-7 Information Bar Status Description Displays the ACC status of the vehicles Vehicle ACC status Voltage status means ACC ON; means ACC OFF Displays the accumulator voltage of the vehicle and the voltage of the UPS carried by the Device. The voltage value on the left is the accumulator voltage. The voltage value on the right is the UPS voltage. means ACC ON; means ACC OFF Displays the vehicle speed.
Right-click menu View layout: Main Menu: Open Main Menu interface. Image splitting: Select View 1, View 4, View 8, and View 9 for image splitting mode. Different model supports different view layout mode. Search: Open the playback interface where you can search and play back record files or pictures. PTZ: PTZ Setting interface is displayed. Remote Device: Search and add a remote device. Manual: Record or Alarm Output interface is displayed. Color Setting: Color Setting interface is displayed.
PTZ Control 4.4.1.3.2 Configuring PTZ Fn On the preview interface, right-click PTZ > PTZ Fn on the channel of the video image enabled in the single-window screen. PTZ Fn interface is displayed. See Figure 4-20. PTZ Fn Configure parameters Click Disable for Image De-Jitter to enable the image de-jitter function. When enabled, electronic image stabilization can be realized. Click Disable for Defog to enable the defog function.
PTZ Shutter Click Disable to enable the PTZ shutter. Click Save. 4.4.1.3.4 Configuring PTZ Functions Click . The PTZ function interface is displayed. See Figure 4-22. SeeTable 4-8 for functions description.
Function Description You can quickly move the PTZ camera to the configured presets after configuration. In the PTZ Setup list, select Preset, and then move the camera to the direction that you want to monitor 5. Preset point 6. 7. 8. Click to select Preset. The Preset interface is displayed. Through the control panel of PTZ, move the camera to the surveillance direction that you need. In the Preset box, enter the preset value Value ranges from 1~255 for preset. Click Set to complete adding preset.
Function Description After setting up scan, the camera automatically scans the configured left border and right border 17. Click Scan to select Border. The Border interface is displayed. 18. Through the PTZ control panel, move the camera to the left border that you want and click Set the left border; move the camera to the right border that you want and click Set the right border. Configuration finished Return to the PTZ function interface. Click Pan Click to enable scan. .
IPC Config Configure TCP/IP parameters. For details, see Table 4-9. Parameters in gray cannot be configured. Table 4-9 Color setting parameters description Name Description Time Period Effective Time Select the time period to enable the effective time, and then enter the time in the box. Brightness Adjusts the image brightness. The bigger the value is, the brighter the image will become Contrast Adjusts the contrast of the images.
Alarm Output Select alarm output mode. Manual: After the alarm linkage is configured, no matter whether there is an alarm event occurs, the corresponding alarm output port keeps generating alarm. Auto: After the alarm linkage is configured, when an alarm event occurs, the corresponding alarm output port generates alarm. Stop: After the alarm linkage is configured, no matter whether there is an alarm event occurs, the corresponding alarm output port never generate alarm. Click Apply.
Zero-Ch Encode Click to enable zero-ch encode. means enabled. Configure TCP/IP parameters. For details, see Table 4-10. Table 4-10 Multi-channel encode parameters description Name Description Encode Mode Encode Mode of video Resolution The higher the video resolution, the better the image quality FPS Configure the frames per seconds for video. The larger the value is, the smoother and more vivid the image will be. Bit Stream Select a value for bit rate of video Click Apply.
Video playback Table 4-11 Play Control Bar Icon Function Description Play When this icon displays, it means the video is paused or not being played, click this icon to play video Stop Click this icon to stop playback Play Backward. Click this icon to rewind. Slow Playback. Click this icon to reduce play speed. Click Speed-up Play Click this icon to increase play speed. Click Audio Drag the slider to adjust the volume. Click to start slow play. to start fast play. to enable mute mode.
in the area. After entering the zoomed in status, you can drag the enlarged area to move to any directions to view details of other parts of image. Right-click on the enlarged image to return to the original status. 4.4.2.2.1 Playing Back by Date The search sources include From R/W HDD and redundancy HDD. The search sources include From R/W HDD and redundancy HDD. The redundancy HDD is supported only when there is a redundancy HDD on the Device. For details about redundancy HDD operations, see “4.6.4.
File list Set up the start time of the queried file list, and then click . The queried recording files are displayed. Record type: R indicates regular record; A indicates alarm; M indicates motion detection. Double-click the recorded video file to start playing back recorded video. Select a recorded video, and then click video file will not be covered. Click to lock the video file. The locked to view the locked video file and unlock it. 4.4.2.
Click . The system is playing back snapshots according to the configured interval. 4.4.2.3.2 In the search type list, select PIC. Select where you want to search the snapshots, and enter the interval time. The search sources include From R/W HDD and redundancy HDD. The redundancy HDD is supported only when there is a redundancy HDD on the Device. For details about redundancy HDD operations, see “4.6.4.2Managing Storage Device.” From R/W HDD: Play back snapshots from local HDD of the Device.
Preconditions Make sure the external storage device such as USB flash disk is connected to the Device. Steps Select Main Menu > BACKUP. The BACKUP interface is displayed. See Figure 4-30. The detected external storage devices are displayed with the corresponding space information and status. NOTE Select the external storage device, and then click Format to clear the data in the external storage device.
List of recorded video files Select the file that you want to download, and then click Backup. The progress and remaining time are displayed by a progress bar during backup. Click OK to complete backup. You can view the backup files on PC. NOTE You can view the backup files on PC. The file format is “Channel number_Record Type_Time.dav.” The format for time is “year/month/date/hour/minute/second.” Alarm Configuration 4.5.
Motion detection Select the channel number, and click to enable the motion detection for the channel. Configure jitter removal time and enable delay motion detection. If there are multiple alarms during this period, the system records only one alarm event. After the delay motion detection is enabled, motion detection begins after a period of time. Set detecting area 1) Next to Region, click Setup. The Area interface is displayed, see Figure 4-33.
Area interface 2) Select a region and set up the region name. The higher the sensitivity value is, the easier the motion detection is triggered; the lower the threshold is, the easier the motion detection is triggered. By default, the entire video images are covered by dynamic detection. NOTE Each color represents a certain region, you can set different motion detection areas for each region.
Linkage Reference chapters Description Alarm Output When an alarm is triggered, the system starts recording by linking the alarm output device. After an alarm ends, the alarm output stops after an extended time period according to the configured Alarm Delay. See4.5.1.3Output for details. Snapshot When an alarm is triggered, the system starts snapshot by linking the channel. See4.5.1.4Snapshot for details.
Record Plan Select the channel number for linking recording. Configure the recording time period and the recording type. 1) Click .corresponding to the week. The Time Period interface is displayed. See Figure 4-35. Time Period 2) Select the record type and weekday, and enter the recording period. Configure the alarm type as needed, and select Motion Detection or Alarm. ◇ To configure video detection linking with alarm recording (such as motion detection), select Motion Detection.
Click OK. The recording schedule appears on the Record interface to view the configured recording schedule directly. Click Apply. 3) 4.5.1.2.2 Enabling Automatic Recording After automatic recording on the recording channel is enabled, the recording channel starts alarm linking with recording. Right-click Manual > Record on the homepage. The Record interface is displayed. Enable automatic recording on the recording channel. See Figure 4-36. Record Click Apply. 4.5.1.2.
Record Channel Select the record channel. Support multi-selection. One highlighted in blue means it is selected. Configure Delay. 4.5.1.2.4 Result Verification Take the configuration of motion detection on alarm linking with video recording as an example. When an alarm is triggered, click or click the record time period on the time shaft to play back alarm video after type, time, channel number, and record type are configured on the Playback interface. 4.5.1.
Settings Click to enable the alarm output. Select a port for alarm output, and click OK. Support multi-selection. One highlighted in blue means it is selected. Configure alarm output delay. Result Verification When an alarm is triggered, the alarm output device gives an alarm, such as beep, light flashing, etc. 4.5.1.4 Linking Snapshot After snapshot is linked, the system starts snapshot by linking the channel when an alarm is triggered. 4.5.1.4.
Snapshot Select the channel number for linking snapshot. Configure time period and type for snapshot. 1) Click .corresponding to the week. The Time Period interface is displayed. See Figure 4-40. Time Period 2) Select the snapshot type and weekday, and enter the period for taking snapshot. Configure the alarm type as needed, and select Motion Detection or Alarm. ◇ To configure video detection linking with alarm video recording (such as motion detection), select Motion Detection.
Click OK. Snapshot schedule appears on the Snapshot interface to view the configured snapshot schedule directly. Click Apply. 3) 4.5.1.4.2 Enabling Automatic Snapshot After automatic snapshot on channel is enabled, the channel starts alarm linking with snapshot. Right-click Manual > Record on the homepage. The Record interface is displayed. Enable the automatic snapshot on channel. See Figure 4-41. Record Click Apply. 4.5.1.4.
Snapshot Select the snapshot channel. Support multi-selection. One highlighted in blue means it is selected. 4.5.1.4.4 Result Verification When an alarm is triggered, enter the local Video Search interface. After search condition is configured, click the snapshot time period on the time shaft to play alarm snapshots back. 4.5.1.5 Linking Tour After tour is linked, a tour of the selected channels is displayed on the local interface of the Device when an alarm is triggered.
Tour Select the channel for tour. Support multi-selection. One highlighted in blue means it is selected. Result Verification When an alarm is triggered, a tour of the selected channels is displayed on the local interface in a form of single-window. After an alarm ends, the local interface returns to the window before alarm. 4.5.1.6 Linking Message Show When an alarm is triggered, alarm message is displayed on the local interface after message display is linked.
Show Message Result Verification Take the configuration of motion detection on alarm linking with screen output as an example. When an alarm is triggered, the Alarm Status interface is displayed on the local interface of the Device. 4.5.1.7 Linking Email Sending After Email sending is linked, the system sends an alarm email to a designated recipient when an alarm is triggered. 4.5.1.7.
Email Click to enable email function. Configure TCP/IP parameters. For details, see Table 4-13. Table 4-13 Email setting parameters description Name Description SMTP Server Configure the address of SMTP (Simple Mail Transfer Protocol) server. Port Enter the port value of SMTP server. Username Password Receiver Sender Email Enter the user name and password of SMTP server.
Name Description Health Enable The system sends test mail to check if the connection is successfully set up Select the Health Enable check box, and then enter the interval. The system can send a test email to check the connection after the specified interval NOTE The value ranges from 30 minutes to 1440 minutes Click Apply. Click Test to test if emails can be sent out and received as intended after configuration. If the configuration is correct, you would receive test email. 4.5.1.7.
Buzzer Result Verification When an alarm is triggered, the Device beeps. 4.5.1.9 Linking Log After log is linked, alarm message is recorded in the system log when an alarm is triggered. Steps Enter the alarm configuration interface, and select System Log. See Figure 4-48.
System log Result Verification When an alarm is triggered, select Alarm > Alarm Information, and configure type, start time, end time, and researchable alarm log information. See Figure 4-49. Alarm Log 4.5.2 Configuring Video Detection Settings Check whether any change with a certain level occurs or not by analyzing video images. If a change with a certain level occurs in an image (such as object moving, fuzzy image, etc.), the system starts alarm linkage.
4.5.2.1 Video Detection After the motion detection is configured, the system starts alarm linkage when a mobile object occurs in the monitoring screen and the moving speed reaches the preset sensitivity. See4.5.1Alarmfor details. 4.5.2.2 Configuring Tampering After tampering is configured, the system starts alarm linkage when the monitoring screen is blocked by an object, causing the monitoring screen outputting single-color images. In the main menu, select Alarm > Detection > Tampering.
system starts alarm linkage after the local alarm is configured. IPC offline alarm: When network connecting the Device with IPC is off, the system starts alarm linkage. In the main menu, select Alarm > Alarm Input. The Alarm Input interface is displayed. See Figure 4-51. Alarm Input Click each alarm event tab, and enable the alarm input or channel. Local alarm: The local alarm is enabled by default. Select alarm input, and configure the alarm name.
Abnormality Click each abnormal event bar, and select Event Type. Hard Disk: Configure abnormal event alarm detection for hard disk, including No HDD, HDD Error, HDD No Space. User: Configure abnormal event alarm detection for illegal login. Device: Configure abnormal event alarm detection for device, including low battery, temperature too high, rollover, collision, over speed and low speed. Enable abnormal event alarm detection.
Name Description Accumulator voltage In the Battery Voltage boxes, enter the minimum percentage of supply voltage and supply voltage to the device from the vehicle. When the vehicle is in ACC Off, the voltage supplied to the device is lower than the preset minimum percentage, the system generates an alarm Max Speed If Over Speed is selected, configure this parameter The upper limit of vehicle speed.
Stop: After the alarm linkage is configured, no matter whether there is an alarm event occurs, the corresponding alarm output port never generate alarm. Click Apply. View status of all alarm output ports under Status. 4.5.6 Searching Alarm Log Search alarm log within a time period. In the main menu, select Alarm > Alarm Information. The Alarm Information interface is displayed. Configure type, start time and end time. Click Search. The alarm information satisfying the searching conditions are displayed.
4.6.1.1 Configuring Encode Parameters 4.6.1.1.1 Configuring Video Streaming You can set up some video stream parameters, including Stream Type, Encode Mode, Resolution, and more depending on the actual network bandwidth. In the main menu, select Camera > Encode Setting > Encode. The Video Stream screen appears. See Figure 4-55. Video Stream Select channel, and configure parameters. For details, see Table 4-15.
Name Stream Ctrl Description You can select bit rate type CBR: Constant Bit Rate, which changes around the configured value VBR: Variable Bit Rate, which changes along with environment NOTE It is recommended to select CBR when there might be only small changes in the monitoring environment, and select VBR when there might be big changes in the monitoring environment Bit Rate Configure the encode value for main stream and sub stream When CBR is selected, select the bit rate according to the reference bit
Snapshot Stream Configure TCP/IP parameters. For details, see Table 4-16. Table 4-16 Snapshot setting parameters description Name Description Channel Select the corresponding channel number. Snap Mode Includes timing and events Timing: Take a snapshot within the configured period Event: Take a snapshot when there is an alarm triggered, such as local alarm, video detection and abnormality. Size Select a resolution for the captured image.
Superposition Coding Select Superposition Coding or Preview Overlay according to overlay information. In the Superposition Coding interface, select channel to overlay the time display, channel display, and license no. display in video images. You can customize the channel display. In the Preview Overlay interface, overlay channel display. Click Apply. 4.6.1.3 Configuring PoE Review the connection status of the PoE port and reset the camera. Select Camera > PoE in the main menu.
PoE 4.6.2 Network Parameters Configuration 4.6.2.1 Connection Setting Set the port for simultaneous access to the device through Clients ( including WEB clients, platform clients, mobile phone clients, etc.). Select Main Menu > NETWORK > CONNECTION SETTING. The Connection Setting interface is displayed. See Figure 4-59. Port Configure the port parameters of the device. For details, see Table 4-17.
NOTE The revised settings take effect after reboot. Proceed with caution. Table 4-17 Connection setting parameters description Name Description TCP Port Transmission Control Protocol port, the value is 37777 by default UDP Port User Datagram Protocol. The default value setting is 37778. You can enter the value according to your needs HTTP Port Hyper Text Transfer Protocol port. The default setting is 80.
4.6.2.2.1 Setting 3G Parameters Preconditions Make sure the Device is equipped with 3G module and inserted with SIM card from the Communication Operator. The dial number, user name, and password have been obtained from the Communication Operator. Steps Select Main Menu > NETWORK > 3G > 3G. The 3G interface is displayed. See Figure 4-63. 3G Select 3G Network, click to enable the network. This function is enabled by default. Configure TCP/IP parameters. For details, see Table 4-18.
Name Description AUTH Includes PAP, CHAP, and NO_AUTH protocols. The system automatically recognizes and displays the enabled protocol Dial Number Enter the dial number provided from the Communication Operator Username This parameter needs to be set up when the authentication mode is PAP or CHAP The system automatically recognizes the username and password Password Click Apply. After access is succeeded, the obtained IP address is displayed. 4.6.2.2.
Data usage 4.6.2.3 Configuring Switch Settings After setting up the SWITCH, the device automatically allocates IP addresses to the IPC directly connected to the PoE port of the device. CAUTION By default, the Switch Settings check box is enabled. The network segment is 10.1.1.1. It is recommended to keep the default setting. If the IP camera is from the third party, it must support the Onvif protocol and has enabled DHCP. In the main menu, select SYSTEM SETUP > NETWORK > SWITCH.
Switch settings Enter the IP address, subnet mask, and gateway. NOTE The IP address of Switch cannot be in the same network segment with the IP address of Device. It is recommended to use the default IP address. Click Apply. Instructions for PoE Connection For the PoE connection instructions, see Table 4-19. Table 4-19 PoE instructions Operation Description The device automatically connects to the IPC managed through the PoE port After connecting, the Device configures an IP address to the IP camera.
4.6.2.4 Configuring Network Testing Settings You can test the network status and load. 4.6.2.4.1 Testing Network Status You can test the network status and view the average delay and packet loss rate. In the main menu, select Info > Network > Net Test The NET TEST interface is displayed. See Figure 4-67. Net test In the Destination IP box, enter the IP address, and then click Test. After testing is completed, the test result is displayed.
Net load Click the network that you want to view. The data receiving speed and sending speed information are displayed. NOTE By default, the network load of eht0 is displayed. The green line represents data sending speed, and the red line represents data receiving speed. 4.6.3 Configuring platform 4.6.3.
Auto Registration Click to enable automatic registration. Configure TCP/IP parameters. For details, see Table 4-20. Table 4-20 Auto Registration descriptions Name Description No. Number automatically registered Address In the Server IP box, enter the IP address or domain name of the server to register Port The port for auto-registration Sub-device ID Unique ID for identifying the device.
Preconditions The device is connected to the Internet. DMSS Client is downloaded and installed on you mobile phone. Steps Select PLATFORM > P2P The P2P interface is displayed, see Figure 4-70. P2P Click to enable P2P function. Use DMSS Client to scan the QR code under Device SN to add the device to DMSS Client. CAUTION Scan the QR code on the actual interface of Device. Click OK. After configuration is complete, the Status box shows Online, meaning the P2P registration is successful.
1) Click and then select Device Manager. The Device Manager interface is displayed. 2) Click , initialize the device as needed and follow on-screen instructions to connect the device. To do so, you can scan the device label or the serial number QR code of the device on the device page. After scanning, the device is added. The serial number of the device is displayed in Serial Number section. To review the monitoring image of the device, click Start Preview. 4.6.4 Setting Device Storage 4.6.4.
You can set up the HDD as the read/write disk and redundancy HDD in the Type column. Read/Write: Read HDD data and save data to HDD. Redundancy HDD: If more than two HDDs are connected to the device or SD card, one HDD can be set to the redundancy HDD for recording backup. Select the HDD and click Formatting to clear all data from the HDD. Proceed with caution. Disk management 4.6.4.3 Setting FTP storage Back up recorded videos and images to the preset FTP (File Transfer Protocol) server for storage.
FTP Select Enable to enable FTP upload. The system selects SFTP by default. It is recommended to keep this default setting. When selecting FTP, the system gives a risk prompt. Select OK or Cancel based on your needs. Configure TCP/IP parameters. For details, see Table 4-21.
Name Description Image Upload Interval When the Snap Mode is Regular, the image upload method should be determined according to the upload interval and snapshot interval. If this interval is longer than snapshot interval, the system uploads the most recent snapshot. For example, if the upload interval is 5 seconds, and snapshot interval is 2 seconds per snapshot, then an upload command is issued every 5 seconds to upload the following picture captured.
List of video recordings S.M.A.R.T information 4.6.5 Setting user info User management of the device adopts two levels: user and user group. You can manage the basic information of users and user groups. To manage account easily, it is recommended to give lower authority to the common user account than the advanced user account Authority In order to ensure the safety of the device, operations in the ACCOUNT interface (such as adding users, deleting users, etc.
When operating in the ACCOUNT interface, if the ACCOUNT interface is not closed after the login password is correctly entered once, other operations can be directly performed. If you re-enter the ACCOUNT interface after closing it, you need to enter the login password again. Follow the interface prompts. 4.6.5.1 Setting up user group In the actual use scenario, users accessing the device may have different permissions.
Add group Configure TCP/IP parameters. For details, see Table 4-22. Table 4-22 Description of group parameters Name Description Group name Setting up group name The group name can be set to a maximum of 64 characters and may contain letters, numbers and special symbols (including “_”, “@”, “.”). Remarks Setting up note info. Click the System, Playback or Monitor tabs respectively to set user group permissions. TIPS Select All to select all permissions under this category. Click OK.
Function Operation Click to delete the group. Delete group You can delete a group only if there is no user under the group. The groups of Admin and User cannot be deleted. 4.6.5.2 Setting up system user The system user is used to access and manage the device, and the system default administrator is admin. When adding different users, ensure that users can only access resources within their own permissions. Steps Select Main Menu > SYSTEM > ACCOUNT > User Setup.
Add User. Configure TCP/IP parameters. For details, see Table 4-24. Table 4-24 Description of user parameters Name Description Username Setting up user name. The user name can be set to a maximum of 64 characters and may contain letters, numbers and special symbols (including “_”, “@”, “.”). Setting up user password and confirming it. The new password can be set from 8 characters through 32 characters and may contain two or more types from number, letter and special characters (excluding ' " ; : &).
Function Operation Click Editing user info to modify information such as group, user password and reserved mobile phone. NOTE Modification of reserved mobile phones is only available for admin account. Click Delete User to delete the user. NOTE The admin account cannot be deleted. To delete online users, you need to log into the local interface to block online users first. 4.6.5.3 Online User Select Main Menu > STATUS > NETWORK > Online User, the Online User interface is displayed.
System service Configure TCP/IP parameters. For details, see Table 4-26. Table 4-26 Description of system service parameters Name Description Reset Password After this function is enabled, you can reset a new login password of the admin account if the old one is lost. The system enables this function by default. NOTE When the Password Reset function is disabled, the password can only be reset through the password protection question in the local interface.
4.6.7.1 Configuring resolution In the main menu, select System Management > Display Output > Display Output. The Display Output interface is displayed. See Figure 4-82. Display output Select resolution. Click Apply. 4.6.7.2 Configuring tour parameters In the main menu, select System Management > Display Output > Tour. The Tour interface is displayed, see Figure 4-83.
Tour Click and enable the tour function. Set up the interval time. Select image split and then the touring channel accordingly. Click Add to customize the touring sequence. Select the channel combination; click Modify to modify the touring channels and touring sequence. Select the check box of any channel group, and then click Delete to delete the channel group. Select the check box of any channel group, and then click Up or Down to adjust the position of the channel group. Click Apply. 4.6.7.
TV adjustment Drag the slider to adjust the TV brightness and the upper, lower, left and right margin. Click Apply. 4.6.7.4 Configuring Video Mirror settings In the main menu, select System Management > Display Output > Video Mirror. The Video Mirror interface is displayed. See Figure 4-85. Video Mirror Select the channel and set up the mirror mode. You can select left/right mirror and up/down mirror. Click Apply.
4.6.8 Configuring RS-232 port function After the RS-232 function is set, the device can be connected to other devices through the serial port for tuning and operation. Select Main Menu > OTHERS > RS232. The RS232 settings interface is displayed, see Figure 4-86. RS232 settings Select the MainCom or Extended Serial Port tab according to the serial port function. Select the MainCom tab when using a normal serial port or connecting a car lamp box. When RS485 is used, select the Extended Serial Port tab.
4.6.9 Configuring Vehicle Settings 4.6.9.1 Configuring Speed Select Main Menu > OTHERS > VEHICLE > SPEED. The SPEED interface is displayed. See Figure 4-87. Speed Sets up DBHA parameters. See Table 4-28 for details.
The default values displayed on the interface can deviate from the actual installation position. Without correction, the vehicle running as intended can also trigger an alarm. Select Main Menu > OTHERS > VEHICLE > Gyro. The Gyro interface is displayed, see Figure 4-88. On this interface, you can view the acceleration, angular velocity and temperature of the vehicle where the device is located. Click Reset to correct the acceleration and angular velocity of the vehicle. Gyro Sets up DBHA parameters.
Position report (device auto) 2. Configure TCP/IP parameters. For details, see Table 4-30.
Position report (platform schedule) Click Apply. In the Resume Upload after Offline area, you can view the resumed upload status after offline and resumed upload details. Click DATA FORMAT to clear the resumed upload record. System Update 4.7.1 Viewing system version Check the device model, software version and other information. Select Main Menu > STATUS > VERSION. The VERSION interface is displayed. See Figure 4-91.
Version details 4.7.2 Upgrading System Upgrade the system version by importing *.bin files. Preconditions The correct version of the upgrade file has been obtained. An external storage device (USB flash drive etc.) with upgrade files has been inserted into the device. Steps Select Main Menu > SYSTEM > UPGRADE. The Upgrade interface is displayed. See Figure 4-92.
System update (1) Select an upgrade type to start upgrade. Click System Upgrade to update the system. Click MCU Update to update the MCU. The Upgrade interface is displayed. See Figure 4-93. System update (2) Select the upgrade file, and then click Start. The system starts upgrading.
System Maintenance 4.8.1 Requirement for Maintenance For the system’s good and safe running, it’s recommended to manage and maintain the system, backup files in the following methods. Check surveillance images regularly. Clear not frequently-used user and user group regularly. Modify your password every 3 months. Check your system log regularly. Handle problems asap. Backup your configuration of system regularly. Reboot this device regularly. Upgrade firmwares regularly. 4.8.
Modify User Click after Modify Password to enable the function of modifying the password. Type old password, new password. Then type your new password again to confirm it. NOTE The new password can be set from 8 characters through 32 characters and contains at least two types from number, letter and special characters (excluding ' " ; : Please set a high security password according to the prompt of password strength. The user with Accout authority can also modiy the password of other users.
Steps Enter the login interface. If you configured unlock pattern, the unlock pattern interface is displayed. Click Forgot Unlock Pattern, the password login interface is displayed. See Figure 4-96. If you did not configure unlock pattern, the password login interface is displayed. See Figure 4-96. NOTE On the unlock pattern login interface, click Switch User to login; or on the password login interface, in the User Name list, select another user to login. Login Click . The Message interface appears.
If the reserved phone number was set, the interface is displayed. If no reserved phone number was set, set the reserved phone number according to system instructions. Then click Next. Reset the login password. Reset by QR code In the Reset Type list, select QR Code, and then follow the onscreen instructions to get the security code in your reserved email address. CAUTION Scan the QR code on the actual interface of Device. You can get the security code twice by scanning the same QR code.
Log List 4.8.4 Review status information 4.8.4.1 Review running status You can review the running status of the device. Select Information > Running Status. The system displays the ACC status, voltage, temperature, and more. See Figure 4-99.
4.8.4.2 Viewing Satellite Info You can view the satellite positioning information such as module state, positioning status, antenna status, latitude and longitude, and search results. Select Main Menu > Status Information > SATELLITE INFO. The SATELLITE INFO interface is displayed. See Figure 4-100. Satellite information 4.8.4.3 Viewing alarm status You can view the alarm status. The alarms of each channel are displayed in the alarm interface. Select Main Menu > STATUS > ALARM.
Alarm 4.8.4.4 Viewing Data Rate Information You can view the real-time data stream rate and diagram of data rate changes. Select Main Menu > STATUS > BPS. The BPS interface is displayed. See Figure 4-102. Viewing Data Rate Information 4.8.5 Auto Maintain You can configure the automatic maintenance settings such as auto reboot, auto booting up or shutdown, and delay for auto shutdown.
4.8.5.1 Reboot system After configuring auto reboot, when the Device is working, it reboots according to the schedule. Select Main Menu > SYSTEM > SYSTEM MAINTENANCE. The SYSTEM MAINTENANCE interface is displayed, see Figure 4-103. Auto Maintain By default, the system never reboots automatically. Select the auto reboot time according to your need. Click OK. The system auto reboots at the specified time. 4.8.5.
immediately. When the ACC of the vehicle is off after booting up, the device will be shut down according to the preset automatic shutdown delay time. Select Main Menu > SYSTEM > SYSTEM MAINTENANCE. The SYSTEM MAINTENANCE interface is displayed. In the Auto Boot up area, select Valid, and then enter the specific time. Click OK. 4.8.5.4 Configuring auto shutdown system After configuring auto shutdown, the Device automatically shuts down according to the ACC power off time and auto boot up setting.
IMP/EXP Select the backup path and click Export. The system will pop up a message in case of success. Click OK to complete backup. 4.8.6.2 Restoring Configurations Select Main Menu > SYSTEM > CONFIGURE BACKUP. The CONFIGURE BACKUP interface is displayed. If the external storage device is connected before the interface is entered, the system will automatically identify the information of the external storage device, as shown in Figure 4-105.
Select a file and click Import. After the import is completed, the system prompts that the settings will take effect after reboot. Click OK. The system starts rebooting. 4.8.7 Restored to the Default Settings You can restore the system to default configurations or the factory default. Only the user with the default&upgrade authorities can do this. CAUTION The corresponding functions will be restored to the factory settings, and your current configurations will be lost. Proceed with caution.
4.8.8 Network packet capturing You can back up the network packet to the external storage device. These data can be provided to the developers or engineers to analyze the network usage status. Preconditions Make sure the external storage device such as USB flash disk is connected to the Device. Steps Select Main Menu > INFO > NETWORK > NET TEST. Test NET TEST interface is displayed. Connect the external storage device to the USB port of the Device, and then click Refresh.
Click Manual Reboot and the device is rebooted immediately. Click Logout User to log out the currently logged-in user.
5 Web Operations You can access and operate the Device from web interface on PC client. The web interface comes with the functions such as real-time preview, recording query, settings alarm, configuring system, PTZ control and monitoring screen. NOTE Several browsers are supported, including Chrome, Firefox, and IE. Initializing Device When you are opening the device for the first time or you have allowed your system to be restored the factory settings, you need to initialize the device.
Password protection Select the reset type based on your needs. It is recommended to enable the two types as follows. Check the Phone No. box, and then enter the phone number in the box. Check the Security Question box, select the question and enter the corresponding answer. Click Next. The completion interface is displayed. See Figure 5-3. Complete Click Save. Logging into the Device You can login to and then configure the device. Open the browser, enter the Device IP address, and then press Enter.
Web login interface Enter Username and Password and click Login. The PREVIEW interface is displayed. See Figure 5-5. Clicking Exit can log out. NOTE Install the plugin as prompted by the system for initial login. In the upper left corner, the main stream and substream are differentiated by the tab. For admin account, if you forget password, click Forgot Password to find back the password. For details, see 5.5.5.3.3Reset Password. Preview interface Quick configuring 5.3.
Preconditions Make sure the Device is connected to the network properly. Steps Select Setup > Network > TCP/IP. The system displays the TCP/IP interface, as shown in Figure 5-6. TCP/IP Configure TCP/IP parameters. For details, see Table 5-1. Table 5-1 TCP/IP parameter description Name Description Select IPv4 or IPv6.
Name Description Default gateway NOTE IP address and gateway must be in the same network segment Preferred DNS IP address of the preferred DNS Alternate DNS IP address of the alternate DNS MTU Displays the MTU value of the Ethernet card. The default setting is 1500 bytes and cannot be changed Click Save. 5.3.2 Configuring General Settings You can configure the basic settings, including time and date settings. 5.3.2.
Name Description Disk full Configure the settings for the situation when HDD is full, including stop and overlap Stop: When the HDD is full and there is no extra free disk, the recording stops Overlap: When the HDD is full and there is no extra free disk, the new recorded video overlaps the old videos Packaging manner Enter the length of time for packaging each video file.
Name Description Time zone In the Timing Mode list, if NTP is selected, configure this parameter Configure the Time zone that the device is at System Time Displays the current system date and time Sync PC Click Sync PC to sync the system time with the PC from where you login the web interface DST DST type Begin time End time The DST is applied in some countries or regions. Select the DST check box if it is applied where the Device is located 19. Select the DST check box 20.
Remote device Click Device Search. The searched devices are displayed. Select the Uninitialized check box. The uninitialized devices are displayed. Select the check box the uninitialized device, and then click Initialize. The password setting interface is displayed. See Figure 5-10. Password setting Configure the password by either of the following two ways. Using current device password and phone info.
Set a password. 2) In the New Password box, enter the new password and enter it again in the Confirm Password box. Click Next. The password protection interface is displayed. See Figure 5-12. Password protection 3) Set up password protection. ◇ Select the Phone No. check box, and then enter the phone number. Click Next. ◇ Click Skip if you do not want to set up password protection. The Device starts initializing Device. After initialization is completed, see Figure 5-13.
Initialization completed Click Save. 5.3.3.2 Adding a Remote Device You can add a remote device manually or by search. Select Setup > CAMERA > REMOTE. The REMOTE interface is displayed. Adding a remote device. Search and Add 1. Click Device Search, the searched devices are displayed. 2. Double-click on an IP address or select the check box of a device, and then click Add. The device displays in the added device area. Manual Add 1. Click Manual Add. The Manual Add interface is displayed.
Manual Add 2. Configure TCP/IP parameters. For details, see Table 5-4. NOTE The parameters might be different depending on the model you purchased. Table 5-4 Manual add parameters description Name Description Manufacturer Select a manufacturer according to the actual situation. Parameters might vary by manufacture. Follow specific parameters on the interface IP address Enter the IP address of remote device TCP Port TCP service port. The default setting is 37777.
To delete an added device, select it, and then click Delete; to modify the information of an added device, click or double-click the device. 5.3.4 Configuring Record Settings The record mode is consisted of manual mode and auto mode. You can also enable or disable the snapshot function. Auto: The recording starts automatically according to the record type and recording time as configured in the recording schedule. Manual: Keep general recording for 24 hours for the selected channel.
Name Description Auto/Manual/Stop Select the recording mode, including Manual, Auto, and Stop Manual: Top priority. When the Manual check box is selected, the system keeps general recording for 24 hours for the corresponding channel Auto: The system starts recording according to the record type (such as general alarm, motion detect, and system alarm) and recording time Stop: Do not record Enable/Stop Enable or disable the scheduled snapshot for the corresponding channels Click Save. 5.3.
Record Plan Configure TCP/IP parameters. For details, see Table 5-6. Table 5-6 Record schedule parameters description Name Description Channel Select a channel to configure the corresponding recording schedule. To configure the same setting for all channels, select All Pre-record Start recording for 0 seconds to 30 seconds before the alarm event occurs. If you enter 0 seconds, there will be no pre-recording Configure the recording time period. 1) Click Setup corresponding to the week.
example, if the alarm type is MD, select Enable Channel, and select the recording channel. 3) Click Save. The recording schedule appears on the Record interface to view the configured recording schedule directly. Click Save. NOTE Click Copy to and you can copy the settings to other channels. 5.3.5.2 Configure snapshot schedule You can configure the storage schedule for taking the snapshot. Preconditions The Snapshot is enabled for the corresponding channel. For details, see “5.3.
Settings 2) 3) Select the snapshot type and weekday, and enter the period for taking snapshot. Click Save. Snapshot schedule appears on the Snapshot interface to view the configured snapshot schedule directly. Click Save. Common operations 5.4.1 Live View After you logged in the web interface, the PREVIEW interface is displayed. See Figure 5-20. Preview interface Table 5-7 Preview interface parameters description No.
No. Name Description 2 Real-time monitoring channels See "4.1.2Real-time Monitoring Channels" for specific steps. 3 Start talk See "4.1.3Voice intercom" for specific steps. Click Instant Record and the recording type switches to Manual, when 4 Instant Record the icon turns to ; click Instant Record again to switch the record type back to Auto NOTE This function is only supported by main stream. 5 6 Local playback Window function operations Plays back the video file (.dav) stored on the PC.
Video monitoring screen Table 5-8 Video monitoring window parameters description No. Parameter Description 1–4 Device information Displays the IP address, channel number, bit stream, and stream type (M represents main stream, S represents sub stream) Area zoom in Click this icon and then hold down the left mouse button to select the area you want to enlarge. The area is enlarged.
Bit rate 5.4.1.3 Voice intercom You can do the two-way voice talk between the Device and Client. Voice intercom Click Start Talk to enable the voice talk between the Device and Client. Click the drop-down list to select the voice talk mode. Available options include: DEFAULT, PCM, G711a, and G711u. After enabling voice talk, the Start Talk icon turns to . Click Stop Talk if you want to end the talk. 5.4.1.
PTZ Console 5.4.1.4.2 PTZ You can configure scan, preset, tour, pattern, and auxiliary functions.
Parameter Description Scan After setting up scan, the camera automatically scans the configured left border and right border 23. In the PTZ Setup list, select Scan, and then click Setup. Two buttons of Set the left border and Set the right border are displayed. 24. Through the PTZ control panel, move the camera to the left border that you want and click Set the left border; move the camera to the right border that you want and click Set the right border. Configuration finished. 25.
Parameter Description Wiper Controls the screen wiper of external device through RS-485 command. To use this function, make sure it is supported on the external device. In the PTZ Setup list, Click Screen Wiper. Click On to turn on the screen wiper, and click Off to turn off the screen wiper. Clear fog Controls the warming-up module of external device through RS-485 command. To use this function, make sure it is supported on the external device In the PTZ Setup list, Click Clear fog.
Parameter Description Save The Save button provides the following functions If there is sub-menu for an item, click Save to enter the sub-menu Move the pointer to Return, and then click Save to return to the higher level menu Move the pointer to Exit, and then click Save to exit the menu Click On. The OSD menu is displayed on the monitoring screen.
Image setup Configure TCP/IP parameters. For details, see Table 5-15. Table 5-12 Image setting parameters description Name Description Brightness Adjusts the image brightness. The bigger the value is, the brighter the image will become Contrast Adjusts the contrast of the images. The bigger the value is, the more obvious the contrast between the light area and dark area will become Saturation Adjusts the color darkness. Adjust the saturation according to the actual situation.
5.4.1.6 Multi-channel preview After the multi-channel preview is enabled, the output image is compressed to combine multiple channels in the local interface to one channel. Then you can view multiple channels from remote access, and save much of the network transmission bandwidth. Select a channel, and then select the split mode from . Then you can view the multiple channel views in one channel. See Figure 5-33. Multi-channel preview 5.4.
Playback Table 5-13 Function bar description No. Function Description 1 Playback Controls Bar For detailed information about control buttons, see “5.4.2.
No. Function Description Select the screen split layout and enter the corresponding channel number Screen split layout for playback 8 Click to display in full screen. Press ESC to exit full screen 9 File list You can download recorded video by file type or time, and verify the completeness 10 Video editing Capture and save certain video section See "5.4.2.3Clipping" for specific steps. 5.4.2.1 Playback Controls Bar See detailed description in Table 5-17.
5.4.2.2.1 Playing Back Recorded Video by date Select the month and year that you want to search, and then select the screen split layout and enter the corresponding channel number. Select a date with recorded video files, click on the window channel to select a playback channel, and then select the record type. Record Type Click to start playing back recorded video. 5.4.2.2.
Set up the start time of the queried file list, and then click . The queried recording files are displayed. Double-click the recorded video file to start playing back recorded video. NOTE Select the video files, and then click Download. The recorded files default storage path is C:\RecordDownload. You can modify this path if needed. Click More to search and download more recorded video files by file type or time. You can also verify whether the watermark is falsified. See "5.4.2.
Download by file Select channel, type, start time, and end time. Then click Search. The searched files are displayed in the table. NOTE The system supports searching the recorded files through the record type (general, motion detect, or alarm), and supports searching the snapshots. Select the file that you want to download, and then click Download to Local. The Download to Local interface is displayed. Select the record type and save path.
Select the Record Format and Path. Downloaded video formats supported by the system include DVA and MP4. Choose according to the actual situation. Click Save. The system indicates the downloading progress and pops up a message after completed. 5.4.2.4.3 Watermark You can also verify whether the watermark is falsified. Click the Watermark tab. The Watermark interface is displayed. See Figure 5-41. Watermark Click Local File and select a file that you want to verify. Click Verify.
5.4.3 Configuring Alarm Events Settings You can select alarm type as needed, when the selected alarms are triggered, the system would record detailed alarm information at the right side of the interface. NOTE Function of different devices might vary, and the actual product shall prevail. 5.4.3.1 Alarm types For the alarm types and conditions that can trigger the alarm events, see Table 5-18.
Alarm Select alarm type. Select prompt, and the system prompts and records alarm information as needed. If you are not at the Alarm interface when the selected alarm is triggered, there will be a displayed on the Alarm tab and the alarm information will be recorded. Click the Alarm tab, and the sign disappears. If you are at the Alarm interface when the selected alarm is triggered, there will be detailed alarm information displayed at the right side of the interface.
The Conditions interface is displayed. See Figure 5-44. Image settings Set up parameters. See Table 5-19. Click Save. Table 5-16 Image setting parameters description Name Description Configuration files Select the configuration files for the images.
Name Description Scene Mode In this mode, you can make an white object displaying itself clearly on the video image in all environments.
Video Stream Select a channel. Configure TCP/IP parameters. For details, see Table 5-20. Table 5-17 Encode setting parameters description Name Description Stream Type The stream type is permanently fixed as common and cannot be changed The record types of general, motion detect, and alarm all adopt common bit stream configuration in recording. Encode Mode Encode Mode of video Smart Code Turning on Smart Code helps compress the images more and reduce the storage space.
Name Description Image Quality This parameter can be set only when Stream Ctrl is set to BRC_VBR. Select the image quality level.
Name Description Size Image resolution of snapshots. It is the same as the resolution of the main stream and cannot be changed Quality Configures the image quality by 6 levels Interval Interval of taking snapshots Select Customized to configure the snapshot interval for manually capturing snapshots. The maximum value you can set is 3600 seconds as an interval between two snapshots Click Save. 5.5.1.2.3 Configuring Video Overlay You can configure the title of video image overlay.
5.5.1.2.4 Path You can configure the storage path of captured snapshots and recorded videos. Select SETUP > CAMERA > ENCODE > Storage Path. The Path interface is displayed, see Figure 5-48. Path Click Browse to select the save path for snapshots and records. On the PREVIEW interface, images and recordings taken by snapshot and recording are saved in the following paths by default: Default paths: C:\PictureDownload and C:\RecordDownload Click Save. 5.5.1.
offline until the total power of the camera accessed through PoE does not exceed the maximum power of the device. PoE management 5.5.2 Network Parameters Configuration Set up the network parameters of the device as needed. This includes setting up the port, , 3G parameters, Email, FTP, active registration, P2P and SWITCH. 5.5.2.1 Connection Setting Configure the maximum port numbers and values. Select Setup > Network > Connection Setting. The Connection Setting interface is displayed. See Figure 5-51.
Name Description HTTP S Port Hyper Text Transfer Protocol over Secure Socket Layer port. Select the Enable check box, and then enter the value according to your actual situation. The default setting is 443 Real Time Streaming Protocol port, leave it if the value is 554 by default.
NOTE After 3G module is connected, the module information and wireless signal are displayed; if not, click Search to search for wireless signal. Select 3G Network and Enable to open the network. This function is enabled by default. Configure TCP/IP parameters. For details, see Table 5-24. Table 5-21 3G setting parameters description Name Description NetAccess When the Device is accessed to private network, select the NetAccess check box, enter APN name and select authentication mode.
Email Select Enable to enable email. Configure TCP/IP parameters. For details, see Table 5-25. Table 5-22 Email setting parameters description Name Description SMTP Server Configure the address of SMTP (Simple Mail Transfer Protocol) server. Port Enter the port value of SMTP server. Username Password Enter the user name and password of SMTP server. Sender Sender’s email address Encryption type In the Encrypt list, select an encryption type from NONE, SSL, and TLS.
Name Description Interval This is the interval that the system sends an email for the same type of alarm event, which means, the system does not send an email upon any alarm event The interval ranges from 0 to 3600 seconds. 0 means that there is no interval NOTE This setting helps to avoid the large amount of emails caused by frequent alarm events Health Enable The system sends test mail to check if the connection is successfully set up Select the Health Enable check box, and then enter the interval.
FTP setting Select Enable to enable FTP upload. The system selects SFTP by default. It is recommended to keep this default setting. When selecting FTP, the system gives a risk prompt. Select Save or Cancel based on your needs. Configure TCP/IP parameters. For details, see Table 5-26.
Name Description File Length Enter the length of the uploaded recorded video If the entered length is less than the recorded video length, only a section of the recorded video can be uploaded If the entered length is more than the recorded video length, the whole recorded video can be uploaded If the entered length is 0, the whole recorded video will be uploaded Image Upload Interval When the Snap Mode is Regular, the image upload method should be determined according to the upload interval and snapsho
Auto Registration Select the Enable check box .(Selected by default) Configure TCP/IP parameters. For details, see Table 5-27. Table 5-24 Auto Registration descriptions Name Description Server IP In the Server IP box, enter the IP address or domain name of the server to register Port The port for auto-registration Sub-device ID Unique ID for identifying the device. When different devices register to the same server, the sub-device IDs should be different Click Save. 5.5.2.
P2P Select Enable to enable P2P. Use DMSS Client to scan the QR code under Device SN to add the device to DMSS Client. CAUTION Scan the QR code on the actual interface of Device. Click Save. After configuration is complete, the Status box shows Online, meaning the P2P registration is successful. Adding Device into Mobile Phone Client To use this function, take adding device into mobile phone client as an example. On your mobile phone, download the application.
Device management 2) Click , initialize the device as needed and follow on-screen instructions to connect the device. To do so, you can scan the device label or the serial number QR code of the device on the device page. After scanning, the device is added. The serial number of the device is displayed in Serial Number section. To review the monitoring image of the device, click Start Preview. 5.5.
5.5.3.1.1 Video Detection When the moving object appears and moves fast enough to achieve the preset sensitivity value, the system triggers an alarm and alarm linkage. Select Setup > Event Handling > Video Detection > Motion Detect. The Motion detection interface is displayed, see Figure 5-61. Motion detection Select Enable and select target channels for dynamic detection. Region configuration 1) Click Setup after Region The Setup interface pops up. See Figure 5-62.
The higher the sensitivity value is, the easier the motion detection is triggered; the lower the threshold is, the easier the motion detection is triggered. By default, the entire video images are covered by dynamic detection. NOTE Each color represents a certain region, you can set different motion detection areas for each region. 3) Drag the left button of the mouse, and select the area of the image to be detected, and set up its sensitivity and threshold value.
Name Description Select Send email, and when alarm is triggered, the system sends email to the specified mailbox Send Email NOTE Set your e-mail first before enabling this function. See 5.5.2.4 Configuring Email Settings for detailed operations System log Select the System Log check box to enable the device to record a local alarm log when an alarm event occurs Click Save. 5.5.3.1.
Alarm settings Click Local Alarm or IPC Disconnect tab respectively based on your needs. Local Alarm: The alarm signal detected by the alarm input port on the Device. IPC Disconnect: The alarm signal is generated when the IP camera is disconnected. Select the Enable check box and the target alarming channel number. Sets up DBHA parameters. See Table 5-29 for details.
Name Description Alarm Output Connect the alarm device such as light and siren to the alarm output port. Select the check box of Alarm Out to enable the alarm linkage. When an alarm event occurs, the system links the alarm device to activate alarm Latch Set a length of time during which the device continues alarm output after the alarm ends Select the Tour check box and the channels.
Abnormality Select Enable to enable the handling of corresponding abnormal events. Sets up DBHA parameters. See Table 5-30 for details.
Name Description Max Speed If Over Speed is selected, configure this parameter The upper limit of vehicle speed. When the vehicle speed exceeds this value, the system generates an alarm Min Speed If Low Speed is selected, configure this parameter The lower limit of vehicle speed. When the vehicle speed is lower than this value, the system generates an alarm Alarm Output Connect the alarm device such as light and siren to the alarm output port.
Select alarm output mode. Manual: After the alarm linkage is configured, no matter whether there is an alarm event occurs, the corresponding alarm output port keeps generating alarm. Auto: After the alarm linkage is configured, when an alarm event occurs, the corresponding alarm output port generates alarm. Stop: After the alarm linkage is configured, no matter whether there is an alarm event occurs, the corresponding alarm output port never generate alarm. Click Save.
HDD information Smart Info 5.5.5 Configuring system settings Set up system information, including the output mode, serial port parameters, and user account management. 5.5.5.1 Configuring Zero-Ch Encode Settings You can configure the parameters such as compression mode, resolution, and frame rate for Zero-Channel view. Select Setup > System > Display Output. The Zero-Ch Encode interface is displayed. See Figure 5-70.
Zero-Ch Encode Select the Enable check box to enable this function. It is enabled by default. Sets up DBHA parameters. See Table 5-31 for details. Table 5-28 Multi-channel encode parameters description Name Description Encode Mode Encode Mode of video Only H.264 encoding is available in this device Resolution The higher the video resolution, the better the image quality FPS Configure the frames per seconds for video. The larger the value is, the smoother and more vivid the image will be.
RS232 settings Sets up DBHA parameters. See Table 5-32 for details. Table 5-29 Serial port parameter description Name Description Function Select the corresponding protocol Console: Upgrades programs and debug by suing the serial interface and mini terminal software Vehicle lamp box: An external vehicle lamp box can be connected.
You can set maximum 64 users and 20 groups. The default group name by "User" and "Admin" cannot be deleted. Select the authorities to the user of a group. However, the authorities of the admin account cannot be randomly specified. Every user must belong to only one group. When selecting a group for a user, the authority that the user can be given should be no higher than the group authority.
Name Description User MAC Enter user MAC address that is allowed to login the Device Remarks Enter a description of the user Select the authorities to the user of a group. NOTE Authority The authorities of the admin account cannot be changed To manage account easily, when defining the user account authority, it is recommended to give lower authority to the common user account than the advanced user account Authority Click Save. NOTE Click to modify user information; click to delete the user.
Set up the reserved phone number. The system pops up a message to ask you whether sync to the remote devices that are accessed through the default protocol. If you select Cancel, the system does not sync to your phone and does not find the remote device connected through the default protocol. If you select Save, the system syncs to your phone to find the remote device connected through the default protocol.
Add group Enter User Group and Memo. Select authority control, including system, playback, and monitor. Click Save. NOTE Click to modify the corresponding group information; click to delete the group. 5.5.5.3.3 Reset Password You can reset the password through the reserved phone number when the password for the admin account is lost. Open a browser and login the web interface of Device. The login interface is displayed. Enter the username admin. The password setting information is displayed.
Login Interface Click Forgot password? The Reset dialog box is displayed. Click Save. The Reset the password is displayed. See Figure 5-78 Reset password (2) Follow the on-screen instructions to scan the QR code and get the security code. CAUTION Scan the QR code on the actual interface of Device. You can get the security code twice by scanning the same QR code. If you need to get the security code once again, please refresh the interface. The security code is valid for 24 hours.
New password setting In the New Password box, enter the New Password and enter it again in the Confirm Password box. The new password can be set from 8 characters through 32 characters and contains at least two types from number, letter and special characters (excluding ' " ; : Please set a high security password according to the prompt of password strength. Click Save. The system prompts successful operation. You can use the new password to login to the device. 5.5.5.3.
System service Select whether to enable password reset, CGI, or audio/video transmission encryption. After password reset is enabled, you can reset the password of the device by using your reserved phone number or through QR code when necessary. The P2P client can receive the alarm push information only after the mobile phone push is enabled and the P2P client subscribes to the alarm. After enabling CGI, the third-party platform can connect to this device through the CGI protocol.
HTTPS Click Create Server Certificate. The Create Server Certificate interface is displayed. See Figure 5-83. Create server certificate Enter the information for the parameters such as Country, State, and Location. NOTE In IP or Domain Name box, enter the same IP or domain name of the Device. Click Create. The system pops up a message after the creating is succeeded. 5.5.6.2.2 Root certificate Installation For the first time to use HTTPS after changing the PC, you need to download root certificate.
Click On. The Certificate page is displayed. See Figure 5-85. Certificate Click Install Certificate. The Certificate Import Wizard interface is displayed. See Figure 5-86.
Certificate import wizard Click Next. The Certificate Store interface is displayed. See Figure 5-87. Certificate store Click Next. The Completing the certificate import wizard interface is displayed. See Figure 5-88.
Completing the certificate import wizard certificate import wizard Click Finish. The Security Warning interface is displayed. Click Yes. The Import Completed page is displayed. The certificate has been downloaded at this point. 5.5.6.2.3 Set up HTTPS Port After creating server certificate or downloading the root certificate, you need to set up the HTTPS port. Select Setup > Network > Connection Setting. The Connection Setting interface is displayed. See Figure 5-89.
Click Save. 5.5.6.2.4 Logging through HTTPS Use HTTPS to login to the WEB interface of the device. Open the browser, enter https://xx.xx.xx.xx:port, the login interface is displayed. NOTE xx.xx.xx.xx corresponds to your Device IP address or domain name. “Port” corresponds to your HTTPS port. If the default value is 443, do not enter “:Port”. Just enter “https://xx.xx.xx.xx” to visit. 5.5.7 Configuring Vehicle Settings Set up the speed, mileage, sensor, and position report strategy of the vehicle. 5.
Name Description Speed source Select where the speed is obtained, including Pulse, Positioning Info, and Pulse&Positioning Info Pulse 1: Get the speed information from vehicle pulse system Positioning Info: Get the speed information from positioning system Pulse&Positioning Info: Get the speed data from both the pulse system and positioning system. Data from the impulse system is used first Click Save. 5.5.7.
G-SENSOR 5.5.7.3 Configuring Position Report You can configure the position report strategy to be device auto report or report per platform schedule. Select SETUP > VEHICLE> Position Report. The Position Report interface is displayed. Configure the report strategy. Auto report. 1. In the Report Strategy list, select Device Auto. The Device Auto setting interface is displayed. See Figure 5-93.
Position report (device auto) 2. Configure TCP/IP parameters. For details, see Table 5-36.
System Update 5.6.1 View system version You can view the Device version information. Select INFO > INFO > VERSION INFO. Device type, recording channel, system version and other information are displayed. 5.6.2 Upgrading System Firmwares You can import the upgrading file to upgrade the system. The upgrade file should be a .bin file. CAUTION During upgrading, do not disconnect from power and network, and reboot or shut down the Device.
Check your system log regularly. Handle problems asap. Backup your configuration of system regularly. Reboot this device regularly. Upgrade firmwares regularly. 5.7.2 System Information Review the running status, version information, system log, and satellite info of the device. 5.7.2.1 Viewing System Log You can search, view, and back up the system logs to PC. Select INFO > INFO > LOG. The Log interface is displayed. See Figure 5-96. System log Set up Start Time, End Time, and Types.
Auto Maintain Reboot system. Auto reboot: Select the time when the system auto reboots, and click SAVE. The system auto reboots at the specified time. Manual reboot: Click Manual Reboot and the device is rebooted immediately. 5.7.3.2 Configuring auto deleting old files After configuring auto deleting old files, when the Device is working, it deletes old recordings that occurred before the set schedule. CAUTION The deleted recordings cannot be restored. Use this function with caution.
5.7.3.4 Configuring auto shutdown system After configuring auto shutdown, the Device automatically shuts down according to the ACC power off time and auto boot up setting. If you have set the time for auto boot up, there are two situations when the ACC is powered off: If the system time is between the auto boot up and auto shutdown, the Device is turned off at the configured time. If the system time is before the auto boot up or after the auto shutdown, the Device is turned off immediately.
The system starts backing up configurations. 5.7.4.2 Restoring Configurations You can use the backed up configurations to quickly configure the Device and restore the device configurations. Select SETUP > SYSTEM MANAGEMENT > CONFIGURE BACKUP. The Import/Export interface is displayed, see Figure 5-100. Import/Export Click Browse, and then select the backup file you want to import. Click Config Import. The system pops up the reboot message.
the system will return to the default settings and needs to be initialized again. Proceed with caution. When there is a user operating on the local interface, the factory default settings cannot be performed until the local user log out. 5.7.5 Network packet capturing The packet data can be provided to the developers or engineers to analyze the network usage status. Preconditions The device for packet capturing is connected to an external backup device. Steps Select INFO > INFO > NETWORK SNIFFER.
6 Operating by DSS Beside from web, you can also remotely login the Device from Digital Surveillance System (DSS). For details, see the manual of DSS.
7 FAQ If your questions cannot be answer by the following contents, please contact your local service engineer or the service of our Headquarters for help. We can guide you to solve this problem. 1) Q: Disconnect the constant electricity but the device is still working. A: Possible causes: The default 5-minute shutdown delay is effective. The UPS setting provides constant power supply to the device when the lithium battery voltage is above 7V. 2) ACC is connected.
6) Q: HDD cannot be detected after rebooting. A: Possible causes: 7) HDD not installed. Poor contact between the HDD carrier and HDD. HDD is damaged. Q: Blank screen in a channel of the display A: Possible causes: 8) A camera is damaged. Replace the damaged camera. The connection wire is damaged. Replace the damaged connection wire. Q: No video output from single-channel, multiple-channel or all-channel. A: Possible causes: 9) Program is not compatible.
12) Q: The monitor has no sound. A: Possible causes: It is not an active speaker. Audio cable is damaged. Hardware malfunction. 13) Q: There is audio under monitoring state but no audio under playback state. A: Possible causes: Audio function is not enabled. The corresponding channel does not connect to the camera. Playback is not continuous when the screen is blue. 14) Q: System time is not correct. A: Possible causes: Setting is not correct.
The HDD is damaged. 19) Q: No 3G dial-up. No dial-up IP, A: Possible causes: Check if the SIM card is normal. Check if the SIM card is not in service. Check if the 3G antenna is connected as intended. Check if the 3G signals are strong enough. Try out with another SIM card. 20) Q: 3G platform is not online. A: Possible causes: Check if 3G dial-up is normal. Check if local active registration is correctly set up. Check if the sever terminal is correctly set up.
Mouse Operations NOTE The operations are based on the considerations for right-handed users. Beside the operations from the front panel and remote control, you can also use mouse to operate menus. Insert the mouse to the USB port of the Device. Operation Function If the user has not logged into the system, the password box is displayed first. During real-time monitoring, click the left mouse button to go to the main menu. When you have selected one menu item, click it to view menu content.
Operation Double-click the left mouse button Right-click Function The special operation to perform a specific action. For example, double-click the recorded video file to start playback. In multi-image, double-click a channel image to display it in full screen. Double-click again to restore the previous multi-window screen. In the real-time monitoring screen, right-click on the screen, the shortcut menu is displayed.
HDD Capacity Calculation In the first installation of the HDD, check whether the HDD is already installed. To install IDE HDD, pay attention to the jumper of the HDD. HDD capacity calculation formula: Total capacity (M) = Channel number × Demand time length (hour) × HDD capacity occupied per hour (M/hour) Recording time calculation formula: Recording time (hour) = HDD total capacity (M) HDD capacity occupied per hour (M/hour) × Channel number The Device adopts MPEG4/H.
Technical parameters MXVR4104-4 (4 identification routes) Model SYSTEM Main processor High performance industrial embedded microcontroller Operating system Embedded Linux System resources Multiplex operations, including making multichannel recording, video play back, and network operations simultaneously Operation interface User-friendly graphic menu dialog interface Input device Mouse operations, remote control operations Input method Number, English letter, symbol, expandable Chinese input
MXVR4104-4 (4 identification routes) Model Image resolution Allows connecting with four video routes, up to 1080P resolution When connecting with the analog camera, the device supports up to four routes of 960H resolution but does not support audio When connecting with IPC, this video enables the connection of two routes of 1080P digital image MXVR4104-8 (8 identification routes) Allows connecting with 8 video routes, up to 1080P resolution When connecting with the analog camera, the device supports up
MXVR4104-4 (4 identification routes) Model LCD Storage TTS broadcast Built-in trumpet provides TTS driving alert broadcasting Voice talk In voice talk, the built-in trumpet and pickup can combine to function as hand-free calls Voice intercom Allows voice talk by offering special car-mounted MIC and full-duplex talk terminals LCD 128×64 resolution, supports displaying vehicle status, speed, time, alarm information, locating information, drive information, and more Hard disk One 2.
MXVR4104-4 (4 identification routes) Model MXVR4104-8 (8 identification routes) Allows for reviewing external alarms and video loss alarms through the network Allows for downloading, storing, and playing back recording files Supports building in 3G modules that work with Telecom, Mobile, and Unicom.
MXVR4104-4 (4 identification routes) Model MXVR4104-8 (8 identification routes) Allows for adding users and groups and modifying permissions, without limiting the number of users and groups Password security protection Program upgrade Allows for modifying password. An authorized user can also set up passwords for other users.