C-series pocket thermal camera User manual Copyright © 2022 DALI TECHNOLOGY www.dali-irtech.
! Warnings, cautions and notes Definition Warning Represents a dangerous situation or act that may result in personal injury or death. Caution Represents a situation or action that could result in damage to the camera or permanent loss of data. NOTE Indicates a useful hint for the user. Important information – Please read before using the instrument Caution – As the camera uses a very sensitive thermal sensor, the lens must not be pointed directly at a strong source of radiation (e.g.
NOTE - The camera may require a 3-5 minute warm-up process before accurate readings can be taken. NOTE - Every thermal imaging camera is factory calibrated for temperature and it is recommended that this be done annually. Caution - Do not open the case or make modifications without permission, repairs should only be carried out by authorized personnel. CONTENTS ! Warnings, cautions and notes............................................................... 2 1 Introduction ........................
3.2.3 Image storage ....................................................................................................... 9 3.2.4 Image playback ..................................................................................................... 9 3.2.5 Image export ......................................................................................................... 9 3.2.6 LCD settings .........................................................................................................
4.7.7 5 System Information ........................................................................................... 21 RFQ ............................................................................................ 22 Appendix A ....................................................................................... 23 Emissivity of common materials (for reference only) ...................................................
Applications: Preventive maintenance Electric power industry: thermal state inspection of transmission lines and power equipment, fault diagnosis. Electrical system: Identifies circuit overloads in advance before they happen. Mechanical system: reduce downtime and prevent failure. Building science Roof: Detect water leakage quickly and efficiently. Building structure: Infrared energy assessment survey for commercial buildings and residential buildings.
2 Thermal camera introduction 2.1 Key function [1] power key Used for thermal imager on and off, standby and wake up. Press this switch for more than three seconds to start/close the thermal imager; Short press to enter standby/wake up (any other key can also wake up). ! Note: After power off, it is recommended to wait at least ten seconds before starting up again to ensure the safety of the thermal imager.
2.2 Interface [3] USB For data transfer and charging [4] Indicator For charging indication 3 Basic operation 3.1 The battery cannot be replaced 3.2 Quick Start 3.2.1 Obtaining thermal images Long press the power key (more than 3 seconds) until the power light turns green. About 10 seconds later, the device is initialized and enters the working state. The thermal imager is free of focusing and can make the target image clear without focusing operation. 3.2.
limit of the temperature measured by the thermal imager, the screen temperature will display > XXX℃ or < XXX℃ to prompt the user. Menu for setting temperature measurement area properties Click to select the temperature measuring point, temperature measuring area and temperature measuring line, and drag the whole temperature measuring object. You can drag the angle of the temperature measurement area by holding down any point of the four corners of the area to change the size of the area.
3.2.6 LCD settings You can adjust the screen brightness by exhaling the drop-down menu and sliding the brightness. 3.2.7 Menu Operation Description Touch screen operation: Click the icon at the bottom right of the touch screen and click each icon to perform corresponding operations.
5 User interface of working state of thermal imager [1] Temperature unit: A unit of temperature [2] Upper limit temperature: upper limit temperature value of color label. [3] Temperature color code: the color bar of the current image display [4] Lower limit temperature: lower limit temperature value of color label. [5] Temperature measurement object: you can choose point temperature measurement, line temperature measurement, region temperature measurement.
4.1.2 Drop-down menu Drop-down menu interface Drop-down menu interface: Click the corresponding icon to turn on/off WIFI, LED fill light, clear screen, lock screen. Adjust screen brightness by sliding. 4.1.3 Main menu Main menu interface Main menu interface: The ICONS of the main menu on the right are image playback, photo saving and menu button in sequence.
4.2 Temperature Measurement Mode Add or delete a temperature measurement object, including a temperature measurement point, temperature measurement area, and temperature measurement line. Tap the touch screen. Click the temperature measurement mode icon on the touch screen, and the following interface appears.
Color code switching interface According to the display requirements of the target scene, directly click the corresponding color bar on the touch screen to switch to the selected color bar. 4.4 Image adjustment This function is used for manual/automatic mode selection of image adjustment. Click on the touch screen to pop up the main menu. Click on the touch screen to pop up the ICONS of automatic /manual mode as shown below. Click the mode icon to select, and switch to the selected mode.
Image adjustment interface 4.5 Image Storage This feature is used to save images in JPG format. Tap the touch screen and tap the photo icon . Click on the touch screen to save the current image directly. Photo interface 4.6 Image playback This function is used to browse and play back the saved image file. Click the playback icon on the touch screen to pop up the picture library interface, as shown below. Click the corresponding folder to open the folder, click the icon to delete the folder.
Photo gallery interface 4.7 System Settings This function is used to set various parameters of thermal imager, including temperature measurement parameter setting, temperature measurement function setting, network setting, storage setting, alarm setting, device setting, etc. Click the touch screen to pop up the main menu. Click the setting icon on the touch screen to pop up the system setting menu interface, as shown below. System Setting interface 4.7.
Temperature measurement parameter setting menu Temperature measurement gear setting: The temperature gear can be switched. Radiation coefficient setting: You can select the emissivity value of the target through the touch screen. Ambient temperature setting: You can select the ambient temperature by touching the screen. Background temperature setting: You can select the desired background temperature value by touching the screen.
Temperature measurement setting menu Auto-zero interval: You can select the time interval to be zero-adjusted by touching the screen. Auto Enhance Mode: On/Off can be selected via touch screen. High and low temperature points of the temperature measurement line: You can set the display conditions of the high and low temperature points. High and low temperature points in the temperature measurement area: You can set the display conditions of the high and low temperature points. 4.7.
4.7.4 Storage settings In the storage settings menu, there are image storage format settings, memory card capacity display, and format settings. Storage settings menu Image storage settings: You can set a separate JPG format, or you can set an associated visible light format. Memory Card Capacity: Displays the available memory capacity. Format: You can format the memory card. 4.7.
Alarm Settings Menu Temperature alarm mode: On/off can be selected by touch screen. Alarm type: High /low temperature alarm can be selected by touch screen. Alarm temperature: The alarm temperature threshold can be selected through the touch screen. Alarm linkage interval: The alarm linkage interval can be selected by touching the screen. Alarm buzzer: Alarm buzzer on/off can be selected by touch screen. 4.7.
Language and time settings: you can choose the time system, you can choose the date system, time settings, distance units, temperature units. Brightness setting: You can slide the screen to adjust the brightness. Shutdown time setting: you can choose the shutdown time 5 minutes, 30 minutes, 60 minutes, and never. Sleep time setting: you can choose the sleep time 5 minutes, 30 minutes, and never. Screen rotation lock settings: Screen rotation lock can be selected to be on/off.
5 RFQ If you encounter problems with the camera, use the table below for troubleshooting. If the problem cannot be solved, please disconnect the power and contact the maintenance department of our company. Reasons and solutions fault phenomenon Thermal imager failed to start →Charge the device. Thermal imager automatically shuts down The battery runs out of power. The battery runs out of power. →Charge the device. The device is set to be powered off. →Select "never" here.
Appendix A Emissivity of common materials (for reference only) Material name Surface condition Temperature(℃) Emissivity(ε) non-oxidizing 100 0.20 oxidation 100 0.55 polished brown 20 0.40 matt 38 0.22 oxidation 100 0.61 severely oxidized 20 0.78 oxidation 100 0.74 rust 25 0.65 oxidized 200 0.64 not oxidized 100 0.21 hairy 25 0.94 polished 38 0.28 nickel oxidized 200 0.37 stainless steel oxidation 60 0.85 steel oxidation at 800°C 200 0.
FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.