User's Manual
2
3.Specifications
1. Frequency: Support 433MHz, 125KHz reception.
2. Working voltage: 3.7VDC.
3. Working temperature and humidity: 5 ℃ -40 ℃, 0-90% RH.
4. Atmospheric pressure: 860hPa-1060hPa
5. Size, length * width * height = 79mm * 32mm * 12mm.
6. Equipment battery capacity: 3.7VDC, 50mAh
7. Charging interface: TyPC.
8. Charging power supply: input 100-240VAC, 50 / 60Hz, 0.15A; output 5VDC, 1A
4.Installation
This product is divided into upper and lower parts. The upper part is a stretchable
built-in drawstring and a clip that clips on the clothes. The lower part is the place
where the active labels and passive labels placed. The side is equipped with an alarm
button and TYPC charging interface, and the bottom is a hanging hole. The upper and
lower parts are connected by a lanyard. When the door is opened, the card can be
easily swiped by the lanyard.
Functions,
1. One-touch alarm function,there is an alarm button on the label. Medical staff can
press the call alarm in case of emergencies. When pressed, the charging indicator will
flash to indicate that a call signal has been sent.
2. Card access control function,built-in passive labels, drop down alarm module can
open the door controlled by RFID.
3. Hanging function, the lower part of the label should be set into hanging, which can
be used to hang the sign worn by the personnel (print the information of medical
personnel) on it.
4. Positioning function, The positioning signal is automatically sent to the server
according to the locator, and the server draws a trajectory diagram according to the
positioning signal.