Datasheet

CHAPTER 3
TCID commands
24 Vpacket 5100/6100 Series H.323 Telephony
Setting the seize detect parameter
You can set the seize detect parameter by issuing the set tcid [tcid] fxsls seize_detect
command. This command applies only to models with FXS voice interface ports.
Syntax: set tcid [tcid] fxsls seize_detect <value in ms>
Argument:
value in ms
Example:
In this example, the seize detect is set to 3 ms.
Setting the originator clear detect parameter
You can set the originator clear detect parameter by issuing the set tcid [tcid] fxsls
orig_clear_detect command. This command applies only to models with FXS voice interface
ports.
Syntax: set tcid [tcid] fxsls orig_clear_detect <value in ms>
Argument:
value in ms
Example:
In this example, the clear originator detect parameter is set to 5 ms.
telephony# set tcid 2 fxsls seize_detect 3
OK
telephony#
telephony# set tcid 2 fxsls orig_clear_detect 5
OK
telephony#