Instruction manual

DNE4500-P-6-AC and DNE4500-P-6-DC
6-Port DS3 Network Extender Provider Units: AC and DC Versions
1.0 INSTALLATION
1.1 Unpack and Inspect the Equipment
The following components should be included:
If there is visible damage, do not attempt to connect the device; contact Customer Support at 1-877-638-
2638 (001-603-427-0600 for international customers) or support@NetToNet.com.
1.2 Select the Installation Site
The maximum recommended ambient temperature for the DNE4500-P-6 is 50° Celsius (122° Farenheit).
1.2.1 Tabletop Use
Affix the (4) provided rubber bumpers to the bottom corners of the unit to provide surface grip.
Ensure that the DNE4500-P-6 is placed such that the cables will not become a tripping hazard or
pull loose from the unit.
1.2.2 Rack Installation
Using a Phillips Screwdriver, attach the (2) rack mount brackets to the sides of the DNE4500-P-6
with the (10) bracket screws provided. Mount the chassis to the rack using one of the two provided
sets of (4) rack mount screws (whichever size fits the rack being utilized). Check the rack for
stability, ensuring that installation of the DNE4500-P-6 has not caused the rack to become top-
heavy.
Installation Instructions
C
AUTION
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling
this equipment.
1 DNE4500-P-6 10 #6 Phillips Rack Mount Bracket Screws
4 Rubber Bumpers 4 #12 Phillips Rack Screws
1 Power Cord (AC Versions only) 4 #10 Phillips Rack Screws
2 Rack Mount Brackets 1 Installation Instruction manual
C
AUTION
Do not block power supply vents or otherwise restrict airflow around the DNE4500-P-6.