Specifications

3-54 Reference Guide
Model No.
Running Head
Testing Voice Cross-Connects System Configuration and Operation
PATTERN
The Pattern parameter allows you to choose a test pattern to be transmitted as PCM data on
the selected side of the circuit. The options are
off
,
all 0
(zero),
all 1
(one),
m_oos
(multiplexer
out of synchronization),
1:1
(a 1 followed by a zero and then another 1),
1:7
(a zero followed
by a 1 and seven zeros, then another 1),
lpbk
(loopback),
300 Hz
(300 Hz tone),
1KHz
(1 kHz
tone) and
3KHz
(3 kHz tone). Since Tx ABCD only changes signaling bits, this option allows
you to choose the test pattern. You can send a different pattern toward either side of the circuit.
Mon Tx ABCD
The Monitor Transmit ABCD bit information field shows the ABCD bit pattern being
transmitted on the outbound circuit. You can change it by using the
set
command.
This
parameter is for information only.
Mon Rx ABCD
The Monitor Receive ABCD bit information field allows observe the bit pattern being received
on the inbound circuit.
This parameter is for information only; you cannot change it.
CONVERSION
The Conversion information field shows users the conversion setting selected from the
cross-connect screen. The possible values are
no
(no conversion),
sig
(signaling is converted,
but not the PCM),
pcm
(PCM is converted, but not the signaling) and
p&s
(both signaling and
PCM are converted).
This parameter is for information only; you cannot change it.
TYPE
The Type information field show you the type of circuit (
v
for voice or
v&
s for voice and
signaling).
WAN STATE
The WAN State information field shows the current status of the port. The possible values are
stdby
,
actv
,
test
(the user is actively controlling the circuit),
OOS
(WAN port is Out of
Service), and
CGA
(WAN port has a CGA alarm).
This parameter is for information only; you
cannot change it.