Specifications

B-16
Reference Guide
Model No.
Running Head
SR TS overlapping.
The subrate circuit assigned does not allow enough space for a previously assigned circuit on
the same subrate time slot. For example, if you have a 19.2 kbps device on subrate time slot 1
in b-5 framing, you cannot assign another 19.2 kbps circuit to subrate time slot 2, because the
circuit on 1 actually occupies subrate time slots 1 and 2. You must therefore assign that other
circuit to subrate time slot 3 or 4.
Switch request sent to card.
The system has sent your redundancy switchover command to the associated card.
Switchover must be made from the primary WAN.
You cannot switch to a redundant WAN port from another redundant WAN port. You can only
switch from a primary port to a redundant port.
Test function is not available.
The selected test is not available on the current card.
Test in progress. No changes from this screen.
You cannot change any settings in this screen while a card test is in progress.
Test is not available in slc96.
You cannot perform this test on an slc96 WAN port.
This option not available on INTF-2.
You cannot perform this action on the current Interface card.
Timeslot has different framing.
You cannot assign different subrate framing to the same WAN time slot. For example, if you
have a port with b-5 framing on one WAN time slot, you cannot assign a different port with