USER MANUAL Model:F01
Catalogue I. Introduction 1.Technical Parameter......................................................................................1 2.Private Lock..................................................................................................2 3.Backup Key...................................................................................................3 4.Initialization..................................................................................................3 II. Installation Guide 1.
I. Introduction 1. Technical Parameter 4pcs 1.5V AA dry batteries (No include) Battery Type Rechargeable batteries are not recommended, because most rechargeable battery's voltage is 1.2V. Working Voltage 4.5~6v Unlock Ways Fingerprint, Password, Access Card, key Scanner Type LED 3D Live fingerprint sensor FRR, FAR ≤1%,≤0.
2. Private Lock Private mode Only the administrators can unlock it by password, fingerprint,card and backup key. General mode Every added users can unlock it by password, fingerprint,card and backup key.
3. Backup Key Remove the cover cap (2 ways). Method 1: Press the end of the outer handle to pry up the cap. Method 2: Insert a needle into the little hole to push the cap off. Insert the key and turn right 90 degree. Press down the handle to open door. Notice: Please put the backup keys in other place. 4.Initialization Remove the battery cover and press the “SET” button for 5 seconds, lock will sound a short beep, and the screen shows “Initializing.
II. Installation Guide 1. Change Handle Direction Change the Handle to the direction that you need. Use the L wrench which in the accessories bag to remove the hex socket screw and change the direction.
2.Overview 1. Outer Handle 5. 2. Outer Lock Square Spindle 6. PVC Sheet 10. Metal Plate 11. Inner Lock 3. Screws Pillar 4. Data Wire 7. Latch 8. Strike Plate 9.Bottom Case 12. Battery Cover 5 13.
3.Installation Diagram 3.1 Install the latch 1.Adjust the length of the latch according to the distance from the door hole center to the door edge.(60mm or 70mm) 2.Insert the latch in the hole and tighten screws. 3.Install the bottom case and strike plate on door frame.
3.2 Install the outer lock with square spindle 1.Select the suitable square spindle that fit your door thickness. (shorter : 35~45mm; longer: 45~55mm) 2.Find the little pin in the accessories bag. Install the square spindle, through the little hole with the pin to fixed the spindle on the outer lock.Bend the bottom of the little pin to hold it in place. (Please be sure align the position of the little hole) 3.3 Get the metal plate 1. Find the inner lock and take off the battery cover. 2.
3.5 Install the metal plate 1.Select the suitable screws that fit your door thickness. (shorter : 35~45mm; longer: 45~55mm) 2.Install the metal plate to the door and tighten these 3 screws. 3.6 Install the inner lock 1.Connect the data cable to the inner lock. 2. Install the inner lock on the metal plate and fasten with 3 short screws to fix it on the door. 3. Install 4pcs AA dry batteries.
III.
1. Create User 1.1 Create Admin Create First Administrator User Step 1. Into the option menu Method 1: First touch and then touch administrator by pressing initial password 123456 + on the keypad, then please verify . Or method 2: Remove battery cover and press SET button.Then please verify administrator by pressing initial password 123456 + . ↓ Step 2. Select “ 1. Create user” Press “1” into option. ↓ Step 3. Select “ 1. Create admin” Press “1” into option. ↓ Step 4.
The system will give each user a ID number in sequence. Administrators can use the ID number for user management. Follow the instructions of the screen and voice, you can register 9 Admin users with finger print, access cards or password. Note: If you want to add other administrator user next time, please use the administrator user information that you have set to verify administrator because the initial password is invalid after you have set the administrator user. 1.2 Create Normal User Step 1.
Step 4. Register finger, password or access card Finger print: press the same fingerprint, for 3 times. Password: press 4~12digits password and key, for twice. Access card: put a access card close to the keypad, for 1 time. After you create the first normal user, system will automatically proceed to register the next user. You can continue to register more or touch to cancel it. The system gives each user a ID number in sequence. Administrators can use the ID number for user management. 1.
2. Edit User Step 1. Into the option menu Method 1: First touch and then touch on the keypad, verify administrator with the administrator user information (fingerprint, card or password) that you have set. . Or method 2: Remove battery cover and press SET button.Then please verify administrator with the administrator user information (fingerprint, card or password)that you have set. ↓ Step 2. Select “ 2. Edit User” You will into edit user menu. 1. User Blacklist 2. Delete by ID 3. Delete by Type 4.
2.3 Delete by Type Press“3”and you will get into the delete by type menu. 1.Fingerprint 2. Password 3. Card Press“1”or“2”or“3”to delete all normal users which in this unlock way. Notice: Administrators can’t be deleted in this way. 2.4Clear User (delete all) Press“4” and confirm by press , all normal users will be deleted. Notice: Administrators can’t be deleted in this way. 3.System settings Step 1.
3.1 Date Time Press“1”, you will get into the date time menu. Enter the date and time, press button to save it. Only 24-hour system. 3.2 Verify Mode Press“2”, you will get into the verify mode menu. 1. Dual Verify [OFF] 2. Finger [ON] 3. Password [ON] 4. Card [ON] Administrator can manage the ways of unlock. You can active or close these 4 kinds of unlock ways. Dual verify will greatly improve room’s safety level. It mean you have to verify any 2 different normal users for one time to unlock it.
In “User Limit [OFF], Passage [ON]” mode. Any user or administrator verify it first, then the lock will get into the Passage Mode. Anyone can open it without verify. Active One-time Passage Mode (Passage [OFF] Only) In “User Limit [ON] Passage [OFF] ” mode, administrator unlock the lock and press the bb button before it lock, system will get into passage mode. Any user verify again can cancel the passage mode.
4.Unlock Records Step 1. Into the option menu Method 1: First touch and then touch on the keypad, verify administrator with the administrator user information (fingerprint, card or password) that you have set. Or method 2: Remove battery cover and press SET button.Then please verify administrator with the administrator user information (fingerprint, card or password) that you have set. ↓ Step 2. Select “ 4. System Setting” You will get into the system setting menu. 1.Query by Time 2. Query by Type 3.
Ⅳ. Others 1. Low Power When the battery voltage is too low, the lock will warn you by voice and display “Low Power ×”. You can still access about 100 times. Please change the batteries in time. 2.Emergency Power Supply You can use any power bank with a micro USB wire to supply the lock by its USB port. 3.Alarms Input wrong password for 5 times, system will be locked up and display“System is locked”. Buzzer sounds a long-beep for 5 sec.
ID User Name ID User Name ID 001 admin 026 051 002 admin 027 052 003 admin 028 053 004 admin 029 054 005 admin 030 055 006 admin 031 056 007 admin 032 057 008 admin 033 058 009 admin 034 059 010 035 060 011 036 061 012 037 062 013 038 063 014 039 064 015 040 065 016 041 066 017 042 067 018 043 068 019 044 069 020 045 070 021 046 071 022 047 072 023 048 073 024 049 074 025 050 075 19 User Name
FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference. (2)This device must accept any interference received, including interference that may cause undesired operation. 2. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.