Operation Manual
7
2
Use the + and -buttontosetthedesiredtemperature,from13to30ºC.
3
The temperature icon
will stop blinking and the current room temperature will
appear after the desired temperature is set.
4
Oncetheroomtemperatureexceedsthesettemperatureforover10seconds,the
heater will stop heating and the temperature icon
will blink.
5
Oncetheroomtemperaturedrops1ºCbelowthesettemperature,theheaterwill
start heating again and the temperature icon on the display will stop blinking.
OVERHEAT PROTECTION
Thisappliancehastwolevelsofoverheatprotection:
1. Automatic thermal cut-off
Switches off the heater in the event of overheating or malfunction and resets once
the temperature drops to a normal level
2. Thermal fuse
Intheeventthattheautomaticthermalcut-offfailstooperate,theheaterhasa
further safety device. This is a non-resettable switch which will require the unit be
returned to an approved service centre for replacement.
Ifoverheatingormalfunctionsoccuronaregularbasis,returntheheatertoanapproved
service centre for examination.
TIMER SETTING
AUTO OFF
Make sure to set the desired temperature prior to setting the timer, so that the
heater will shut off at the desired temperature setting.
With the Auto OFF timer setting you can decide the time that the heater should
automatically switch of.
1
Keep pressing the Mode button until the timer icon blinks. The Auto Off icon will
also appear.
2
Use the + and - buttons to set the heater operation time between 1 and 24 hours
(defaultis10hours).
3
The heater will automatically turn off when the set timer setting runs out.
G
NOTE!
When both desired temperature and timer off function have been activated, the
heater will switch on and off per the set temperature setting and will stop
operating once the programmed timer setting has been reached.
4
7